MAJESTIC CUSTOM HOMES, INC. | B= | C | 07/24/2014 | All other required Final inspections are complete. (This is a computer generated result) | JEREMYC | JEREMYC | | B= | C | 4783711 |
MAJESTIC CUSTOM HOMES, INC. | B= | P | 07/24/2014 | Additional Inspections Required: External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | JEREMYC | JEREMYC | | B= | P | 4783609 |
MAJESTIC CUSTOM HOMES, INC. | BIN | C | 05/27/2014 | finished basement | CHRISM | CHRISM | | BIN | C | 4745815 |
MAJESTIC CUSTOM HOMES, INC. | BFR | C | 05/22/2014 | | CHRISM | CHRISM | | BFR | C | 4744108 |
MAJESTIC CUSTOM HOMES, INC. | BLA | C | 04/25/2014 | | CHRISM | CHRISM | | BLA | C | 4727268 |
MAJESTIC CUSTOM HOMES, INC. | BSP | P | 04/08/2014 | front porch and deck columns ok | CHRISM | CHRISM | | BSP | P | 4716086 |
MAJESTIC CUSTOM HOMES, INC. | BSP | P | 03/28/2014 | deck piers ok | CHRISM | CHRISM | | BSP | P | 4710667 |
MAJESTIC CUSTOM HOMES, INC. | BFI | C | 02/18/2014 | R-10 at walkout | CHRISM | CHRISM | | BFI | C | 4688359 |
MAJESTIC CUSTOM HOMES, INC. | BFD | C | 02/18/2014 | soils on file drain usable isolate and float | CHRISM | CHRISM | | BFD | C | 4688357 |
MAJESTIC CUSTOM HOMES, INC. | BFN | C | 02/18/2014 | design and eng report on file | CHRISM | CHRISM | | BFN | C | 4688356 |
MAJESTIC CUSTOM HOMES, INC. | BFT | C | 02/18/2014 | eng report on file | CHRISM | CHRISM | | BFT | C | 4688355 |
MAJESTIC CUSTOM HOMES, INC. | BFN | P | 01/24/2014 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFN | P | 4677113 |
MAJESTIC CUSTOM HOMES, INC. | BFT | P | 01/24/2014 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFT | P | 4677112 |
PEAK ELECTRIC INC. | E= | C | 07/23/2014 | outlet for generator has been removed (future)----- 30 amp a/c | MATTHEW | MATTHEW | | E= | C | 4782665 |
PEAK ELECTRIC INC. | E= | R | 07/22/2014 | generator is not listed for tandem breakers (contractor provided paperwork; verify panel is ch816gen6060), need switched neutral for portable generator rated less than 10kva, wet bar gfci won't set (need to check gfci and afci protection at re-inspect), tape neutral butt splices at cooking disconnects (neutral up against can), tc cable ran thru unfinished area is still not installed in conduit, need afci protection for exterior lights that have switches in areas that require afci protection--------------- 30 amp a/c ok | MATTHEW | MATTHEW | | E= | R | 4781728 |
PEAK ELECTRIC INC. | E= | R | 07/16/2014 | reverse polarity laundry outlet, generator panel not listed for tandem breakers, need switched neutral for portable generator, I turned off a non-afci breaker and carpenters said it turned off master bed room lights------------- contractor needs to check house; complete re-inspect---- I checked exterior and garage only----- still need to check gfci protection for exterior outlets on south side of house | MATTHEW | MATTHEW | | E= | R | 4778287 |
PEAK ELECTRIC INC. | EUG | C | 05/16/2014 | service lateral from pedestal to home ok | MATTHEW | MATTHEW | | EUG | C | 4740485 |
PEAK ELECTRIC INC. | ES | C | 05/16/2014 | Residential Underground: 200 amp 3/w: new res--------------- meter is set; need seal | MATTHEW | MATTHEW | | ES | C | 4740484 |
PEAK ELECTRIC INC. | ER | C | 05/16/2014 | finished basement, 3-20, 1-15, 6-3nm stub-------------------------- tc cable ran thru unfinished area of basement will need to be in a conduit by final-------------------------- | MATTHEW | MATTHEW | | ER | C | 4740475 |
BRUNO'S HEATING & COOLING | H= | C | 07/24/2014 | Final ok. Note: Has a/c. OSA, fin bsmnt. Hi/Lo grills. | MARK | MARK | | H= | C | 4783166 |
BRUNO'S HEATING & COOLING | HC | C | 05/21/2014 | RELEASE METER | MARK | MARK | | HC | C | 4742736 |
BRUNO'S HEATING & COOLING | HRR | C | 05/21/2014 | Rough and duct design ok. Note: Fin bsmnt a/c rough. Direct vent furn. OSA to return | MARK | MARK | | HRR | C | 4742721 |
DOUBLE J GAS, INC. | HI | C | 05/15/2014 | 10lb test ok. Note: Furn, w/h, rng, bbq. 1 1/4" main | MARK | MARK | | HI | C | 4739876 |
PACIFIC PLUMBING, INCORPORATED | P= | C | 07/24/2014 | received potable water cert | TIM | TIM | | P= | C | 4782855 |
PACIFIC PLUMBING, INCORPORATED | P= | P | 07/21/2014 | still need proof of potable | TIM | TIM | | P= | P | 4780616 |
PACIFIC PLUMBING, INCORPORATED | P= | R | 07/17/2014 | complete tile work in all showers for testing, need certificate of potable water, note: finished basement, 3/4'' pvb installed | TED | TED | | P= | R | 4778905 |
PACIFIC PLUMBING, INCORPORATED | PTO | C | 04/04/2014 | NEED APPROVED FITTING ON PEX TO COPPER AT MAIN BY FINAL , 5 PSI TEST ON DWV , 50 ON WATER | GABE | GABE | | PTO | C | 4714603 |
PACIFIC PLUMBING, INCORPORATED | PB | C | 02/25/2014 | | DICK | DICK | | PB | C | 4692712 |