HOMEOWNER | B= | C | 10/31/2014 | | BOBF | BOBF | | B= | C | 4846105 |
HOMEOWNER | B= | R | 10/28/2014 | Additional Inspections Required: Plumbing Final Inspection is not Completed yet. need smoke detector at 1st floor hallway / need address # on house / complete all other inspections | DALE | DALE | | B= | R | 4843137 |
HOMEOWNER | BSP | P | 09/26/2014 | went over fireplace with home owner | DALE | DALE | | BSP | P | 4823591 |
HOMEOWNER | BLA | C | 07/17/2014 | | DALE | DALE | | BLA | C | 4778924 |
HOMEOWNER | BLA | R | 07/17/2014 | not ready for lath inspection | DALE | DALE | | BLA | R | 4778562 |
HOMEOWNER | BSP | R | 07/03/2014 | wrong inspection needs ER | CHRISM | CHRISM | | BSP | R | 4770716 |
HOMEOWNER | BSP | P | 06/30/2014 | roof trusses ok, ok to foam deck after other roughs | CHRISM | CHRISM | | BSP | P | 4767912 |
HOMEOWNER | BSP | P | 06/24/2014 | went over roof framing with homeowner | CHRISM | CHRISM | | BSP | P | 4764669 |
HOMEOWNER | BIN | P | 06/16/2014 | Qualified third party energy inspection documentation must be presented at time of final building (B=) inspection | INTERNET | INTERNET | | BIN | P | 4758927 |
HOMEOWNER | BSP | P | 04/24/2014 | second floor ICF walls ok | CHRISM | CHRISM | | BSP | P | 4726746 |
HOMEOWNER | BSP | P | 04/17/2014 | second floor ok, need AWS cert | CHRISM | CHRISM | | BSP | P | 4722313 |
HOMEOWNER | BSP | P | 04/02/2014 | main floor walls ok, retaining wall footer ok | CHRISM | CHRISM | | BSP | P | 4713265 |
HOMEOWNER | BSP | P | 03/25/2014 | main level bar joists and volcraft decking ok, underslab insulation ok | CHRISM | CHRISM | | BSP | P | 4707959 |
HOMEOWNER | BSP | P | 03/12/2014 | main level walls on garage area ok | CHRISM | CHRISM | | BSP | P | 4701044 |
HOMEOWNER | BFN | P | 03/07/2014 | garage and upper level walls ok | CHRISM | CHRISM | | BFN | P | 4698986 |
HOMEOWNER | BFN | P | 02/27/2014 | garage walls ok | CHRISM | CHRISM | | BFN | P | 4694371 |
HOMEOWNER | BFT | C | 02/21/2014 | upper footer ok | CHRISM | CHRISM | | BFT | C | 4690953 |
HOMEOWNER | BFT | P | 02/19/2014 | 2000# bearing, lower footer and pads ok | CHRISM | CHRISM | | BFT | P | 4689290 |
HOMEOWNER | E= | C | 10/27/2014 | no a/c | MATTHEW | MATTHEW | | E= | C | 4842483 |
HOMEOWNER | E= | P | 10/24/2014 | homeowner and mat have list------- mat must do inspection | MATTHEW | MATTHEW | | E= | P | 4841991 |
HOMEOWNER | E= | R | 10/23/2014 | homeowner and mat have list------- mat must do re-inspect | MATTHEW | MATTHEW | | E= | R | 4840709 |
HOMEOWNER | ES | C | 10/23/2014 | Residential Underground: 400 amp 3/w----- meter is set and sealed | MATTHEW | MATTHEW | | ES | C | 4840583 |
HOMEOWNER | E= | R | 10/06/2014 | complete re-inspect-----------inspected front exterior and upstairs only------- partial list: gfci washer, ground switches and lights in afton bathroom, missing front exterior and upper deck outlets, exterior outlets need to be weather rated, need in-use covers for exterior outlets, uf for post lights need to land in box or poles installed, no power to loft outlets, install stair light, label panels correctly, label switches, need access and disconnect for steamer--------------- complete re-inspect | MATTHEW | MATTHEW | | E= | R | 4829032 |
HOMEOWNER | ES | R | 10/06/2014 | install inter-system bond terminal, expose ufer, land ground bar, separate neutrals and grounds in sub-panel----------- complete re-inspect-------- i didn't check meter | MATTHEW | MATTHEW | | ES | R | 4829025 |
HOMEOWNER | ER | C | 07/16/2014 | panels not made up at this time; check at time of service inspection | MATTHEW | MATTHEW | | ER | C | 4778181 |
HOMEOWNER | ER | R | 07/11/2014 | Not ready complete re-inspection required-----------Gave consultation | JOSEPH | JOSEPH | | ER | R | 4775685 |
HOMEOWNER | ER | P | 07/08/2014 | upper floor ok---- main level exterior framed walls (2 sections) ok | MATTHEW | MATTHEW | | ER | P | 4772641 |
HOMEOWNER | ER | P | 07/03/2014 | exterior walls upper floor ok to cover | MATTHEW | MATTHEW | | ER | P | 4771261 |
HOMEOWNER | EUG | C | 04/02/2014 | service lateral from pedestal to home | MATTHEW | MATTHEW | | EUG | C | 4713269 |
HOMEOWNER | ESL | C | 03/25/2014 | non metallic seal tite for floor boxes thru out house----------- boxes not installed at this time | MATTHEW | MATTHEW | | ESL | C | 4708349 |
ABC PLUMBING AND HEATING LLC | H= | C | 09/05/2014 | Final ok. Note: No door at master toilet. Direct vent boiler. No a/c. | MARK | MARK | | H= | C | 4810494 |
HOMEOWNER | HC | C | 07/18/2014 | RELEASE METER | MARK | MARK | | HC | C | 4779397 |
HOMEOWNER | HRR | C | 07/18/2014 | Rough ok.
| MARK | MARK | | HRR | C | 4779393 |
ABC PLUMBING AND HEATING LLC | HV | P | 07/11/2014 | Need MFG installation instructions for this product. Need clearance to combustibles per mfg. Note:30' of vertical concentric vent pipe (Centrotherm) 3" inner 5" steel outter. Installed with zero clearance. | MARK | MARK | | HV | P | 4775066 |
HOMEOWNER | HRR | P | 07/08/2014 | Not ready as F/P vents are not installed, f/p's are not secured to framing. Bath fans are ok, lower level dryer vent is ok, upper level dryer vent is not connected. | MARK | MARK | | HRR | P | 4772359 |
ABC PLUMBING & ELEC. SUPPLY | HI | P | 06/13/2014 | 10 lb test ok. F/P's are not ordered yet. Ok to cover, will complete when ready. | MARK | MARK | | HI | P | 4757442 |
ABC PLUMBING & ELEC. SUPPLY | HI | R | 06/04/2014 | all csst lines are under sized, must size csst from the regulator, need total btu load and fixture count for the house, if there are fireplaces to be installed they need to be installed and gas piping run into the cabinet, also need to be sure the csst run through slab in sized for btu load for this outlet | TED | TED | | HI | R | 4751149 |
HOMEOWNER | HWP | C | 04/17/2014 | ok to cover 2nd floor | TED | TED | | HWP | C | 4722112 |
HOMEOWNER | HWP | P | 03/26/2014 | ok to cover 1st floor | TED | TED | | HWP | P | 4709524 |
HOMEOWNER | HWP | L | 03/25/2014 | Field cancelled. | JEFFL | JEFFL | | HWP | L | 4708232 |
AMERICAN PRIDE PLUMBING | HI | P | 03/20/2014 | 2-3/4" csst in sleeves under slab. 10# test ok. | MICHAELS | MICHAELS | | HI | P | 4705954 |
HOMEOWNER | P= | C | 10/30/2014 | received potable water cert | TIM | TIM | | P= | C | 4845028 |
HOMEOWNER | P= | P | 10/27/2014 | need proof of potable water | TIM | TIM | | P= | P | 4842503 |
HOMEOWNER | P= | R | 10/20/2014 | waive trip fee not ready to many items plumb dbl lavs to code only 1 slip joint allowed down stream of trap, cut cap off vent, valves for wall faucet, pump access, need access to all bathrooms, set water temps at tub and showers....stopped inspection | TIM | TIM | | P= | R | 4837910 |
HOMEOWNER | PTO | C | 07/11/2014 | AAV AT LAV UNDER STAIRS . AND AT KITCHEN X2 . POTABLE WATER CERT . BY FINAL | GABE | GABE | | PTO | C | 4775055 |
HOMEOWNER | PWO | C | 04/23/2014 | POTABLE WATER CERTIFICATE BY FINAL | GABE | GABE | | PWO | C | 4725492 |
HOMEOWNER | PB | C | 03/21/2014 | | TIM | TIM | | PB | C | 4706511 |
HOMEOWNER | PB | P | 03/06/2014 | garage dwv only. need upper level. | DICK | DICK | | PB | P | 4697909 |
HOMEOWNER | PWO | R | 03/05/2014 | ditch not even dug yet...trip fee??? | TIM | TIM | | PWO | R | 4697080 |