RAMPART CONSTRUCTION | B= | C | 09/01/2015 | All other required Final inspections are complete. (This is a computer generated result) | DALE | DALE | | B= | C | 5027592 |
RAMPART CONSTRUCTION | B= | P | 06/29/2015 | . Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | DALE | DALE | | B= | P | 4983075 |
RAMPART CONSTRUCTION | B= | P | 05/18/2015 | complete roof and final grade -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | DALE | DALE | | B= | P | 4956543 |
RAMPART CONSTRUCTION | BSP | P | 04/22/2015 | fireplace frame at bonus room ok | DALE | DALE | | BSP | P | 4940414 |
RAMPART CONSTRUCTION | BSP | R | 04/21/2015 | what is inspection for? | DALE | DALE | | BSP | R | 4939703 |
RAMPART CONSTRUCTION | BLA | C | 01/27/2015 | | DALE | DALE | | BLA | C | 4891597 |
RAMPART CONSTRUCTION | BIN | C | 01/02/2015 | garage heated | DALE | DALE | | BIN | C | 4879826 |
RAMPART CONSTRUCTION | BIN | R | 12/31/2014 | not insulated under ducts at garage | DALE | DALE | | BIN | R | 4879326 |
RAMPART CONSTRUCTION | BIN | P | 12/23/2014 | basement walls OK; spraying still inprogress. heat ducts in garage soffit not cover with spray.; need to recall when done | DAN | DAN | | BIN | P | 4877434 |
RAMPART CONSTRUCTION | BIN | R | 12/19/2014 | no spray insulation ready | DALE | DALE | | BIN | R | 4875308 |
RAMPART CONSTRUCTION | BFR | C | 12/12/2014 | | DALE | DALE | | BFR | C | 4870293 |
RAMPART CONSTRUCTION | BFD | C | 12/12/2014 | | DALE | DALE | | BFD | C | 4870292 |
RAMPART CONSTRUCTION | BFT | C | 12/12/2014 | ok per eng. | DALE | DALE | | BFT | C | 4870291 |
RAMPART CONSTRUCTION | BFN | C | 12/12/2014 | ok per eng. / all paperwork on file | DALE | DALE | | BFN | C | 4870290 |
RAMPART CONSTRUCTION | BFR | R | 12/09/2014 | still need bft and bfn complete | DALE | DALE | | BFR | R | 4868184 |
RAMPART CONSTRUCTION | BSP | P | 12/09/2014 | porch ok | DALE | DALE | | BSP | P | 4868183 |
RAMPART CONSTRUCTION | BFR | R | 12/04/2014 | complete bft and bfn / strap top plates at bonus room and weld tete-posts to beam / foam and firestop | DALE | DALE | | BFR | R | 4864965 |
RAMPART CONSTRUCTION | BSP | R | 11/20/2014 | missing laterials on trusses that call ou for 2 laterial on webs | DALE | DALE | | BSP | R | 4857335 |
RAMPART CONSTRUCTION | BSP | P | 11/19/2014 | porch frames ok | DALE | DALE | | BSP | P | 4856101 |
RAMPART CONSTRUCTION | BTR | C | 11/07/2014 | | DALE | DALE | | BTR | C | 4850828 |
RAMPART CONSTRUCTION | BFI | C | 04/08/2014 | ICF | CHRISM | CHRISM | | BFI | C | 4716428 |
RAMPART CONSTRUCTION | BFD | P | 04/08/2014 | drain usable ok, need eng report for footer and foundation and copy of foundation design for file, also stamped open hole and soils report | CHRISM | CHRISM | | BFD | P | 4716426 |
RAMPART CONSTRUCTION | BFN | P | 02/19/2014 | AUTHORIZED INSPECTION BY ENGINEER | BPHILLIPS | BPHILLIPS | BPHILLIPS | BFN | P | 4689280 |
RAMPART CONSTRUCTION | BFT | P | 02/19/2014 | AUTHORIZED INSPECTION BY ENGINEER | BPHILLIPS | BPHILLIPS | BPHILLIPS | BFT | P | 4689279 |
A N' M ELECTRIC | E= | C | 05/06/2015 | pictures provided | MATTHEW | MATTHEW | | E= | C | 4949635 |
A N' M ELECTRIC | E= | P | 05/05/2015 | missing light in basement bathroom, need outlet left of basement fireplace------------------ 20 amp and 40 amp a/c's ok | MATTHEW | MATTHEW | | E= | P | 4949303 |
A N' M ELECTRIC | ER | C | 12/03/2014 | finished basement, 2 mcc's per sub-panel, 6-3nm to cooking | MATTHEW | MATTHEW | | ER | C | 4864341 |
A N' M ELECTRIC | EUG | C | 10/24/2014 | service lats | MATTHEW | MATTHEW | | EUG | C | 4841518 |
A N' M ELECTRIC | ES | C | 10/24/2014 | Residential Underground: 2-200 amp 3/w: new res------ meter is set; need seals------------ inspectors note: 2-125 amp sub-panels ok | MATTHEW | MATTHEW | | ES | C | 4841517 |
A N' M ELECTRIC | ESL | C | 05/08/2014 | 2 floor outlets with 3/4" pvc | CRAIG | CRAIG | | ESL | C | 4735400 |
A & Z MECHANICAL, INC. | H= | C | 05/15/2015 | correction made | TED | TED | | H= | C | 4955754 |
A & Z MECHANICAL, INC. | H= | R | 05/07/2015 | roof still not complete, flashings, storm collars not in place,complete guest room furnace vent outlet, missing guest room secondary a/c condensate drain, can not find 1st floor main house a/c air handler/furnace location,
| TED | TED | | H= | R | 4950803 |
A & Z MECHANICAL, INC. | H= | R | 05/05/2015 | not ready, to many items to list, (some but not all, complete roofing, complete all vent outlets, connect gas to 2nd floor guest furnace, need secondary drain on a/c coil guest furnace), reinspect all note: fireplace mantels ok | TED | TED | | H= | R | 4949388 |
A & Z MECHANICAL, INC. | HRR+ | R | 04/20/2015 | Wood burning (solid fuel) fireplace requires a BFR+ inspection. | MARK | MARK | | HRR+ | R | 4938773 |
A & Z MECHANICAL, INC. | HRR | C | 12/02/2014 | rough ok. | MARK | MARK | | HRR | C | 4862921 |
A & Z MECHANICAL, INC. | HRR | R | 11/21/2014 | I need mechanical drawings approved by RBD to do rough inspection. Not in box on tree. Not found at equipment. Trip fee waived this time. | MARK | MARK | | HRR | R | 4858281 |
R AND D PLUMBING | HWP | C | 11/20/2014 | staple down main floor ok | TIM | TIM | | HWP | C | 4857281 |
A & Z MECHANICAL, INC. | HRR | P | 11/20/2014 | could not find duct plan | TIM | TIM | | HRR | P | 4857279 |
A & Z MECHANICAL, INC. | HC | C | 11/19/2014 | Release meter for construction. | MARK | MARK | | HC | C | 4856373 |
A & Z MECHANICAL, INC. | HRR | P | 11/19/2014 | Still need to inspect rough when ready. will release construction meter. Need duct design for unit over garage vent terminations, line set for air handler. | MARK | MARK | | HRR | P | 4856371 |
A & Z MECHANICAL, INC. | HRR | P | 11/18/2014 | I didn't see plans for mechanical. I need access to upper level to see air handler. Need to seal end cap at west end of trunk in garage. Need to complete gas piping prior to rough completion. Note: Has HWP system for house with furn for guest area above garage. | MARK | MARK | | HRR | P | 4855506 |
R AND D PLUMBING | HI | C | 10/24/2014 | correction made | TED | TED | | HI | C | 4841728 |
R AND D PLUMBING | HI | P | 10/22/2014 | 10 lb test is ok. but I can't properly size the pipe system without the BTU rating of the boiler. Note: Meter to be located at road with a regulator at theb house. Will require a medium pressure system. | MARK | MARK | | HI | P | 4839776 |
R AND D PLUMBING | HI | R | 10/20/2014 | Low test. Need to know where meter will be located. If at the road, I need to know what pressure and pipe diameter size. Boiler size? Note: 2" main. 4- f/p, 1- boiler,1- rng, 2- gas dryer, future bbq at back patio. | MARK | MARK | | HI | R | 4837873 |
R AND D PLUMBING | HWP | P | 08/18/2014 | ok to cover garage floor | TED | TED | | HWP | P | 4798943 |
R AND D PLUMBING | HWP | P | 05/09/2014 | Test is ok. Ok to pour. Basement lvl. | MARK | MARK | | HWP | P | 4735884 |
R AND D PLUMBING | P= | C | 05/15/2015 | correction made | TED | TED | | P= | C | 4955762 |
R AND D PLUMBING | P= | R | 05/07/2015 | roof still not complete, missing flashings, no water to guest lav, can not have two traps on one trap arm on basement bar sink and basement bar dishwasher, (CERTIFICATE OF POTABLE WATER TO SCANNING) | TED | TED | | P= | R | 4950790 |
R AND D PLUMBING | P= | R | 05/05/2015 | not ready to many items to list, no potable water certificate, (some items but not all, complete roofing and all vent outlets, fixtures not installed, boiler vent not complete, garage hose washer not anchored), reinspect all | TED | TED | | P= | R | 4949392 |
R AND D PLUMBING | PTO | C | 10/16/2014 | NOTE : FINISHED BASEMENT , IRRIGATION STUBS , ASSURE FREEZE PROTECTION FOR TRAP IN ATTIC , POTABLE WATER CERT BY FINAL | GABE | GABE | | PTO | C | 4836003 |
R AND D PLUMBING | PWO | C | 10/03/2014 | | TIM | TIM | | PWO | C | 4828203 |
R AND D PLUMBING | PB | C | 04/30/2014 | | GABE | GABE | | PB | C | 4729818 |