HOMEOWNER | B= | C | 10/20/2014 | | DALE | DALE | | B= | C | 4837813 |
HOMEOWNER | BIN | C | 04/11/2014 | | CHRISM | CHRISM | | BIN | C | 4719040 |
HOMEOWNER | BFR | C | 04/03/2014 | | CHRISM | CHRISM | | BFR | C | 4714089 |
HOMEOWNER | BFR | P | 04/02/2014 | no truss details on site | CHRISM | CHRISM | | BFR | P | 4713484 |
HOMEOWNER | BSP | P | 03/21/2014 | Front porch frame and posts ok | NICK | NICK | | BSP | P | 4706524 |
HOMEOWNER | BSP | P | 03/11/2014 | front porch piers ok | CHRISM | CHRISM | | BSP | P | 4700306 |
HOMEOWNER | BSP | T | 02/28/2014 | PAID (REC#1183089) PLAN SPLICE FEE: $50 by: TCRIPPEN for Mechanical: NEW SPLICE | TCRIPPEN | TCRIPPEN | | BSP | T | 4695262 |
HOMEOWNER | BSP | T | 02/28/2014 | PAID (REC#1183089) PLAN SPLICE FEE: $50 by: MICHAEL for Construction: Revise IECC | MICHAELA | MICHAELA | | BSP | T | 4694753 |
HOMEOWNER | BSP | P | 01/22/2014 | inverted hangers on cants | CHRISM | CHRISM | | BSP | P | 4675806 |
HOMEOWNER | BFD | C | 01/21/2014 | soils on file drain crawl | CHRISM | CHRISM | | BFD | C | 4674509 |
HOMEOWNER | BFT | C | 01/21/2014 | eng report on file | CHRISM | CHRISM | | BFT | C | 4674508 |
HOMEOWNER | BFD | P | 01/09/2014 | drain crawl ok, need copy of soils and eng report for footer inspection | CHRISM | CHRISM | | BFD | P | 4669005 |
HOMEOWNER | BFN | C | 12/30/2013 | design and open hole on file, soils at drain | CHRISM | CHRISM | | BFN | C | 4664279 |
HOMERUN ELECTRONICS, INC. | E= | C | 07/24/2014 | outlet for generator removed (future generator hook up) | MATTHEW | MATTHEW | | E= | C | 4783561 |
HOMERUN ELECTRONICS, INC. | E= | R | 07/22/2014 | corrections still not done; i talked to contractor------ afci protection is for x-mas outlet in closet | MATTHEW | MATTHEW | | E= | R | 4781806 |
HOMERUN ELECTRONICS, INC. | E= | R | 07/16/2014 | corrections not made---- outlets still loose, missing handle ties, need pin outlet for generator, bonding for spa still incorrect------ need to check afci protection at re-inspect | MATTHEW | MATTHEW | | E= | R | 4778380 |
HOMERUN ELECTRONICS, INC. | E= | R | 07/11/2014 | Bonding at jetted tub incorrect---------- Use faceless GFCI for jetted tub------------- AC breaker max size is 25 amp------------- AFCI per 2011 nec------- Exterior outlets too loose------------ Generator outlet miswired and no interlock-----------Handle ties------- | JOSEPH | JOSEPH | | E= | R | 4775696 |
HOMERUN ELECTRONICS, INC. | ER | C | 03/26/2014 | | MATTHEW | MATTHEW | | ER | C | 4709331 |
HOMERUN ELECTRONICS, INC. | ES | C | 03/25/2014 | Residential Underground: 200 amp 3/w; new res--------meter set; need seal | MATTHEW | MATTHEW | | ES | C | 4708192 |
HOMERUN ELECTRONICS, INC. | ER | R | 03/25/2014 | missing wire to back exterior box, missing connector at exterior bell box (remove low volt cable from same box), nail plate garage, staple nm above garage doors, missing outlet in living room bo return air, missing outlets upstairs (under switch 15' left of stairs, in both bedrooms; spacing starts outside of hallways), wire fireplace----------3-20, #6al | MATTHEW | MATTHEW | | ER | R | 4708184 |
HOMERUN ELECTRONICS, INC. | EUG | C | 03/25/2014 | service lateral from ped to home; contractor tied to existing service lateral----------------- #2al feeder to backyard; call me in the am to let me know what this is for | MATTHEW | MATTHEW | | EUG | C | 4708179 |
HOMEOWNER | H= | C | 10/10/2014 | CORRECTIONS MADE . | GABE | GABE | | H= | C | 4832858 |
HOMEOWNER | H= | R | 10/01/2014 | need louver door or no door to laundry room that has mech. room, (solid door at this time) for combustion air and dryer make up air, install t&p drain, install water heater pan drain, need 1'' clearance around b vent at ceiling from dry wall, need supplys and return in crawlspace, note: a/c installed on one furnace | TED | TED | | H= | R | 4826487 |
WRIGHT TOTAL INDOOR COMFORT | HC | C | 04/01/2014 | RELEASE METER | JEFFL | JEFFL | | HC | C | 4712477 |
WRIGHT TOTAL INDOOR COMFORT | HRR | C | 04/01/2014 | Corrections made. | JEFFL | JEFFL | | HRR | C | 4712474 |
HOMEOWNER | HI | C | 04/01/2014 | Correction made.. | JEFFL | JEFFL | | HI | C | 4712472 |
HOMEOWNER | HRR | R | 03/31/2014 | Vents exceed maximum allowable exposed in unconditioned space in crawl space and attic. Insulate per manufacturers specs. Rest ok. | JEFFL | JEFFL | | HRR | R | 4711869 |
WRIGHT TOTAL INDOOR COMFORT | HRR | P | 03/28/2014 | Framing not complete at fireplace. Heat shield required around b vent in attic. Seal plenums in crawl space. Provide install instructions for furnace to determine if vent is sized appropriately for length. | JEFFL | JEFFL | | HRR | P | 4711092 |
HOMEOWNER | HO | C | 03/21/2014 | Outside gas ok. 10 lb test on #15 gauge ok.
| MARK | MARK | | HO | C | 4706472 |
HOMEOWNER | HO | R | 03/20/2014 | Test on house line was low. 7.5 on a #30 gauge. Test on supply from meter is invalid. 15 lbs on 300lb gauge. Need to see 10lbs on a 30lb gauge or 60 on a 100 gauge. Note: 1" poly from meter to house (7145 only) is good. Ok to cover from trench Y to house only. Note: Neighbor's gas pipe that will share a portion of the trench is not in the ground yet. | MARK | MARK | | HO | R | 4705965 |
HOMEOWNER | HRR | R | 03/19/2014 | changed from hd inspection to an hrr, not ready to many items to list, reinspect all | TED | TED | | HRR | R | 4705467 |
HOMEOWNER | HI | P | 03/19/2014 | need fireplace installed and gas piping run into cabinet, note: 1 1/4'' 2-furnaces, w/h, dryer, range, fireplace, bbq | TED | TED | | HI | P | 4705460 |
HOMEOWNER | P= | C | 09/29/2014 | NOTE : CRAWL SPACE . PVB INSTALLED . POTABLE WATER CERT TO SCANNING | GABE | GABE | | P= | C | 4824851 |
HOMEOWNER | PTO | C | 03/25/2014 | correction made | TED | TED | | PTO | C | 4708656 |
HOMEOWNER | PTO | P | 03/20/2014 | strap piping in crawl space to code, hub drain s trapped...note need to re-inspect all flashlight died b4 I was done | TIM | TIM | | PTO | P | 4705820 |
HOMEOWNER | PTO | P | 03/19/2014 | need access to crawlspace, wtr lines in garage need to be as high as possible | TIM | TIM | | PTO | P | 4704888 |
HOMEOWNER | PWO | C | 02/26/2014 | | DICK | DICK | | PWO | C | 4693698 |