BUILTRITE BUILDERS | B= | C | 09/08/2014 | All other required Final inspections are complete. (This is a computer generated result) | BOBF | BOBF | | B= | C | 4811628 |
BUILTRITE BUILDERS | B= | P | 09/04/2014 | Additional Inspections Required: External Agency Inspection HD= by HEALTHDEPT is not Completed yet, Electrical Final Inspection is not Completed yet. building okay / pending Elec and health | BOBF | BOBF | | B= | P | 4809614 |
BUILTRITE BUILDERS | BLA | C | 07/21/2014 | | DALE | DALE | | BLA | C | 4780459 |
BUILTRITE BUILDERS | BIN | C | 07/01/2014 | | JOHN | JOHN | | BIN | C | 4769045 |
BUILTRITE BUILDERS | BFR | C | 06/27/2014 | | CHRISM | CHRISM | | BFR | C | 4766927 |
BUILTRITE BUILDERS | BFR | R | 06/25/2014 | ok to insulate, anchor bolt garage plate breaks, missing H2.5 garage south wall, wrong hangers installed to support CG1 girder | CHRISM | CHRISM | | BFR | R | 4765420 |
BUILTRITE BUILDERS | BSP | P | 04/29/2014 | front and rear porch roofs and posts ok | CHRISM | CHRISM | | BSP | P | 4729331 |
BUILTRITE BUILDERS | BFI | C | 02/28/2014 | R-10 at walkout walls | CHRISM | CHRISM | | BFI | C | 4694928 |
BUILTRITE BUILDERS | BFD | C | 02/28/2014 | soils on file drain usable isolate and float | CHRISM | CHRISM | | BFD | C | 4694921 |
BUILTRITE BUILDERS | BFN | C | 02/28/2014 | design and eng report on file | CHRISM | CHRISM | | BFN | C | 4694920 |
BUILTRITE BUILDERS | BFT | C | 02/28/2014 | eng report on file | CHRISM | CHRISM | | BFT | C | 4694917 |
POSITIVE ELECTRIC, LLC | E= | C | 09/08/2014 | | MATTHEW | MATTHEW | | E= | C | 4811627 |
POSITIVE ELECTRIC, LLC | E= | P | 09/03/2014 | need to afci bath circuit; sink in bedroom-------------- 40 amp a/c and hot tub pre-wire | MATTHEW | MATTHEW | | E= | P | 4809070 |
POSITIVE ELECTRIC, LLC | ES | C | 06/04/2014 | Residential Overhead: 200 amp 3/w: new res: meter is set; need seal | MATTHEW | MATTHEW | | ES | C | 4751337 |
POSITIVE ELECTRIC, LLC | ER | C | 05/29/2014 | 2 - 20 3 - 10/3 3 - 6/3 al 6/3 cu to hot tub finished basement | CRAIG | CRAIG | | ER | C | 4747916 |
POSITIVE ELECTRIC, LLC | EUG | C | 03/25/2014 | service lateral from pole to home | MATTHEW | MATTHEW | | EUG | C | 4708367 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 08/26/2014 | All repairs completed. Ok. | MARK | MARK | | H= | C | 4803824 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | T | 08/19/2014 | PAID (REC#1215902): Intake still blocked with mortar. See previous heat final notes. Still need T&P drain pipes installed. Rest ok. | MARK | MARK | | H= | T | 4799504 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | P | 08/12/2014 | Need min 12x12 grills for hi/lo combustion air to mech rm. Metal grills have a reduction factor of 25%. Need to clear mortar from furnace vent intake. F/P mantle lacks clearance per mfg. See page 53. (Main lvl) Need T&P drain pipes on both water heaters. | MARK | MARK | | H= | P | 4795105 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | R | 06/23/2014 | I can't final without drywall up. Not able to see combustion air heat runs and returns could get covered with rock. B vent jack and cap aren't on yet, Looks like a rough inspection. Call me if you have questions. | MARK | MARK | | H= | R | 4763115 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HC | C | 06/03/2014 | RELEASE METER | MARK | MARK | | HC | C | 4750147 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 06/03/2014 | Straps added. | MARK | MARK | | HRR | C | 4750142 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | P | 05/30/2014 | Need to secure dryer vent to structure. Rest ok. Fin Bsmnt, a/c rough. direct vent furnace and 2 w/h. | MARK | MARK | | HRR | P | 4748399 |
RIDGEVIEW PLUMBING | HI | C | 05/20/2014 | 10 lb test ok. Note: 1 1/2" main.(1) F, (2) w/h. (2) f/p, rng. Future garage heater. | MARK | MARK | | HI | C | 4741906 |
RIDGEVIEW PLUMBING | P= | C | 08/27/2014 | POTABLE WATER CERT SCANNING . NOTE . FINISHED BASEMENT . NO IRRIGATION | GABE | GABE | | P= | C | 4805108 |
RIDGEVIEW PLUMBING | PWO | C | 06/03/2014 | PTFE SLEEVED THROUGH FOUNDATION . BACK FLOW REQUIRED FOR HYDRANT ON SECOND LINE OUT BY FINAL | GABE | GABE | | PWO | C | 4750193 |
RIDGEVIEW PLUMBING | PTO | C | 05/20/2014 | NOTE :FINISHED BASEMENT , IRRIGATION STUB . POTABLE WATER CERTIFICATE BY FINAL | GABE | GABE | | PTO | C | 4741968 |
RIDGEVIEW PLUMBING | PB | C | 03/06/2014 | | DICK | DICK | | PB | C | 4697928 |