PONDEROSA CONSTRUCTORS, LLC | B= | C | 04/15/2015 | All other required Final inspections are complete. (This is a computer generated result) | DALE | DALE | | B= | C | 4936541 |
PONDEROSA CONSTRUCTORS, LLC | BE | L | 04/15/2015 | Renewed for 1/2 Fee at 4/15/2015 7:43:54 AM (Receipt#1256250) | BPHILLIPS | BPHILLIPS | | BE | L | 4935959 |
PONDEROSA CONSTRUCTORS, LLC | B= | P | 07/24/2014 | Additional Inspections Required: Electrical Final Inspection is not Completed yet, Mechanical Final Inspection is not Completed yet, Plumbing Final Inspection is not Completed yet. complete all other inspections | DALE | DALE | | B= | P | 4783455 |
PONDEROSA CONSTRUCTORS, LLC | BFR | C | 07/21/2014 | eng. on file | DALE | DALE | | BFR | C | 4780447 |
PONDEROSA CONSTRUCTORS, LLC | BIN | R | 05/28/2014 | insulation ok, frame items not completed | CHRISM | CHRISM | | BIN | R | 4746677 |
PONDEROSA CONSTRUCTORS, LLC | BFR | R | 05/22/2014 | ok to insulate, eng truss repair for A9 and A10 ends cut, eng letter for bearing wall not per plan, bearing for CX girder not per detail | CHRISM | CHRISM | | BFR | R | 4744199 |
PONDEROSA CONSTRUCTORS, LLC | BFN | C | 05/20/2014 | eng letter on file | CHRISM | CHRISM | | BFN | C | 4741792 |
PONDEROSA CONSTRUCTORS, LLC | BFT | C | 05/20/2014 | eng letter on file | CHRISM | CHRISM | | BFT | C | 4741791 |
PONDEROSA CONSTRUCTORS, LLC | BFR | R | 05/19/2014 | not ready, eng letters for BFT and BFN on file | CHRISM | CHRISM | | BFR | R | 4741165 |
PONDEROSA CONSTRUCTORS, LLC | BFD | P | 03/07/2014 | soils and open hole on file no drain required | CHRISM | CHRISM | | BFD | P | 4698954 |
PONDEROSA CONSTRUCTORS, LLC | BFN | R | 03/07/2014 | eng inspection report needs to reference eufer ground installation, design on file | CHRISM | CHRISM | | BFN | R | 4698952 |
PONDEROSA CONSTRUCTORS, LLC | BFT | R | 03/07/2014 | eng inspection report needs to reference contractor not foundation subcontractor | CHRISM | CHRISM | | BFT | R | 4698951 |
PONDEROSA CONSTRUCTORS, LLC | BFN | P | 03/06/2014 | AUTHORIZED INSPECTION BY ENGINEER | BPHILLIPS | BPHILLIPS | BPHILLIPS | BFN | P | 4698397 |
PONDEROSA CONSTRUCTORS, LLC | BFT | P | 03/06/2014 | AUTHORIZED INSPECTION BY ENGINEER | BPHILLIPS | BPHILLIPS | BPHILLIPS | BFT | P | 4698396 |
HOMERUN ELECTRONICS, INC. | E= | C | 04/15/2015 | underground has been corrected | MATTHEW | MATTHEW | | E= | C | 4936540 |
HOMERUN ELECTRONICS, INC. | ES | C | 04/15/2015 | Residential Overhead: 200 amp 3/w: new res----- meter is set and sealed | MATTHEW | MATTHEW | | ES | C | 4936538 |
HOMERUN ELECTRONICS, INC. | E= | R | 07/23/2014 | interior of home ok----- see service | MATTHEW | MATTHEW | | E= | R | 4782576 |
HOMERUN ELECTRONICS, INC. | ES | R | 07/23/2014 | still need pole relocated where service lateral comes up and is not deep enough------ 200 amp panel ok | MATTHEW | MATTHEW | | ES | R | 4782573 |
HOMERUN ELECTRONICS, INC. | E= | R | 07/22/2014 | ground bell box by garage ------------- install gfi breaker for laundry outlet ------------- block nm cable in loft ---------------- kitchen outlet on 15 amp breaker ------------------- put hood circuit in a j-box ----------- no a/c or rough | CRAIG | CRAIG | | E= | R | 4781896 |
HOMERUN ELECTRONICS, INC. | ES | R | 07/22/2014 | Residential Underground: service lateral not deep enough ---------------- per contractor pole to be relocated | CRAIG | CRAIG | | ES | R | 4781887 |
HOMERUN ELECTRONICS, INC. | EUG | R | 06/16/2014 | only 1' deep | MATTHEW | MATTHEW | | EUG | R | 4759054 |
HOMERUN ELECTRONICS, INC. | ER | C | 05/15/2014 | crawler, 6-3nm to range | MATTHEW | MATTHEW | | ER | C | 4739491 |
BRUNO'S HEATING & COOLING | H= | C | 09/30/2014 | Meter is at house final is ok. | MARK | MARK | | H= | C | 4825171 |
BRUNO'S HEATING & COOLING | H= | R | 07/23/2014 | Gas service from main at street to house has been installed and hooked up to the meter without an inspection of pipe and trench. No test gauge on underground piping for test. | MARK | MARK | | H= | R | 4782143 |
BRUNO'S HEATING & COOLING | H= | P | 07/17/2014 | No Outside gas line to house. Final pending. Rest ok. Note: Hi/Lo grills to mech closet. No a/c, no bsmnt, unfin. bonus rm on upper level. | MARK | MARK | | H= | P | 4778809 |
BRUNO'S HEATING & COOLING | HC | C | 05/16/2014 | RELEASE METER | MARK | MARK | | HC | C | 4740061 |
BRUNO'S HEATING & COOLING | HRR | C | 05/16/2014 | Repairs made. | MARK | MARK | | HRR | C | 4740056 |
DOUBLE J GAS, INC. | HI | C | 05/15/2014 | correction made | TED | TED | | HI | C | 4739483 |
BRUNO'S HEATING & COOLING | HRR | P | 05/15/2014 | need clearance around fireplace vent to wood, need 2nd fireplace attic insulation shield | TED | TED | | HRR | P | 4739482 |
DOUBLE J GAS, INC. | HI | R | 05/14/2014 | low test, 1 1/4'' furnace, w/h, fireplace, range bbq | TED | TED | | HI | R | 4738500 |
BRUNO'S HEATING & COOLING | HRR | R | 05/13/2014 | need to finish fireplace framing, need 2nd insulation shield on fireplace vent, frame garage duct work, note: conditioned crawlspace, no a/c, outside air to return, duct design | TED | TED | | HRR | R | 4737771 |
UNIQUE RADIANT HTG. & PLBG. | P= | C | 09/29/2014 | Received Potable water certificate. | JACK | JACK | | P= | C | 4824367 |
UNIQUE RADIANT HTG. & PLBG. | P= | P | 07/23/2014 | CRAWL SPACE . NO IRRIGATION . NOTE : POTABLE WATER CERT FOR COMPLETION | GABE | GABE | | P= | P | 4782448 |
HOMEOWNER | PWO | C | 07/07/2014 | PEX UNDER FOOTER | GABE | GABE | | PWO | C | 4771870 |
UNIQUE RADIANT HTG. & PLBG. | PTO | C | 05/14/2014 | POTABLE WATER CERTIFICATE BY FINAL . | GABE | GABE | | PTO | C | 4738292 |