STAUFFER AND SONS CONSTRUCTION | B= | C | 07/31/2014 | All other required Final inspections are complete. (This is a computer generated result) | DALE | DALE | | B= | C | 4787850 |
STAUFFER AND SONS CONSTRUCTION | B= | P | 07/28/2014 | Additional Inspections Required: External Agency Inspection HD= by HEALTHDEPT is not Completed yet. unfinished basement | DALE | DALE | | B= | P | 4785068 |
STAUFFER AND SONS CONSTRUCTION | BLA | C | 06/06/2014 | | CHRISM | CHRISM | | BLA | C | 4752698 |
STAUFFER AND SONS CONSTRUCTION | BFR | C | 06/04/2014 | truss eng. on file | DALE | DALE | | BFR | C | 4751272 |
STAUFFER AND SONS CONSTRUCTION | BIN | P | 05/23/2014 | insulation ok, dont cover area for truss repair rest ok | CHRISM | CHRISM | | BIN | P | 4744599 |
STAUFFER AND SONS CONSTRUCTION | BFR | P | 05/23/2014 | need repair for F04 | CHRISM | CHRISM | | BFR | P | 4744598 |
STAUFFER AND SONS CONSTRUCTION | BFR | R | 05/20/2014 | ok to insulate, eng repair for F04 truss end and gusset cut, hanger dbl micro lam beams two places, hangers missing at stair hole | CHRISM | CHRISM | | BFR | R | 4741909 |
STAUFFER AND SONS CONSTRUCTION | BSP | P | 05/08/2014 | basement bearing wall and insulation in mech room ok, eng letter on file and repair ok for stacked plates at garage walls | CHRISM | CHRISM | | BSP | P | 4735012 |
STAUFFER AND SONS CONSTRUCTION | BSP | P | 04/23/2014 | porch posts, west porch posts ok, front porch posts need treated lumber | CHRISM | CHRISM | | BSP | P | 4725386 |
STAUFFER AND SONS CONSTRUCTION | BSP | P | 04/16/2014 | deck and porch piers ok | CHRISM | CHRISM | | BSP | P | 4721475 |
STAUFFER AND SONS CONSTRUCTION | BSP | R | 03/31/2014 | not ready | CHRISM | CHRISM | | BSP | R | 4711540 |
STAUFFER AND SONS CONSTRUCTION | BFD | C | 03/21/2014 | habitable drain, good / soils report and open hole report on file / 5% slope at final | JEREMYC | JEREMYC | | BFD | C | 4706189 |
STAUFFER AND SONS CONSTRUCTION | BFT | C | 03/21/2014 | footer and interior pads observation on file | JEREMYC | JEREMYC | | BFT | C | 4706188 |
STAUFFER AND SONS CONSTRUCTION | BFN | C | 03/21/2014 | foundation design and rebar observation on file / 1500psf / 1.5" float | JEREMYC | JEREMYC | | BFN | C | 4706187 |
STAUFFER AND SONS CONSTRUCTION | BFN | P | 03/05/2014 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFN | P | 4697707 |
STAUFFER AND SONS CONSTRUCTION | BFT | P | 03/05/2014 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFT | P | 4697706 |
ROWAN ELECTRIC LLC | E= | C | 07/25/2014 | no a/c | MATTHEW | MATTHEW | | E= | C | 4783899 |
ROWAN ELECTRIC LLC | ES | C | 07/24/2014 | Residential Overhead: 200 amp 3/w: new res---- meter is set; need seal | MATTHEW | MATTHEW | | ES | C | 4783286 |
ROWAN ELECTRIC LLC | E= | R | 07/24/2014 | install breaker lock for steam oven, need tr outlets in kitchen, correct closet light clearance in pink bedroom, remove gfci from behind washer, 80 amp max for sub-panel, install breaker blanks in panel on pole--------- no a/c | MATTHEW | MATTHEW | | E= | R | 4783282 |
ROWAN ELECTRIC LLC | ER | C | 05/19/2014 | NOOK WILL HAVE BUILT IN BENCH-----CONTRACTOR SAID DOORS WILL OPEN FULLY------ADDED OUTLETS IN FOYER------ | BRIAN | BRIAN | | ER | C | 4741500 |
ROWAN ELECTRIC LLC | EUG | C | 05/12/2014 | feeder from panel on pole to home ok | MATTHEW | MATTHEW | | EUG | C | 4736861 |
ROWAN ELECTRIC LLC | ER | R | 05/12/2014 | add outlets to foyer---- verify spacing for dining room countertop and around sliders not installed at this time, if garage ceiling is insulated #2 ser cable will need to be derated--------- mech room not wired | MATTHEW | MATTHEW | | ER | R | 4736855 |
BRUNO'S HEATING & COOLING | H= | C | 07/25/2014 | Has a fan and operable window. Mech rm in bsmnt is open to UB | MARK | MARK | | H= | C | 4783922 |
BRUNO'S HEATING & COOLING | H= | P | 07/22/2014 | Bath exhaust fan missing in shower portion of kids bathroom upstairs. Rest ok. | JEFFL | JEFFL | | H= | P | 4781429 |
DOUBLE J GAS, INC. | HO | C | 07/16/2014 | 10 LB. test ok. Burial depth ok. Notes-- 25' of 3/4'' installed at medium pressure to supply bbq and fire pit. | JEFFL | JEFFL | | HO | C | 4777900 |
DOUBLE J GAS, INC. | HO+ | P | 07/15/2014 | 10 LB. test ok. Burial depth required to be at least 18'' on exterior gas line. | JEFFL | JEFFL | | HO+ | P | 4776912 |
UNIQUE RADIANT HTG. & PLBG. | HO | C | 05/29/2014 | 10 LB. test ok. ***2 LB. letter needed by final. | JEFFL | JEFFL | | HO | C | 4747795 |
BRUNO'S HEATING & COOLING | HC | C | 05/19/2014 | RELEASE METER | MARK | MARK | | HC | C | 4741738 |
BRUNO'S HEATING & COOLING | HRR | C | 05/19/2014 | Rough and DD ok. Note: Check c/a to 1 w/h at final. | MARK | MARK | | HRR | C | 4741712 |
UNIQUE RADIANT HTG. & PLBG. | HWP | P | 05/14/2014 | ok to cover 1st floor | TED | TED | | HWP | P | 4738450 |
DOUBLE J GAS, INC. | HI | C | 05/07/2014 | 10lb test ok. Note: 1ea. w/h. | MARK | MARK | | HI | C | 4734146 |
UNIQUE RADIANT HTG. & PLBG. | HWP | P | 04/15/2014 | ok to cover basement | TED | TED | | HWP | P | 4720710 |
UNIQUE RADIANT HTG. & PLBG. | P= | C | 07/23/2014 | NOTE : RP IN MEC ROOM . UNFINISHED BASEMENT . POTABLE WATER CERT TO SCANNING . | GABE | GABE | | P= | C | 4782488 |
UNIQUE RADIANT HTG. & PLBG. | PTO | C | 05/16/2014 | NOTE : POTABLE WATER CERTIFICATE BY FINAL .UNFINISHED BASEMENT | GABE | GABE | | PTO | C | 4740193 |
HOMEOWNER | PWO | C | 05/14/2014 | NOTE : POTABLE WATER CERTIFICATE BY FINAL | GABE | GABE | | PWO | C | 4738324 |
UNIQUE RADIANT HTG. & PLBG. | PB | C | 04/01/2014 | | DICK | DICK | | PB | C | 4712790 |