DIRECT BUILD, INC. | B= | C | 06/13/2014 | | CHRISM | CHRISM | | B= | C | 4757591 | DIRECT BUILD, INC. | B= | R | 06/12/2014 | CO detectors missing | CHRISM | CHRISM | | B= | R | 4756968 | DIRECT BUILD, INC. | BLA | C | 02/26/2014 | | ED | ED | | BLA | C | 4693532 | DIRECT BUILD, INC. | BIN | C | 02/26/2014 | | ED | ED | | BIN | C | 4693521 | DIRECT BUILD, INC. | BLA | P | 02/24/2014 | extend electric boxes | CHRISM | CHRISM | | BLA | P | 4691706 | DIRECT BUILD, INC. | BFR | C | 02/21/2014 | | CHRISM | CHRISM | | BFR | C | 4690847 | DIRECT BUILD, INC. | BSP | P | 02/19/2014 | portal frame ok | CHRISM | CHRISM | | BSP | P | 4689417 | DIRECT BUILD, INC. | BSP | P | 02/13/2014 | front porch and posts ok, rear porch and porch ok | CHRISM | CHRISM | | BSP | P | 4686606 | DIRECT BUILD, INC. | BFD | C | 12/27/2013 | soils on file | ED | ED | | BFD | C | 4663182 | DIRECT BUILD, INC. | BFN | C | 12/27/2013 | engineer inspection letters for footing / foundation , design on file | ED | ED | | BFN | C | 4663179 | DIRECT BUILD, INC. | BFT | C | 12/27/2013 | 1500 psf | ED | ED | | BFT | C | 4663176 | DIRECT BUILD, INC. | BFN | P | 12/26/2013 | AUTHORIZED INSPECTION BY ENGINEER | JESSICA | JESSICA | JESSICA | BFN | P | 4662617 | DIRECT BUILD, INC. | BFT | P | 12/26/2013 | AUTHORIZED INSPECTION BY ENGINEER | JESSICA | JESSICA | JESSICA | BFT | P | 4662616 | TOP ELECTRIC, INC. | E= | C | 05/12/2014 | | MATTHEW | MATTHEW | | E= | C | 4736883 | TOP ELECTRIC, INC. | E= | R | 05/02/2014 | install inter-system bond terminal, need #10 equipment ground to a/c.\, provide means to check OH door outlet and outlet in mech room ceiling, secure front deck outlet, replace nm to outlet on pole, need #8 to spa motor, no micro circuit?-------- 30 amp a/c | MATTHEW | MATTHEW | | E= | R | 4732053 | TOP ELECTRIC, INC. | ES | C | 05/02/2014 | Residential Overhead: 200 amp 3/w: new res------meter is set and sealed | MATTHEW | MATTHEW | | ES | C | 4732052 | TOP ELECTRIC, INC. | ER | C | 02/20/2014 | finished basement, no mcc's, 8-3 nm to cooking equipment----------- 1/0 al sub-panel not breakered | MATTHEW | MATTHEW | | ER | C | 4690374 | TOP ELECTRIC, INC. | EUG | C | 02/13/2014 | 4/0 al feeder ok | MATTHEW | MATTHEW | | EUG | C | 4686746 | NOACH HEATING, INC. | H= | C | 05/06/2014 | correction made | TED | TED | | H= | C | 4733543 | NOACH HEATING, INC. | H= | P | 04/03/2014 | Discharge pipe required off t&p valve to water heater. Gas not complete to water heater. Shortest route possible required on vent connector to water heater. Rest ok Notes-- AC complete.. Louver door. | JEFFL | JEFFL | | H= | P | 4714462 | NOACH HEATING, INC. | HC | C | 02/20/2014 | RELEASE METER | TED | TED | | HC | C | 4690100 | NOACH HEATING, INC. | HRR | C | 02/20/2014 | theater room to be unfinished as is one basement bedroom, other corrections made | TED | TED | | HRR | C | 4690096 | NOACH HEATING, INC. | HRR | R | 02/19/2014 | per plan--missing supply and return in theater room, missing return in both basement bedrooms, also have electric light boxs in return in basement ceiling, seal missed joint basement ceiling, connect vent on basement bath fan, note: finished basement, a/c rough, outside air to return, duct design | TED | TED | | HRR | R | 4689396 | KAMPP-L ENTERPRISES, INC. | HI | C | 02/14/2014 | 10# test ok. 1 1/4" main to furn, w/h, 2-fp, dryer, c-top, bbq. | MICHAELS | MICHAELS | | HI | C | 4687634 | KAMPP-L ENTERPRISES, INC. | P= | C | 05/21/2014 | POTABLE WATER CERTIFICATE TO SCANNING | GABE | GABE | | P= | C | 4742844 | KAMPP-L ENTERPRISES, INC. | P= | L | 05/16/2014 | LEFT DOOR TAG | GABE | GABE | | P= | L | 4740121 | KAMPP-L ENTERPRISES, INC. | P= | P | 05/12/2014 | NO HOT WATER, NEED POTABLE WATER CERTIFICATE FOR FINAL | GABE | GABE | | P= | P | 4736645 | KAMPP-L ENTERPRISES, INC. | PTO | C | 02/18/2014 | finished basement | JOEL | JOEL | | PTO | C | 4688556 | HOMEOWNER | PWO | C | 02/14/2014 | | TIM | TIM | | PWO | C | 4687113 | HOMEOWNER | PWO | P | 02/12/2014 | need an approved backflow at an approved location for new yard hydrant | TIM | TIM | | PWO | P | 4686088 | KAMPP-L ENTERPRISES, INC. | PB | C | 01/03/2014 | | TIM | TIM | | PB | C | 4666217 |
|
|