HOMEOWNER | B= | C | 08/29/2022 | All other required Final inspections are complete. (This is a computer generated result) | DALE | DALE | | B= | C | 7498835 |
HOMEOWNER | BE | L | 08/10/2022 | Renewed for No Fee at 8/10/2022 2:39:38 PM | JACKIEP | JACKIEP | | BE | L | 7478403 |
HOMEOWNER | B= | P | 05/01/2015 | complete all other inspections. Additional Inspections Required (computer generated): Mechanical Final Inspection is not Completed yet, Plumbing Final Inspection is not Completed yet. | DALE | DALE | | B= | P | 4947516 |
HOMEOWNER | BE | C | 04/20/2015 | | RITA | RITA | | BE | C | 4938719 |
HOMEOWNER | B= | R | 09/26/2014 | Additional Inspections Required: Electrical Final Inspection is not Completed yet, Mechanical Final Inspection is not Completed yet, Plumbing Final Inspection is not Completed yet. need 5" address# on house / need stairs at front and back doors / need c/o detector? / complete all other inspections | DALE | DALE | | B= | R | 4823627 |
HOMEOWNER | BIN | P | 06/10/2014 | changed from lath to insulation inspection i assume thats what it should have been, insulation thats not covered is ok, should have been inspected prior to hanging sheetrock | CHRISM | CHRISM | | BIN | P | 4754816 |
SADDLETREE INC. | BFR | C | 05/06/2014 | | CHRISM | CHRISM | | BFR | C | 4733532 |
SADDLETREE INC. | BLA | C | 05/05/2014 | | ED | ED | | BLA | C | 4733048 |
SADDLETREE INC. | BFR | R | 05/02/2014 | ok to insulate, steel shim beam pockets | CHRISM | CHRISM | | BFR | R | 4731736 |
SADDLETREE INC. | BIN | P | 04/29/2014 | Qualified third party energy inspection documentation must be presented at time of final building (B=) inspection | INTERNET | INTERNET | | BIN | P | 4729678 |
SADDLETREE INC. | BLA | R | 04/28/2014 | not ready | CHRISM | CHRISM | | BLA | R | 4728045 |
SADDLETREE INC. | BFN | C | 02/19/2014 | foundation design on file | CHRISM | CHRISM | | BFN | C | 4689525 |
SADDLETREE INC. | BFI | R | 02/14/2014 | not installed | CHRISM | CHRISM | | BFI | R | 4687552 |
SADDLETREE INC. | BFD | C | 02/14/2014 | soils and open hole on file drain usable isolate and float | CHRISM | CHRISM | | BFD | C | 4687551 |
SADDLETREE INC. | BFN | P | 02/14/2014 | eng report on file need clean - complete copy of foundation design | CHRISM | CHRISM | | BFN | P | 4687549 |
SADDLETREE INC. | BFT | C | 02/14/2014 | eng report on file | CHRISM | CHRISM | | BFT | C | 4687543 |
HOMEOWNER | E= | C | 10/24/2014 | | MATTHEW | MATTHEW | | E= | C | 4841904 |
HOMEOWNER | E= | R | 10/13/2014 | afci dining room lights and outlets, expose ufer, need handle ties on multi-conductor circuits and they need to be on different phases, install ge breakers, neutrals landed on ground bar, in-use covers upside down and all exterior need to be weather resistant, 15 amp breaker labeled kitchen outlets?--------------------- a/c pre-wire------------------- | MATTHEW | MATTHEW | | E= | R | 4833512 |
HOMEOWNER | E= | R | 09/26/2014 | need to meet electrician on site: complete re-inspect, in-use covers installed backwards, missing exterior outlet, neutral landed on ground bar at a/c, install inter-system bond terminal, need 2 small appliance circuits, no power to exterior light and kitchen outlets, panel not labeled afci breakers not installed, all outlets need to be tamper resistant, need material removed from walls | MATTHEW | MATTHEW | | E= | R | 4824012 |
HOMEOWNER | E= | R | 07/14/2014 | ---------------------------------------------------Homeowner taking over, First Rate electric only responsible for the rough and service. Final electrical to be called by owner or another electrical contractor------------------------------------------- | DEAN | DEAN | | E= | R | 4776508 |
FIRST RATE ELECTRICAL SERVICES, INC. | ES | C | 05/01/2014 | Residential Overhead: 200 amp 3/w: meter set and sealed by MTVE | MATTHEW | MATTHEW | | ES | C | 4731153 |
FIRST RATE ELECTRICAL SERVICES, INC. | ES | R | 04/30/2014 | 200 amp 3/w service and sub-panel ok------- need meter repaired before i can pass service | MATTHEW | MATTHEW | | ES | R | 4730203 |
FIRST RATE ELECTRICAL SERVICES, INC. | ER | C | 04/30/2014 | 1-20, #6al---crawler | MATTHEW | MATTHEW | | ER | C | 4730202 |
FIRST RATE ELECTRICAL SERVICES, INC. | ES | R | 04/29/2014 | unable to reach service disconnect; need ladder, lug on load side of meter has broken off and service conductor in laying against can | MATTHEW | MATTHEW | | ES | R | 4729235 |
FIRST RATE ELECTRICAL SERVICES, INC. | ER | R | 04/29/2014 | 4/0 al in insulation needs to be derated to 150 amps, install running boards at attic access, 1-20, #6al | MATTHEW | MATTHEW | | ER | R | 4729212 |
FIRST RATE ELECTRICAL SERVICES, INC. | EUG | C | 04/29/2014 | service lateral from pole to home | MATTHEW | MATTHEW | | EUG | C | 4729211 |
HOMEOWNER | H= | C | 05/01/2015 | correction made | TED | TED | | H= | C | 4947702 |
HOMEOWNER | H= | R | 09/26/2014 | need 1'' clearance around b vent from dry wall at ceiling, need to complete furnace work in crawlspace, note: no a/c, conditioned crawlspace | TED | TED | | H= | R | 4823861 |
O.M.A.G.M., INC. | HO | C | 06/10/2014 | 10 lb test ok. 100' of 1 1/4" PE pipe from meter to house. | MARK | MARK | | HO | C | 4754558 |
OLYMPIA HEATING & COOLING INC. | HC | C | 05/01/2014 | RELEASE METER | JERRYF | JERRYF | | HC | C | 4730803 |
OLYMPIA HEATING & COOLING INC. | HRR | C | 05/01/2014 | ALL CORRECTIONS MADE | JERRYF | JERRYF | | HRR | C | 4730798 |
OLYMPIA HEATING & COOLING INC. | HRR | P | 04/30/2014 | SEAL WIRING IN RETURN STUB BAY AT MASTER BATHROOM - NEED NAIL PROTECTION ON FURNACE INTAKE AT CEILING - REST OK. NOTES: DIRECT VENT FURNACE IN CRAWLSPACE - 6" OSA TO FURNACE - AC ROUGH - IF FULL AC AT FINAL CONFIRM CONDENSATE DRAINS | JERRYF | JERRYF | | HRR | P | 4730511 |
OLYMPIA HEATING & COOLING INC. | HRR | L | 04/29/2014 | NEED APPROVED DUCT DESIGN - NEED LADDER FOR ACCESS TO CRAWLSPACE - STOPPED INSPECTION - RE INSPECT ALL | JERRYF | JERRYF | | HRR | L | 4729241 |
KAMPP-L ENTERPRISES, INC. | HI | C | 04/24/2014 | 10 PSI TEST OK. NOTE: 11/4 BLK - WATER HEATER, FURNACE AND RANGE | JERRYF | JERRYF | | HI | C | 4726615 |
HOMEOWNER | P= | C | 08/29/2022 | | LEE | LEE | | P= | C | 7498834 |
HOMEOWNER | P= | L | 08/11/2022 | LOCKED STATUS FOR ADMIN-CLOSED PERMIT -- STILL NEED HIGH-LOOP AND AAV AT KITCHEN -- MASTER TUB REQUIRES PUMP ACCESS -- NEED TO FIX DEFECTIVE TUB / SHOWER VALVE ( HANDLE SPINS 180 DEGREES ) -- NEED POTABLE H20 CERT | LEE | LEE | | P= | L | 7479074 |
HOMEOWNER | P= | R | 05/01/2015 | no change from last inspection, also will check the master tub next trip, was told it is going to be removed and capped up if it not installed | TED | TED | | P= | R | 4947698 |
HOMEOWNER | P= | R | 09/26/2014 | NEED AAV AT KITCHEN , WASTE NOT CONNECTED ON RIGHT BOWL . NEED HI LOOP FROM DISH WASHER , BOTH SHOWER VALVES REVERSED . TUB IN MASTER NEEDS TO BE SET AND TESTED . POTABLE WATER CERT REQUIRED FOR FINAL . | GABE | GABE | | P= | R | 4823531 |
HOMEOWNER | PWO | C | 08/11/2014 | need certificate of potable water by final | TED | TED | | PWO | C | 4794241 |
HOMEOWNER | PWO | P | 06/10/2014 | NEED TO SEE CONNECTION BEFORE BACKFILL | GABE | GABE | | PWO | P | 4754554 |
KAMPP-L ENTERPRISES, INC. | PTO | C | 04/23/2014 | POTABLE WATER CERTIFICATE BY FINAL | GABE | GABE | | PTO | C | 4725551 |
KAMPP-L ENTERPRISES, INC. | PB | C | 03/04/2014 | | DICK | DICK | | PB | C | 4696352 |