HOMEOWNER | BE | C | 05/17/2016 | | NELIDA | NELIDA | | BE | C | 5200986 |
HOMEOWNER | BLA | C | 08/31/2015 | | BOBF | BOBF | | BLA | C | 5027254 |
HOMEOWNER | BIN | C | 07/20/2015 | | DALE | DALE | | BIN | C | 4996618 |
HOMEOWNER | BFR | C | 07/09/2015 | framing items completed, check elevator pit at final | ED | ED | | BFR | C | 4990208 |
HOMEOWNER | BFR | P | 06/23/2015 | in basement, white wood below top of slab, (( will need to remove block between studs to see if treated plate is installed)), at elevator pit add framing at where stud walll above not supported, upper floor 15" glue lam not in line with posts below as per plan - need engineering, missing nails at truss hanger B3 truss,, add stud under rim supporting floor , need manufactures instructions for wood burning fire place. | ED | ED | | BFR | P | 4979220 |
HOMEOWNER | BSP | P | 03/17/2015 | deck pier for rear deck okay | BOBF | BOBF | | BSP | P | 4918724 |
HOMEOWNER | BSP | P | 03/10/2015 | ok to cover porch lid framing -- need inspections for steel angles and thru bolts as per details on sheet S-5--( post and glue lam connections not completed) | ED | ED | | BSP | P | 4914204 |
HOMEOWNER | BSP | P | 03/05/2015 | sip panels ok on exterior | DALE | DALE | | BSP | P | 4912112 |
HOMEOWNER | BSP | R | 03/03/2015 | Need I info on sip panels | DALE | DALE | | BSP | R | 4910943 |
HOMEOWNER | BSP | R | 03/02/2015 | Back deck joists 12 in oc. Need eng for sip panels | DALE | DALE | | BSP | R | 4910074 |
HOMEOWNER | BSP | P | 01/09/2015 | piers ok | ED | ED | | BSP | P | 4883238 |
HOMEOWNER | BFN | C | 01/09/2015 | engineer inspection letter for footing, foundation, soils, open hole, and design on file | ED | ED | | BFN | C | 4883234 |
HOMEOWNER | BFT | C | 01/09/2015 | | ED | ED | | BFT | C | 4883233 |
HOMEOWNER | BFD | C | 12/17/2014 | | DALE | DALE | | BFD | C | 4873765 |
HOMEOWNER | BFN | R | 12/17/2014 | need all paperwork | DALE | DALE | | BFN | R | 4873764 |
HOMEOWNER | BFT | R | 12/17/2014 | need all paperwork | DALE | DALE | | BFT | R | 4873763 |
HOMEOWNER | BFN | P | 11/25/2014 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFN | P | 4860161 |
HOMEOWNER | BFT | P | 11/25/2014 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFT | P | 4860160 |
HOMEOWNER | BE | L | 07/03/2014 | Renewed at 7/3/2014 1:36:03 PM | MINDY | MINDY | | BE | L | 4771056 |
HOMEOWNER | E= | C | 04/25/2019 | E= OK ------- | GREGM | GREGM | | E= | C | 6178305 |
HOMEOWNER | EE | C | 10/29/2018 | | MATTHEW | MATTHEW | | EE | C | 6008479 |
HOMEOWNER | E= | R | 05/08/2018 | Missing GFCI protection for low outlet in master bathroom. ---------- Cage open bulbs that are under insulation. --------- Exterior cables under porch should be covered & run to junction boxes & capped. ------ Test /reset for laundry room can't be behind or above appliance. | JOSEPH | JOSEPH | | E= | R | 5838658 |
HOMEOWNER | E= | R | 11/13/2017 | need wr outlets at all exterior, gfci boiler outlet, afci smokes, install theater room and laundry room and foyer lights, need florescent lights in basement and main level bedroom closets, gfci within 6' of laundry sink, gfci right of cooktop and both sides of oven, add outlet left of cooktop, cord and plug connect dishwasher, need spark ring in pantry, gfci protect master ex-fan and low outlet left of vanity, ground disposal box---------------- no a/c | MATTHEW | MATTHEW | | E= | R | 5683589 |
HOMEOWNER | ER | C | 06/19/2015 | | TOMC | TOMC | | ER | C | 4977422 |
HOMEOWNER | ER | R | 05/18/2015 | not ready: complete re-inspect--------partial list: spacing, stapling, ground metal boxes, pigtail grounds, small appliance circuit to feed small appliance outlets only (lights and living room on circuits), need countertop spacing corrected, bushings on emt stubs, front and back outlets, outlets for decks---------- bath circuits dedicated, 2-100 amp sub-panels ok, no cen vac, finished basement, no mcc's | MATTHEW | MATTHEW | | ER | R | 4956585 |
HIGH MOUNTAIN ELECTRIC INC. | ESL | C | 03/20/2015 | pvc in deck slab between columns ---------- uf to be installed | MATTHEW | MATTHEW | | ESL | C | 4920865 |
HIGH MOUNTAIN ELECTRIC INC. | ES | C | 03/20/2015 | Residential Underground: 200 AMP 3/W:new res----------- meter is set------- don't need pedestal sealed at this time; contractor installing service to detached garage and hasn't landed service lateral | MATTHEW | MATTHEW | | ES | C | 4920864 |
HOMEOWNER | H= | C | 11/14/2016 | Finished basement, hot water heat, no a/c, no mantel. | MICHAELS | MICHAELS | | H= | C | 5343281 |
MORNING STAR ELEVATOR, LLC. | HE= | C | 11/24/2015 | ELEVATOR COMPLETE | JOHNW | JOHNW | | HE= | C | 5085996 |
MICK HEATING & SHEET METAL CO. | HRR | C | 03/12/2015 | Rough ok. Note: Sealed comb boiler, elec domestic w/h. | MARK | MARK | | HRR | C | 4915696 |
AMERICAN PRIDE PLUMBING | HC | C | 03/12/2015 | RELEASE METER | MARK | MARK | | HC | C | 4915695 |
AMERICAN PRIDE PLUMBING | HI | C | 03/12/2015 | 10 lb test ok. Note: 1 1/2" main. Boiler, rng, f/p (Main lvl) | MARK | MARK | | HI | C | 4915694 |
AMERICAN PRIDE PLUMBING | HI | R | 03/10/2015 | CORRECTIONS NOT MADE. | LUKE | LUKE | | HI | R | 4914233 |
AMERICAN PRIDE PLUMBING | HWP | C | 03/10/2015 | MAIN LEVEL STAPLED UP OK, .60# LB TEST OK. | LUKE | LUKE | | HWP | C | 4914232 |
AMERICAN PRIDE PLUMBING | HI | R | 03/02/2015 | Gas line is undersized with meter at road. | MICHAELS | MICHAELS | | HI | R | 4910277 |
DAVIS GAS SHOP INC | HO | C | 01/29/2015 | 10# test ok on 2" line from meter. | MICHAELS | MICHAELS | | HO | C | 4893373 |
DAVIS GAS SHOP INC | HO | P | 01/16/2015 | 2" line lost test, 10# test ok on 1" line from house to shop. | MICHAELS | MICHAELS | | HO | P | 4886460 |
AMERICAN PRIDE PLUMBING | HWP | P | 01/08/2015 | 60# test ok. Basement zone ok to pour. | MICHAELS | MICHAELS | | HWP | P | 4882471 |
HOMEOWNER | P= | C | 05/22/2017 | Certificate of potable to scanning. | CRADE | CRADE | | P= | C | 5512484 |
HOMEOWNER | P= | P | 05/02/2017 | Need certificate of potable water.Rest ok. | CRADE | CRADE | | P= | P | 5493660 |
AMERICAN PRIDE PLUMBING | PTO | C | 03/10/2015 | CORRECTIONS MADE . | GABE | GABE | | PTO | C | 4914154 |
AMERICAN PRIDE PLUMBING | PTO | P | 03/02/2015 | LOST TEST ON DWV , H2O OK , NEED VALVE AT POT FILLER AND POTABLE WATER CERT BY FINAL , FINISHED BASEMENT . NO IRRIGATION | GABE | GABE | | PTO | P | 4910522 |
AMERICAN PRIDE PLUMBING | PB | C | 12/22/2014 | | TIM | TIM | | PB | C | 4876495 |