ALL ABOUT HOME DESIGN, LLC | B= | C | 07/31/2014 | All other required Final inspections are complete. (This is a computer generated result) | DALE | DALE | | B= | C | 4787856 |
ALL ABOUT HOME DESIGN, LLC | B= | P | 07/31/2014 | Additional Inspections Required: External Agency Inspection HD= by HEALTHDEPT is not Completed yet. finished basement, deck in | DALE | DALE | | B= | P | 4787813 |
ALL ABOUT HOME DESIGN, LLC | BSP | R | 07/25/2014 | walked with contractor | DALE | DALE | | BSP | R | 4784189 |
ALL ABOUT HOME DESIGN, LLC | BIN | C | 06/02/2014 | | CHRISM | CHRISM | | BIN | C | 4749714 |
ALL ABOUT HOME DESIGN, LLC | BFR | C | 06/02/2014 | | CHRISM | CHRISM | | BFR | C | 4749713 |
ALL ABOUT HOME DESIGN, LLC | BSP | T | 05/30/2014 | PAID (REC#1197915) ADDITIONAL PLAN REVIEW TIME: $50 From: TCRIPPEN new splice pages | TCRIPPEN | TCRIPPEN | | BSP | T | 4748262 |
ALL ABOUT HOME DESIGN, LLC | BFR | R | 05/23/2014 | ok to insulate after HRR, missing HTS20 at dbl trusses front wall, 16" oc framing over garage, floor cant second floor not on plans | CHRISM | CHRISM | | BFR | R | 4744873 |
ALL ABOUT HOME DESIGN, LLC | BFN | C | 03/31/2014 | | CHRISM | CHRISM | | BFN | C | 4711935 |
ALL ABOUT HOME DESIGN, LLC | BFI | C | 03/31/2014 | R-10 at walkout wall | CHRISM | CHRISM | | BFI | C | 4711934 |
ALL ABOUT HOME DESIGN, LLC | BFD | C | 03/28/2014 | soils on file drain usable isolate and float, need insulation at walkout wall | CHRISM | CHRISM | | BFD | C | 4710845 |
ALL ABOUT HOME DESIGN, LLC | BFN | C | 03/28/2014 | eng report on file | CHRISM | CHRISM | | BFN | C | 4710844 |
ALL ABOUT HOME DESIGN, LLC | BFT | C | 03/28/2014 | eng report on file | CHRISM | CHRISM | | BFT | C | 4710843 |
A N' M ELECTRIC | E= | C | 07/25/2014 | 2- 30 amp a/c's ok | MATTHEW | MATTHEW | | E= | C | 4784048 |
A N' M ELECTRIC | EUG | C | 06/10/2014 | service lateral from pedestal to home | MATTHEW | MATTHEW | | EUG | C | 4755242 |
A N' M ELECTRIC | ES | C | 06/10/2014 | Residential Underground: 200 amp 3/w: new res------ meter is set; need seal | MATTHEW | MATTHEW | | ES | C | 4755027 |
A N' M ELECTRIC | ER | C | 05/22/2014 | finished basement, 2-20 at sub-panel, #2al sub-panel not in insulation | MATTHEW | MATTHEW | | ER | C | 4744425 |
GROUNDHOG CONSTRUCTION | H= | C | 07/28/2014 | correction made | TED | TED | | H= | C | 4784997 |
GROUNDHOG CONSTRUCTION | H= | R | 07/25/2014 | need to complete 2nd floor furnace outlet above roof under over hang (raise it above over hang ), need condensate trap on a/c drain and secondary drain or float switch installed on 2nd floor furnace, need combustion air for water heater in basement mech. room note:finished basement, a/c installed on 2-furnaces, conditioned crawlspace with transfer openins back into house | TED | TED | | H= | R | 4784378 |
GROUNDHOG CONSTRUCTION | HC | C | 06/02/2014 | RELEASE METER | TED | TED | | HC | C | 4749546 |
GROUNDHOG CONSTRUCTION | HRR | C | 06/02/2014 | finished basement, a/c rough on 2-furnace (not on basement furnace) conditioned crawlspace | TED | TED | | HRR | C | 4749544 |
GROUNDHOG CONSTRUCTION | HRR | R | 05/23/2014 | duct lay out not to design plan, no basement design plan, need correct equipment schedule, reinspect all, talked to general contractor about doing a performance test, reinspect all | TED | TED | | HRR | R | 4745170 |
BURNS RITE GAS | HI | C | 05/21/2014 | 1 1/2'' 3-furnaces, w/h, fireplace, range dryer, bbq | TED | TED | | HI | C | 4743271 |
C & T PLUMBING, LLC. | P= | C | 07/29/2014 | . NOTE : FINISHED BASEMENT . PVB INSTALLED | GABE | GABE | | P= | C | 4785911 |
C & T PLUMBING, LLC. | PTO | C | 05/22/2014 | finished basement | TED | TED | | PTO | C | 4744271 |
C & T PLUMBING, LLC. | PTO | L | 05/21/2014 | inspection canceled by contractor | GABE | GABE | | PTO | L | 4742696 |
HOMEOWNER | PWO | C | 05/20/2014 | NOTE : POTABLE WATER CERTIFICATE BY FINAL | GABE | GABE | | PWO | C | 4741804 |
C & T PLUMBING, LLC. | PB | C | 04/02/2014 | 5 PSI DWV | GABE | GABE | | PB | C | 4713257 |