MURPHY'S CUSTOM HOMES, INC. | B= | C | 08/08/2014 | All other required Final inspections are complete. (This is a computer generated result) | DALE | DALE | | B= | C | 4793518 |
MURPHY'S CUSTOM HOMES, INC. | B= | P | 08/07/2014 | Additional Inspections Required: Plumbing Final Inspection is not Completed yet. complete P= / HD= / unfinished basement | DALE | DALE | | B= | P | 4792694 |
MURPHY'S CUSTOM HOMES, INC. | BIN | C | 04/21/2014 | | CHRISM | CHRISM | | BIN | C | 4723697 |
MURPHY'S CUSTOM HOMES, INC. | BFR | C | 04/16/2014 | | CHRISM | CHRISM | | BFR | C | 4721448 |
MURPHY'S CUSTOM HOMES, INC. | BFR | R | 04/14/2014 | anchor bolts within 12 inches of plate breaks / HTS 20's cant be bent under top plates / roll block truss heels over 8" TO1 and TO1B / 6-8 headroom needed at stairs have 6-3-1/2 / remove float blocks / carry down point loads to foundation / need BFN cleared out | JOHN | JOHN | | BFR | R | 4719927 |
MURPHY'S CUSTOM HOMES, INC. | BSP | P | 03/27/2014 | deck piers ok, front porch ok | CHRISM | CHRISM | | BSP | P | 4710366 |
MURPHY'S CUSTOM HOMES, INC. | BSP | R | 03/24/2014 | deck piers, clean loose dirt | CHRISM | CHRISM | | BSP | R | 4707602 |
MURPHY'S CUSTOM HOMES, INC. | BFI | C | 02/12/2014 | R-10 at walkout walls ok | CHRISM | CHRISM | | BFI | C | 4685895 |
MURPHY'S CUSTOM HOMES, INC. | BFD | C | 02/12/2014 | soils and open hole on file drain usable isolate and float | CHRISM | CHRISM | | BFD | C | 4685885 |
MURPHY'S CUSTOM HOMES, INC. | BFN | R | 02/12/2014 | need eng inspection report and foundation design | CHRISM | CHRISM | | BFN | R | 4685884 |
MURPHY'S CUSTOM HOMES, INC. | BFT | C | 02/12/2014 | eng report on file | CHRISM | CHRISM | | BFT | C | 4685880 |
MURPHY'S CUSTOM HOMES, INC. | BFN | P | 02/11/2014 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFN | P | 4685500 |
MURPHY'S CUSTOM HOMES, INC. | BFT | P | 02/11/2014 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFT | P | 4685499 |
FOUNTAIN VALLEY ELECTRICAL, LLC | E= | C | 07/18/2014 | corrections made | TOMC | TOMC | | E= | C | 4779794 |
FOUNTAIN VALLEY ELECTRICAL, LLC | E= | R | 07/09/2014 | need to add counter top receptacle next to appl garage ( check inside of appl garage for receptacle ) | TOMC | TOMC | | E= | R | 4773840 |
FOUNTAIN VALLEY ELECTRICAL, LLC | E= | L | 07/08/2014 | locked 1:47------- no lock box | MATTHEW | MATTHEW | | E= | L | 4772669 |
FOUNTAIN VALLEY ELECTRICAL, LLC | E= | L | 07/07/2014 | locked 2:17 | MATTHEW | MATTHEW | | E= | L | 4771957 |
FOUNTAIN VALLEY ELECTRICAL, LLC | ES | C | 04/22/2014 | Residential Overhead: 150 amp 3/w: new res---- meter is set; need seal--------------------------- ufer needs to be exposed for final | MATTHEW | MATTHEW | | ES | C | 4724908 |
FOUNTAIN VALLEY ELECTRICAL, LLC | EUG | C | 04/21/2014 | 4/0 al service lateral from pole to house | MATTHEW | MATTHEW | | EUG | C | 4723789 |
FOUNTAIN VALLEY ELECTRICAL, LLC | ES | R | 04/21/2014 | need #4 grounding electrode conductor | MATTHEW | MATTHEW | | ES | R | 4723766 |
FOUNTAIN VALLEY ELECTRICAL, LLC | ER | C | 04/07/2014 | unfinished basement, 1-20, #6al | MATTHEW | MATTHEW | | ER | C | 4715663 |
BRUNO'S HEATING & COOLING | H= | C | 07/24/2014 | Correction made. | JEFFL | JEFFL | | H= | C | 4783451 |
BRUNO'S HEATING & COOLING | H= | P | 07/23/2014 | Need to complete vent termination. rest ok. Note: House is located on Wolford, but has a Shoup address. Unfin bsmnt, Has OSA, no a/c. | MARK | MARK | | H= | P | 4782048 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | HC | C | 04/10/2014 | RELEASE METER | JEFFL | JEFFL | | HC | C | 4742660 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | HI | C | 04/10/2014 | 10 LB test ok. Notes-- 1'' main.. 1 furnace.. 1 wh.. 1 fp.. 1 dryer. | JEFFL | JEFFL | | HI | C | 4718059 |
BRUNO'S HEATING & COOLING | HRR | C | 04/08/2014 | Rough and D/D ok. UB Direct vent furn. | MARK | MARK | | HRR | C | 4716641 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | P= | C | 08/08/2014 | | TIM | TIM | | P= | C | 4793517 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | P= | P | 08/07/2014 | dishwasher stand pipe needs to be 18" min, main bath toilet lacks 15" to side cabinet run drain off r-p to floor | TIM | TIM | | P= | P | 4792307 |
HOMEOWNER | PWO | C | 06/09/2014 | NOTE : POTABLE WATER CERT AND BACK FLOW BY FINAL | GABE | GABE | | PWO | C | 4753799 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PTO | C | 04/10/2014 | CHECK TRAP IN BASEMENT AT FINAL | GABE | GABE | | PTO | C | 4717909 |