MASTER BILT HOMES, INC. | B= | C | 07/15/2014 | finished basement, deck in | DALE | DALE | | B= | C | 4777273 |
MASTER BILT HOMES, INC. | BLA | C | 05/29/2014 | | CHRISM | CHRISM | | BLA | C | 4747965 |
MASTER BILT HOMES, INC. | BIN | C | 05/19/2014 | | CHRISM | CHRISM | | BIN | C | 4741505 |
MASTER BILT HOMES, INC. | BFR | C | 05/15/2014 | | CHRISM | CHRISM | | BFR | C | 4739276 |
MASTER BILT HOMES, INC. | BSP | P | 05/06/2014 | front and rear porch roofs and posts ok | CHRISM | CHRISM | | BSP | P | 4733696 |
MASTER BILT HOMES, INC. | BFN | C | 03/25/2014 | design on file | CHRISM | CHRISM | | BFN | C | 4707768 |
MASTER BILT HOMES, INC. | BFD | C | 03/24/2014 | soils on file drain usable isolate and float | CHRISM | CHRISM | | BFD | C | 4706993 |
MASTER BILT HOMES, INC. | BFN | P | 03/24/2014 | eng report on file need copy of foundation design | CHRISM | CHRISM | | BFN | P | 4706992 |
MASTER BILT HOMES, INC. | BFT | C | 03/24/2014 | eng report on file | CHRISM | CHRISM | | BFT | C | 4706987 |
MASTER BILT HOMES, INC. | BSP | T | 03/18/2014 | PAID (REC#1184773) PLAN SPLICE FEE: $50 by: DALEH for Mechanical | DALEH | DALEH | | BSP | T | 4704512 |
FIRST RATE ELECTRICAL SERVICES, INC. | E= | C | 07/14/2014 | 40 amp a/c ok | MATTHEW | MATTHEW | | E= | C | 4776435 |
FIRST RATE ELECTRICAL SERVICES, INC. | E= | R | 07/08/2014 | afci breaker #10 won't trip in sub-panel----------------a/c pre-wire (a/c compressor sitting in garage) | MATTHEW | MATTHEW | | E= | R | 4772857 |
FIRST RATE ELECTRICAL SERVICES, INC. | ES | C | 05/14/2014 | Residential Underground: 200 amp 3/w: new res | MATTHEW | MATTHEW | | ES | C | 4738866 |
FIRST RATE ELECTRICAL SERVICES, INC. | ER | C | 05/14/2014 | finished basement, 80 amp sub-panel ok (2-15), 1-15 at service----------------correct outlet spacing in rec room by final | MATTHEW | MATTHEW | | ER | C | 4738856 |
FIRST RATE ELECTRICAL SERVICES, INC. | EUG | C | 05/02/2014 | 4/0 urd | TOMC | TOMC | | EUG | C | 4732200 |
DESIGN SYSTEMS HEATING & AC | H= | C | 07/10/2014 | finished basement, a/c installed, ( rheem has changed model numbers, ADP coil ok), louver door to mech. room | TED | TED | | H= | C | 4774556 |
DESIGN SYSTEMS HEATING & AC | HC | C | 05/13/2014 | RELEASE METER | TED | TED | | HC | C | 4738077 |
DESIGN SYSTEMS HEATING & AC | HRR | C | 05/13/2014 | furnace (model number ) and a/c coil manufacture are not the same as duct plan, need this corrected by final, note: finished basement, a/c rough, outside air to return, duct design | TED | TED | | HRR | C | 4737870 |
DOUBLE J GAS, INC. | HI | C | 05/09/2014 | 10 lb test ok. Note: 1" main. F, w/h, rng, f/p. | MARK | MARK | | HI | C | 4735760 |
JOLLY PLUMBING & HEATING INC. | P= | C | 07/11/2014 | NOTE : FINISHED BASEMENT . PVB INSTALLED . POTABLE WATER CERT TO SCANNING | GABE | GABE | | P= | C | 4774887 |
JOLLY PLUMBING & HEATING INC. | PTO | C | 05/05/2014 | NOTE : IRRIGATION STUB, FINISHED BASEMENT, POTABLE WATER CERTIFICATE BY FINAL | GABE | GABE | | PTO | C | 4732647 |
JOLLY PLUMBING & HEATING INC. | PWO | C | 03/31/2014 | | DICK | DICK | | PWO | C | 4711959 |
JOLLY PLUMBING & HEATING INC. | PB | C | 03/31/2014 | | DICK | DICK | | PB | C | 4711957 |