SUNSET DREAM HOMES, INC | B= | C | 02/20/2015 | | DALE | DALE | | B= | C | 4906485 |
SUNSET DREAM HOMES, INC | B= | R | 02/10/2015 | speakers in garage ceiling need 1hr rating? | DALE | DALE | | B= | R | 4900370 |
SUNSET DREAM HOMES, INC | BIN | C | 08/22/2014 | | DALE | DALE | | BIN | C | 4802376 |
SUNSET DREAM HOMES, INC | BLA | C | 08/14/2014 | | DALE | DALE | | BLA | C | 4796947 |
SUNSET DREAM HOMES, INC | BFR | P | 08/14/2014 | still need foam and firestop | DALE | DALE | | BFR | P | 4796946 |
SUNSET DREAM HOMES, INC | BFR | R | 08/12/2014 | foam and firestop / anchors missing thru-out / 5k at garage door / eng. on hinge point at garage / FHA plate at plumbing / 3 2x6 under girder at garage / cut lip at stairs / strap stair landing and anchor joists / 3 2x6 under porch ends / remove blocks under floating walls / eng. for beam, no pocket / adding electric after ER | DALE | DALE | | BFR | R | 4795692 |
SUNSET DREAM HOMES, INC | BSP | P | 07/29/2014 | porch frames ok | DALE | DALE | | BSP | P | 4785845 |
SUNSET DREAM HOMES, INC | BSP | T | 07/17/2014 | PAID (REC#1208582) PLAN SPLICE FEE: $50 by: THOMASL for Mechanical: Changed design of mechanical system. | THOMASL | THOMASL | | BSP | T | 4778607 |
SUNSET DREAM HOMES, INC | BSP | P | 06/16/2014 | deck piers ok | CHRISM | CHRISM | | BSP | P | 4758887 |
SUNSET RIDGE DREAM HOMES | BFI | C | 12/21/2013 | R-10 at walkout | CHRISM | CHRISM | | BFI | C | 4661486 |
SUNSET RIDGE DREAM HOMES | BFD | C | 12/21/2013 | soils on file drain usable isolate and float | CHRISM | CHRISM | | BFD | C | 4661485 |
SUNSET RIDGE DREAM HOMES | BFN | C | 12/21/2013 | design and eng report on file | CHRISM | CHRISM | | BFN | C | 4661484 |
SUNSET RIDGE DREAM HOMES | BFT | C | 12/21/2013 | eng report on file | CHRISM | CHRISM | | BFT | C | 4661483 |
CURTIS ELECTRICAL CONTRACTORS LLC | E= | C | 01/16/2015 | | MATTHEW | MATTHEW | | E= | C | 4886486 |
CURTIS ELECTRICAL CONTRACTORS LLC | E= | R | 01/06/2015 | afci wet bar, dining room light and media closet, gfci 6' from laundry sink and wet bar sink, missing hot tub disconnect, need wr outlet front outlet and outlet on side of garage and upper deck outlets at bbq, missing light on small deck outside of boys room and in-use cover is upside down, need gfci breaker for x-mas outlets, strap flex at furnaces, ground 4 sq box at well, 30 amp breaker too big for 25 amp max a/c, replace white wire at a/c, strap emt in lower garage, install inter-system bond terminal, vacuum needs to be on dedicated circuit (13 amps)------------------ 1 a/c installed---------- 1 a/c pre-wire-------- hot tub pre-wire | MATTHEW | MATTHEW | | E= | R | 4881086 |
CURTIS ELECTRICAL CONTRACTORS LLC | E= | R | 12/18/2014 | not ready------ check panels at time of final | MATTHEW | MATTHEW | | E= | R | 4874702 |
CURTIS ELECTRICAL CONTRACTORS LLC | ES | C | 12/18/2014 | Residential Overhead: 200 amp 3/w: new res------- meter is set need seal | MATTHEW | MATTHEW | | ES | C | 4874692 |
CURTIS ELECTRICAL CONTRACTORS LLC | ER+ | C | 08/15/2014 | 10-2 stub out at a/c location and 6-3ser to garage ok | MATTHEW | MATTHEW | | ER+ | C | 4798115 |
CURTIS ELECTRICAL CONTRACTORS LLC | ER | C | 08/11/2014 | | MATTHEW | MATTHEW | | ER | C | 4794487 |
CURTIS ELECTRICAL CONTRACTORS LLC | EUG | C | 08/11/2014 | pvc from pole to home------ pvc risers not installed; leave open for service inspection | MATTHEW | MATTHEW | | EUG | C | 4794473 |
CURTIS ELECTRICAL CONTRACTORS LLC | ER | R | 08/05/2014 | central vac being installed; contractor needs to tie in outlets--------------------- contractor ran #4cu for ufer to garage area below panel (not tied in and rebar isn't exposed at this time) | MATTHEW | MATTHEW | | ER | R | 4790497 |
CURTIS ELECTRICAL CONTRACTORS LLC | ER | R | 08/01/2014 | run grounding electrode conductor to service; land nm and make up grounds in lower garage -----------finished basement, 1/0al sub-panel, 8-3nm stub out | MATTHEW | MATTHEW | | ER | R | 4788869 |
BRUNO'S HEATING & COOLING | H= | C | 12/29/2014 | correction made | TED | TED | | H= | C | 4878359 |
BRUNO'S HEATING & COOLING | H= | R | 12/24/2014 | vent manual not found, joints not sealed in wall opening to out side, may still need clearance to opening door | TED | TED | | H= | R | 4877646 |
BRUNO'S HEATING & COOLING | H= | R | 12/22/2014 | Still have un approved venting material, trip fee waived. | MICHAELS | MICHAELS | | H= | R | 4876485 |
BRUNO'S HEATING & COOLING | H= | R | 12/18/2014 | Need approved wall thimble for vent, vent termination is within 4' of opening door, improper vent material per manufacturer. | MICHAELS | MICHAELS | | H= | R | 4874671 |
BRUNO'S HEATING & COOLING | H= | P | 12/17/2014 | Need manual for lower garage unit heater venting, vent is against insulation inside wall, remove insulation around b-vent in mech. Note: finished basement, high/low transfer in wall, full a/c on upper level, a/c rough(lineset only) on basement, mantels ok. | MICHAELS | MICHAELS | | H= | P | 4873530 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | HC | C | 10/02/2014 | RELEASE METER | MICHAELS | MICHAELS | | HC | C | 4827437 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | HO | C | 10/02/2014 | 10# test ok. 2lb. 1" poly from road to house. BY FINAL: need letter, reg and labeling. | MICHAELS | MICHAELS | | HO | C | 4827434 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | HI | C | 08/05/2014 | 10 LB. test ok. 1 1/2'' main.. 2 furnace.. 2 water heaters.. 2 fp.. 1 range.. 1 unit heater..1 bbq | JEFFL | JEFFL | | HI | C | 4790835 |
BRUNO'S HEATING & COOLING | HRR | C | 08/05/2014 | Notes-- finished basement. ac rough x 2... Duct design.... Direct vent furnace x 2.. OSA to return. Equipment certs to scanning. | JEFFL | JEFFL | | HRR | C | 4790826 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | P= | C | 01/16/2015 | NOTE : FINISHED BASEMENT , NO IRRIGATION , POTABLE WATER CERT TO SCANNING | GABE | GABE | | P= | C | 4886067 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PTO | C | 08/05/2014 | finished basement, note: well head is in the mech. room in the finished basement, ( need certificate of potable water by final ) | TED | TED | | PTO | C | 4790447 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PB | C | 01/16/2014 | | JOEL | JOEL | | PB | C | 4672964 |