BUILTRITE BUILDERS | B= | C | 09/09/2014 | finished basement, deck in | DALE | DALE | | B= | C | 4812314 |
BUILTRITE BUILDERS | B= | P | 09/08/2014 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet. no insulation at attic -- Schedule a new Building Final when above items are complete. | DALE | DALE | | B= | P | 4811546 |
BUILTRITE BUILDERS | BIN | C | 06/24/2014 | | CHRISM | CHRISM | | BIN | C | 4764556 |
BUILTRITE BUILDERS | BFR | C | 06/24/2014 | | CHRISM | CHRISM | | BFR | C | 4764558 |
BUILTRITE BUILDERS | BLA | C | 06/24/2014 | | CHRISM | CHRISM | | BLA | C | 4764554 |
BUILTRITE BUILDERS | BFR | P | 06/20/2014 | add 2x4 to all lateral be=racing installed with 1x4, missing laterals art C10,C09,C08,C07,C06,C05,, patch hole in roof , missing roof jack, finished basement, ok to insulate | ED | ED | | BFR | P | 4762737 |
BUILTRITE BUILDERS | BSP | P | 04/01/2014 | front porch and posts ok, deck piers ok | CHRISM | CHRISM | | BSP | P | 4712673 |
BUILTRITE BUILDERS | BFD | C | 02/10/2014 | | CHRISM | CHRISM | | BFD | C | 4684776 |
BUILTRITE BUILDERS | BFD | R | 02/05/2014 | voids found in water proofing, needs to be sprayed equally along foundation wall around all habitable areas / habitable drain, good / excavation observation on file | JEREMYC | JEREMYC | | BFD | R | 4683425 |
BUILTRITE BUILDERS | BFI | C | 02/05/2014 | 2" rigid insulation, R-10 installed under walk out area | JEREMYC | JEREMYC | | BFI | C | 4683421 |
BUILTRITE BUILDERS | BFT | C | 02/05/2014 | footer & eufer observation on file | JEREMYC | JEREMYC | | BFT | C | 4683420 |
BUILTRITE BUILDERS | BFN | P | 02/05/2014 | need compaction letter for 24" pad found on cutline / foundation design & rebar observation on file / 1.5" float | JEREMYC | JEREMYC | | BFN | P | 4683416 |
POSITIVE ELECTRIC, LLC | E= | C | 09/04/2014 | no a/c | MATTHEW | MATTHEW | | E= | C | 4810058 |
POSITIVE ELECTRIC, LLC | E= | R | 09/03/2014 | enclose master closet light, correct basement bedroom closet light clearance, need gfci protection within 6' of wet bar sink, gfci protection can't be behind fridge at wet bar, correct spacing at basement slider, where's pantry light switch? | MATTHEW | MATTHEW | | E= | R | 4809132 |
POSITIVE ELECTRIC, LLC | ER | C | 05/23/2014 | check spacing at basement slider at final | MATTHEW | MATTHEW | | ER | C | 4745087 |
POSITIVE ELECTRIC, LLC | ER | R | 05/21/2014 | TC CABLE STILL NOT IN CONDUIT--------VERIFY OUTLET SPACING ON BASEMENT SLIDER?? | BRIAN | BRIAN | | ER | R | 4743086 |
POSITIVE ELECTRIC, LLC | ES | C | 05/16/2014 | Residential Overhead: 200 amp 3/w: new res---- meter is set; need seal | MATTHEW | MATTHEW | | ES | C | 4740522 |
POSITIVE ELECTRIC, LLC | ER | R | 05/16/2014 | wire hanging in both main level bathrooms, need metal box for mc whip at basement fireplace, 3-wire at wet bar neutrals not made up, verify spacing at basement door not installed, tc cable for well ran thru basement needs to be in conduit------------- finished basement, 2-20, #6al | MATTHEW | MATTHEW | | ER | R | 4740515 |
POSITIVE ELECTRIC, LLC | EUG | C | 02/25/2014 | service lateral from pole to house | MATTHEW | MATTHEW | | EUG | C | 4692845 |
MAJOR HEATING AND AIR CONDITIONING, INC. | H= | C | 09/05/2014 | correction made | TED | TED | | H= | C | 4810441 |
MAJOR HEATING AND AIR CONDITIONING, INC. | H= | P | 09/04/2014 | Need M/A to laundry. Rest ok.
| MARK | MARK | | H= | P | 4809592 |
MAJOR HEATING AND AIR CONDITIONING, INC. | HC | C | 06/19/2014 | RELEASE METER | TED | TED | | HC | C | 4761494 |
MAJOR HEATING AND AIR CONDITIONING, INC. | HRR | C | 06/19/2014 | correction made | TED | TED | | HRR | C | 4761491 |
MAJOR HEATING AND AIR CONDITIONING, INC. | HRR | R | 06/17/2014 | need 2nd bath fan and vent in master bathroom over tub area, note: finished basement, geo-themo air handles, sealed combustion water heater | TED | TED | | HRR | R | 4759921 |
MAJOR HEATING AND AIR CONDITIONING, INC. | HRR | R | 06/16/2014 | no plan found again, waive trip fee this time | TED | TED | | HRR | R | 4758792 |
MAJOR HEATING AND AIR CONDITIONING, INC. | HRR | T | 06/11/2014 | PAID (REC#1201072) not ready, no design plan or permit card found, need to insulate bath fan vents in attic, has geo-thermo piping been installed ? if so there was no inspection | TED | TED | | HRR | T | 4755792 |
RIDGEVIEW PLUMBING | HI | C | 05/22/2014 | 1'' 1-outlet in mech. room (?), fireplace, range, dryer, bbq | TED | TED | | HI | C | 4744155 |
RIDGEVIEW PLUMBING | P= | C | 09/04/2014 | POTABLE WATER CERT TO SCANNING . NOTE: FINISHED BASEMENT . PVB INSTALLED | GABE | GABE | | P= | C | 4809657 |
RIDGEVIEW PLUMBING | PTO | C | 05/22/2014 | finished basement | TED | TED | | PTO | C | 4744150 |
RIDGEVIEW PLUMBING | PWO | C | 03/07/2014 | | DICK | DICK | | PWO | C | 4699051 |
RIDGEVIEW PLUMBING | PB | C | 02/14/2014 | | JOEL | JOEL | | PB | C | 4687715 |