EMERSON CONSTRUCTION COMPANY, LLC | B= | C | 11/05/2014 | finished basement, deck in | DALE | DALE | | B= | C | 4848767 |
EMERSON CONSTRUCTION COMPANY, LLC | B= | R | 10/30/2014 | Additional Inspections Required: Plumbing Final Inspection is not Completed yet. install house # / need cover on front window well / need egress ladder at bedroom | DALE | DALE | | B= | R | 4845196 |
EMERSON CONSTRUCTION COMPANY, LLC | BFR | C | 07/21/2014 | | DALE | DALE | | BFR | C | 4780335 |
EMERSON CONSTRUCTION COMPANY, LLC | BIN | C | 07/21/2014 | | DALE | DALE | | BIN | C | 4780563 |
EMERSON CONSTRUCTION COMPANY, LLC | BLA | C | 07/21/2014 | | DALE | DALE | | BLA | C | 4780562 |
EMERSON CONSTRUCTION COMPANY, LLC | BIN | P | 07/16/2014 | complete bfr | DALE | DALE | | BIN | P | 4778085 |
EMERSON CONSTRUCTION COMPANY, LLC | BFR | R | 07/16/2014 | need 45 on truss laterials every 20ft / need 2" clearance at fireplace flue | DALE | DALE | | BFR | R | 4778083 |
EMERSON CONSTRUCTION COMPANY, LLC | BFR | R | 07/11/2014 | ok to insulate, missing laterals C3 C4 trusses, need instructions for fireplace flues may need more clearance at roof | CHRISM | CHRISM | | BFR | R | 4775208 |
EMERSON CONSTRUCTION COMPANY, LLC | BSP | P | 07/09/2014 | deck and porch columns ok | CHRISM | CHRISM | | BSP | P | 4773311 |
EMERSON CONSTRUCTION COMPANY, LLC | BFR | R | 07/09/2014 | house locked | CHRISM | CHRISM | | BFR | R | 4773306 |
EMERSON CONSTRUCTION COMPANY, LLC | BSP | C | 05/21/2014 | deck and porch piers ok | CHRISM | CHRISM | | BSP | C | 4743080 |
EMERSON CONSTRUCTION COMPANY, LLC | BFD | C | 04/02/2014 | drain usable | CHRISM | CHRISM | | BFD | C | 4713670 |
EMERSON CONSTRUCTION COMPANY, LLC | BFN | C | 03/20/2014 | soils and design on file, need stamped open hole at drain | CHRISM | CHRISM | | BFN | C | 4705718 |
EMERSON CONSTRUCTION COMPANY, LLC | BFT | C | 03/07/2014 | 3000# bearing pads ok | CHRISM | CHRISM | | BFT | C | 4698918 |
HEADLEY ELECTRIC, LLC | E= | C | 10/01/2014 | | MATTHEW | MATTHEW | | E= | C | 4826548 |
HEADLEY ELECTRIC, LLC | E= | R | 09/30/2014 | need afci for dining room light, tandem breaker installed where not allowed in panel, cap unused wires in panel------------ no a/c, hot tub pre-wire, wet bar rough only | MATTHEW | MATTHEW | | E= | R | 4825630 |
HEADLEY ELECTRIC, LLC | ES | C | 09/30/2014 | Residential Underground: 200 amp 3/w: new res----- meter is set; need seal | MATTHEW | MATTHEW | | ES | C | 4825629 |
HEADLEY ELECTRIC, LLC | E= | L | 09/29/2014 | | MATTHEW | MATTHEW | | E= | L | 4824717 |
HEADLEY ELECTRIC, LLC | ES | L | 09/29/2014 | locked 1:15 | MATTHEW | MATTHEW | | ES | L | 4824705 |
HEADLEY ELECTRIC, LLC | ER | C | 07/01/2014 | tc cable ran into bell box outside --- 10/3 nm cable from basement to bell box | CRAIG | CRAIG | | ER | C | 4769494 |
HEADLEY ELECTRIC, LLC | EUG | C | 06/26/2014 | FROM METER PED TO HOUSE-----2--4/0 1 2/0 | BRIAN | BRIAN | | EUG | C | 4765936 |
HEADLEY ELECTRIC, LLC | ER | R | 06/26/2014 | HOUSE OK BUT NEED WELL WIRE INSTALLED ( IN A RACE WAY OR ROMEX )---------FINISHED BASEMENT------ | BRIAN | BRIAN | | ER | R | 4765929 |
O.M.A.G.M., INC. | H= | C | 10/30/2014 | Final ok. | MARK | MARK | | H= | C | 4844777 |
AFFORDABLE PLUMBING & HEAT,INC | HC | C | 07/22/2014 | RELEASE METER | JACK | JACK | | HC | C | 4781265 |
AFFORDABLE PLUMBING & HEAT,INC | HRR | C | 07/22/2014 | Boiler vent complete | JACK | JACK | | HRR | C | 4781264 |
O.M.A.G.M., INC. | HI | C | 07/08/2014 | 10 lb test ok. Note: 1" main 35' for a 85K w/h. | MARK | MARK | | HI | C | 4772384 |
AFFORDABLE PLUMBING & HEAT,INC | HRR | P | 07/01/2014 | Need to complete vent piping for boiler/water heater. Rest ok. | MARK | MARK | | HRR | P | 4769111 |
NASRALLAH PLUMBING & HEATING, INC. | HV | C | 06/24/2014 | 3 INCH PVC EXHAUST AND INTAKE . CHECK BOILER TERMINATION AT FINAL | GABE | GABE | | HV | C | 4764190 |
O.M.A.G.M., INC. | HO | C | 06/23/2014 | 255' of 1" PE pipe. Will only carry 115K at low pressure, Will need 2 lb letter at final if total BTU exceeds 115K. | MARK | MARK | | HO | C | 4763135 |
NASRALLAH PLUMBING & HEATING, INC. | HWP | C | 03/31/2014 | ok to cover basement | TED | TED | | HWP | C | 4711990 |
NASRALLAH PLUMBING & HEATING, INC. | P= | C | 11/05/2014 | received potable water cert | TIM | TIM | | P= | C | 4848466 |
NASRALLAH PLUMBING & HEATING, INC. | P= | P | 10/24/2014 | need proof of potable water | TIM | TIM | | P= | P | 4841762 |
HOMEOWNER | PWO | C | 07/08/2014 | NOTE : POTABLE WATER CERT BY FINAL | GABE | GABE | | PWO | C | 4772515 |
NASRALLAH PLUMBING & HEATING, INC. | PTO | C | 06/24/2014 | NOTE : FINISHED BASEMENT . NO IRRIGATION. POTABLE WATER CERT BY FINAL | GABE | GABE | | PTO | C | 4764181 |
NASRALLAH PLUMBING & HEATING, INC. | PB | C | 03/27/2014 | | TIM | TIM | | PB | C | 4709990 |