CAMPBELL HOMES LTD. | B= | C | 05/23/2014 | Finished basement | NICK | NICK | | B= | C | 4744644 |
CAMPBELL HOMES LTD. | BLA | C | 03/31/2014 | | ED | ED | | BLA | C | 4711900 |
CAMPBELL HOMES LTD. | BIN | C | 03/24/2014 | | ED | ED | | BIN | C | 4707373 |
CAMPBELL HOMES LTD. | BFR | C | 03/20/2014 | finished basement | ED | ED | | BFR | C | 4705985 |
CAMPBELL HOMES LTD. | BSP | P | 03/13/2014 | front porch frame ok | NICK | NICK | | BSP | P | 4701564 |
CAMPBELL HOMES LTD. | BFD | C | 02/19/2014 | | ED | ED | | BFD | C | 4689624 |
CAMPBELL HOMES LTD. | BFT | C | 02/18/2014 | | ED | ED | | BFT | C | 4688975 |
CAMPBELL HOMES LTD. | BFN | C | 02/18/2014 | engineer inspection letter for footing, / foundation, / foundation design, / and soils report on file | ED | ED | | BFN | C | 4688970 |
CAMPBELL HOMES LTD. | BFD | R | 02/18/2014 | filer fabric missing over drain rock | ED | ED | | BFD | R | 4688966 |
CAMPBELL HOMES LTD. | BFN | P | 01/30/2014 | AUTHORIZED INSPECTION BY ENGINEER | BPHILLIPS | BPHILLIPS | BPHILLIPS | BFN | P | 4680320 |
CAMPBELL HOMES LTD. | BFT | P | 01/30/2014 | AUTHORIZED INSPECTION BY ENGINEER | BPHILLIPS | BPHILLIPS | BPHILLIPS | BFT | P | 4680319 |
POSITIVE ELECTRIC, LLC | E= | C | 05/16/2014 | NOTES---AC. PRE WIRE-----WET BAR ROUGH IN BASEMENT----- | BRIAN | BRIAN | | E= | C | 4740707 |
POSITIVE ELECTRIC, LLC | ES | C | 03/19/2014 | Residential Underground: 150 amp 3w new res meter in need to reseal | JOSEPH | JOSEPH | | ES | C | 4705078 |
POSITIVE ELECTRIC, LLC | ER | C | 03/19/2014 | Finished basement-------------- 3 - 6/3 al 2 - 20 | JOSEPH | JOSEPH | | ER | C | 4705076 |
POSITIVE ELECTRIC, LLC | EUG | C | 02/25/2014 | 2/0 urd ok | TOMC | TOMC | | EUG | C | 4693059 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 05/20/2014 | finished basement, no a/c, performance test to scanning | TED | TED | | H= | C | 4742519 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HC | C | 03/20/2014 | RELEASE METER | MARK | MARK | | HC | C | 4705552 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 03/20/2014 | Plans not to design of mechanical system. Will have a performance test by final. Returns in question on plans have been changed to transfer grills per Campbell homes and will be removed from future plans. Ok. | MARK | MARK | | HRR | C | 4705551 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | R | 03/19/2014 | Plans call for a bedroom (#2) on main level. Bedroom is missing? Plans show a return in b/r#2 and a return in study. Neither of which are present. Also missing is one of the two heat runs in the master bedroom. Plans call for a 6" heat run in b/r #2. 5" was run instead. So, plans do not match duct design as stated in original HRR. Need to insulate bath fans all the way to the box.
| MARK | MARK | | HRR | R | 4704868 |
DOUBLE J GAS, INC. | HI | C | 03/18/2014 | 10lb test ok. Note: 1 1/4" main. F, w/h, f/p, ct. | MARK | MARK | | HI | C | 4704315 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | R | 03/18/2014 | Not ready. Venting not completed for furnace at time of inspection. Plans do not match duct design. | MARK | MARK | | HRR | R | 4704314 |
SPRINGS CUSTOM PLUMBING, INC. | P= | C | 05/19/2014 | pvb installed | TIM | TIM | | P= | C | 4741650 |
SPRINGS CUSTOM PLUMBING, INC. | PTO | C | 03/18/2014 | | TIM | TIM | | PTO | C | 4704683 |
SPRINGS CUSTOM PLUMBING, INC. | PB | C | 02/24/2014 | | TIM | TIM | | PB | C | 4692131 |