SADDLETREE INC. | B= | C | 07/16/2014 | finished basement, deck in | DALE | DALE | | B= | C | 4778029 |
SADDLETREE INC. | B= | R | 07/15/2014 | Additional Inspections Required: External Agency Inspection HD= by HEALTHDEPT is not Completed yet. need handrail at front stairs and entry stairs / need insulation at mech. room / insulation inspection report on file / finished basement, deck in | DALE | DALE | | B= | R | 4777031 |
SADDLETREE INC. | BLA | C | 05/13/2014 | | CHRISM | CHRISM | | BLA | C | 4737664 |
SADDLETREE INC. | BFR | C | 04/29/2014 | | CHRISM | CHRISM | | BFR | C | 4729057 |
SADDLETREE INC. | BIN | P | 04/29/2014 | Qualified third party energy inspection documentation must be presented at time of final building (B=) inspection | INTERNET | INTERNET | | BIN | P | 4728752 |
SADDLETREE INC. | BSP | R | 04/07/2014 | porch roof, missing lateral braces, strongback west gable | CHRISM | CHRISM | | BSP | R | 4715538 |
SADDLETREE INC. | BSP | R | 04/03/2014 | no plans on site | CHRISM | CHRISM | | BSP | R | 4714161 |
SADDLETREE INC. | BSP | R | 03/18/2014 | should have been called as a PWO inspection
| CHRISM | CHRISM | | BSP | R | 4704272 |
SADDLETREE INC. | BFD | C | 02/11/2014 | soils and open hole on file | CHRISM | CHRISM | | BFD | C | 4685551 |
SADDLETREE INC. | BFN | C | 02/11/2014 | foundation design on file | CHRISM | CHRISM | | BFN | C | 4685545 |
SADDLETREE INC. | BFI | C | 02/10/2014 | R-10 at walkout | CHRISM | CHRISM | | BFI | C | 4684766 |
SADDLETREE INC. | BFD | P | 02/10/2014 | drain usable ok, need stamped soils and open hole | CHRISM | CHRISM | | BFD | P | 4684765 |
SADDLETREE INC. | BFN | P | 02/10/2014 | eng report on file, need foundation design for file | CHRISM | CHRISM | | BFN | P | 4684764 |
SADDLETREE INC. | BFT | C | 02/10/2014 | eng report on file | CHRISM | CHRISM | | BFT | C | 4684763 |
SADDLETREE INC. | BFN | P | 01/15/2014 | AUTHORIZED INSPECTION BY ENGINEER | NELIDA | NELIDA | NELIDA | BFN | P | 4672271 |
SADDLETREE INC. | BFT | P | 01/15/2014 | AUTHORIZED INSPECTION BY ENGINEER | NELIDA | NELIDA | NELIDA | BFT | P | 4672270 |
D & J QUALITY ELECTRIC INC | E= | C | 07/14/2014 | 40 amp a/c ok | MATTHEW | MATTHEW | | E= | C | 4776397 |
D & J QUALITY ELECTRIC INC | E= | L | 07/11/2014 | Complete re-inspection required. Sign says wet floors stay off until Saturday------------- Exterior front door outlet is loose and has broken cover plate | JOSEPH | JOSEPH | | E= | L | 4775699 |
D & J QUALITY ELECTRIC INC | EUG | C | 05/16/2014 | service lateral from pole to home | MATTHEW | MATTHEW | | EUG | C | 4740540 |
D & J QUALITY ELECTRIC INC | ES | C | 05/16/2014 | Residential Overhead: 200 amp 3/w: new res----- meter is set; need seal | MATTHEW | MATTHEW | | ES | C | 4740536 |
D & J QUALITY ELECTRIC INC | ER | C | 04/28/2014 | finished basement, check spacing in room off garage at final | MATTHEW | MATTHEW | | ER | C | 4728330 |
D & J QUALITY ELECTRIC INC | ER | R | 04/23/2014 | wire fireplaces, per contractor bookcase will be installed in room off garage; check spacing at final--------finished basement | MATTHEW | MATTHEW | | ER | R | 4725804 |
OLYMPIA HEATING & COOLING INC. | H= | C | 07/10/2014 | correction made | TED | TED | | H= | C | 4774429 |
OLYMPIA HEATING & COOLING INC. | H= | P | 07/07/2014 | Missing T&P drain pipe, need clearance between insulation and w/h b vent. Rest ok. Note: Fin Bsmnt, has a/c and louver door to mech with transfer grill for laundry. | MARK | MARK | | H= | P | 4771643 |
OLYMPIA HEATING & COOLING INC. | HC | C | 04/18/2014 | RELEASE METER | JEFFL | JEFFL | | HC | C | 4723365 |
OLYMPIA HEATING & COOLING INC. | HRR | C | 04/18/2014 | Corrections made. | JEFFL | JEFFL | | HRR | C | 4723364 |
KAMPP-L ENTERPRISES, INC. | HI | C | 04/14/2014 | 10 LB.pressure test ok. Notes-- 1 1/4'' main.. 1 furnace.. 1 water heater. | JEFFL | JEFFL | | HI | C | 4719896 |
OLYMPIA HEATING & COOLING INC. | HRR | P | 04/11/2014 | Framing not complete around b vent and duct work. Bath exhaust vents not connected to exhaust fans. Rest ok. Notes-- AC rough.. finished basement..OSA to return.. | JEFFL | JEFFL | | HRR | P | 4719124 |
KAMPP-L ENTERPRISES, INC. | P= | C | 07/08/2014 | NOTE : FINISHED BASEMENT . RP INSTALLED FOR WATER TO BARN . NO IRRIGATION . POTABLE WATER CERT TO SCANNING | GABE | GABE | | P= | C | 4772482 |
KAMPP-L ENTERPRISES, INC. | PWO | C | 06/19/2014 | WATER LINE OUT TO POLE BARN . BACK FLOW REQUIRED BY FINAL | GABE | GABE | | PWO | C | 4761200 |
KAMPP-L ENTERPRISES, INC. | PTO | C | 04/11/2014 | WATER TEST OK . CORRECTIONS MADE | GABE | GABE | | PTO | C | 4718695 |
KAMPP-L ENTERPRISES, INC. | PTO | P | 04/10/2014 | DWV OK , IMPROPER TEST ON WATER, GAUGE STUCK AT 100, CALL TO EXPLAIN | GABE | GABE | | PTO | P | 4717830 |
SADDLETREE INC. | PWO | P | 03/19/2014 | 6-17-14 JB...CHANGED STATUS TO ENABLE YARD LINE INSPECTION TO BARN, HOUSE LINE OK ALREADY INSPECTED. | TIM | TIM | | PWO | P | 4704827 |
KAMPP-L ENTERPRISES, INC. | PB | C | 03/05/2014 | | TIM | TIM | | PB | C | 4697152 |