ROCK SOLID DEVELOPMENT LLC | B= | C | 08/19/2014 | All other required Final inspections are complete. (This is a computer generated result) | DALE | DALE | | B= | C | 4799661 |
ROCK SOLID DEVELOPMENT LLC | B= | P | 08/19/2014 | Additional Inspections Required: External Agency Inspection HD= by HEALTHDEPT is not Completed yet. unfinished basement, deck in | DALE | DALE | | B= | P | 4799228 |
ROCK SOLID DEVELOPMENT LLC | BIN | C | 05/12/2014 | | ED | ED | | BIN | C | 4736913 |
ROCK SOLID DEVELOPMENT LLC | BFR | C | 05/12/2014 | items completed, check weld at steel pack above mono post in unfinished basement at final | ED | ED | | BFR | C | 4736907 |
ROCK SOLID DEVELOPMENT LLC | BLA | C | 05/07/2014 | | CHRISM | CHRISM | | BLA | C | 4734463 |
ROCK SOLID DEVELOPMENT LLC | BFR | R | 04/28/2014 | steel shim beam in pocket, t-posts have over 3" of thresd showing, cut plywood at overframe, lateral braces missing B4A and B5, plans call for H9 at all trusses H2.5s installed | CHRISM | CHRISM | | BFR | R | 4728124 |
ROCK SOLID DEVELOPMENT LLC | BSP | P | 03/28/2014 | front and rear porch roofs ok | CHRISM | CHRISM | | BSP | P | 4710696 |
ROCK SOLID DEVELOPMENT LLC | BSP | P | 03/07/2014 | deck and porch piers ok | CHRISM | CHRISM | | BSP | P | 4698851 |
ROCK SOLID DEVELOPMENT LLC | BFI | C | 01/29/2014 | R-7.5 at walkout walls | CHRISM | CHRISM | | BFI | C | 4679834 |
ROCK SOLID DEVELOPMENT LLC | BFD | C | 01/27/2014 | soils on file drain usable isolate and float, need insulation at walkout | CHRISM | CHRISM | | BFD | C | 4678023 |
ROCK SOLID DEVELOPMENT LLC | BFN | C | 01/27/2014 | eng report on file | CHRISM | CHRISM | | BFN | C | 4678022 |
ROCK SOLID DEVELOPMENT LLC | BFT | C | 01/27/2014 | eng report on file | CHRISM | CHRISM | | BFT | C | 4678021 |
ROCK SOLID DEVELOPMENT LLC | BFN | P | 12/23/2013 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFN | P | 4661997 |
ROCK SOLID DEVELOPMENT LLC | BFT | P | 12/23/2013 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFT | P | 4661996 |
MEYER ELECTRIC | E= | C | 08/18/2014 | no a/c | MATTHEW | MATTHEW | | E= | C | 4798783 |
MEYER ELECTRIC | E= | R | 08/15/2014 | gfci outlet at master deck needs to be wr, can't ground well disconnect with sheet metal screw, front outlet still loose and needs arc shield and to be sealed around, seal around exterior lights with gaps | MATTHEW | MATTHEW | | E= | R | 4798233 |
MEYER ELECTRIC | E= | T | 08/11/2014 | PAID (REC#1213896): complete re-inspect--- contractor needs to check house before recall----- partial list: exterior outlets and lights loose, land water GEC, bond well disconnect, ground furnace disconnect and secure furnace disconnect, missing basement smoke detector, install dryer cover plate, 3 ways in mud room and hall off garage are wired wrong, island outlet box installed with screws in side of box, gfci protect outlet at master deck, master deck light buried behind stucco---------- complete re-inspect | MATTHEW | MATTHEW | | E= | T | 4794625 |
MEYER ELECTRIC | E= | R | 08/08/2014 | not ready-- missing lights, inter-system bond, no way to check OH doors, panel cover not knocked out, disposal breaker not labeled----- didn't finish inspecting outside of home and never entered home | MATTHEW | MATTHEW | | E= | R | 4793637 |
MEYER ELECTRIC | ES | C | 04/18/2014 | Residential Underground: 200 amp 3/w: new res----- meter is set--- need seal | MATTHEW | MATTHEW | | ES | C | 4723221 |
MEYER ELECTRIC | ES | R | 04/17/2014 | need gec to water, remove temp and land service lateral in pedestal | MATTHEW | MATTHEW | | ES | R | 4722419 |
MEYER ELECTRIC | ER | C | 04/17/2014 | unfinished basement, 3-20, 1-15, #6al | MATTHEW | MATTHEW | | ER | C | 4722412 |
MEYER ELECTRIC | EUG | C | 04/07/2014 | service lateral from ped to home | MATTHEW | MATTHEW | | EUG | C | 4715709 |
HVAC SOLUTIONS, INC. | H= | C | 08/13/2014 | Final ok. Note: mech rm transfers to Unf. Bsmnt under stairs. No a/c, Has OSA to return. | MARK | MARK | | H= | C | 4795856 |
O.M.A.G.M., INC. | HC | C | 04/18/2014 | RELEASE METER | TED | TED | | HC | C | 4722802 |
O.M.A.G.M., INC. | HO | C | 04/18/2014 | test on old and new under ground piping with new risers at house and meter at road, | TED | TED | | HO | C | 4722801 |
O.M.A.G.M., INC. | HI | C | 04/16/2014 | 1'' furnace, w/h, fireplace, range note: need letter for 2lb system | TED | TED | | HI | C | 4721718 |
O.M.A.G.M., INC. | HO | R | 04/16/2014 | outside under ground p.e. piping from meter at road to house has been covered without an inspection, pot hole it for depth inspection, note: 10lb test on 1 1/4'' raiser at house, need letter for 2lb system | TED | TED | | HO | R | 4721717 |
HVAC SOLUTIONS, INC. | HRR | C | 04/16/2014 | unfinished basement, no a/c, outside air to return, duct design | TED | TED | | HRR | C | 4721714 |
HOGAN MECHANICAL, INC. | P= | C | 08/15/2014 | certificate of potable water to scanning | TED | TED | | P= | C | 4797600 |
HOGAN MECHANICAL, INC. | P= | P | 08/11/2014 | need certificate of potable water, note: unfinished basement | TED | TED | | P= | P | 4794273 |
HOGAN MECHANICAL, INC. | PWO | C | 04/28/2014 | POTABLE WATER CERTIFICATE BY FINAL | GABE | GABE | | PWO | C | 4728008 |
HOGAN MECHANICAL, INC. | PTO | C | 04/11/2014 | CORRECTIONS MADE | GABE | GABE | | PTO | C | 4718677 |
HOGAN MECHANICAL, INC. | PTO | P | 04/10/2014 | NO TEST ON WEST SIDE DWV , LOW TEST ON MASTER DWV . WATER OK | GABE | GABE | | PTO | P | 4717804 |
HOGAN MECHANICAL, INC. | PB | C | 03/18/2014 | | TIM | TIM | | PB | C | 4704514 |