TARA CUSTOM HOMES, INC. | B= | C | 12/26/2014 | | BOBF | BOBF | | B= | C | 4878036 |
TARA CUSTOM HOMES, INC. | BLA | C | 09/12/2014 | | DALE | DALE | | BLA | C | 4815072 |
TARA CUSTOM HOMES, INC. | BIN | C | 08/29/2014 | | BOBF | BOBF | | BIN | C | 4807230 |
TARA CUSTOM HOMES, INC. | BFR | C | 08/28/2014 | | BOBF | BOBF | | BFR | C | 4806236 |
TARA CUSTOM HOMES, INC. | BIN | T | 08/28/2014 | PAID (REC#1216807) no rescheck on site / most windows have stickers removed (U factor unknown) / house is already started drywall / cannot verify insulation installation | BOBF | BOBF | | BIN | T | 4806232 |
TARA CUSTOM HOMES, INC. | BFR | P | 08/20/2014 | complete ER | DALE | DALE | | BFR | P | 4800424 |
TARA CUSTOM HOMES, INC. | BFR | R | 08/15/2014 | missing truss laterials and 45 bracing / post under girders / foam and firestop / strap top plates / complete all other inspections | DALE | DALE | | BFR | R | 4798087 |
TARA CUSTOM HOMES, INC. | BSP | P | 06/23/2014 | front and rear porch roofs and posts ok | CHRISM | CHRISM | | BSP | P | 4763183 |
TARA CUSTOM HOMES, INC. | BSP | P | 04/23/2014 | deck piers ok | CHRISM | CHRISM | | BSP | P | 4725505 |
TARA CUSTOM HOMES, INC. | BFI | C | 03/31/2014 | R-10 at walkout | CHRISM | CHRISM | | BFI | C | 4711700 |
TARA CUSTOM HOMES, INC. | BFD | P | 03/28/2014 | soils and design on file drain usable ok, need to clear BFT and BFN, no insulation at walkout do not backfill basement | CHRISM | CHRISM | | BFD | P | 4710710 |
TARA CUSTOM HOMES, INC. | BFN | P | 03/14/2014 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFN | P | 4702902 |
TARA CUSTOM HOMES, INC. | BFT | P | 03/14/2014 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFT | P | 4702901 |
MEYER ELECTRIC | E= | C | 12/23/2014 | insta hot has been removed | MATTHEW | MATTHEW | | E= | C | 4877289 |
MEYER ELECTRIC | E= | T | 12/22/2014 | PAID (REC#1238533): need dead face gfci for spa, install correct size main bonding jumper (#4cu), insta hot pulls 6.5 amps; dish and disposal pull 17.8 amps; need additional circuit for insta hot | MATTHEW | MATTHEW | | E= | T | 4876316 |
MEYER ELECTRIC | E= | R | 12/19/2014 | for spa outlet need outlet turned to opening and gfci protection needs to be moved to panel, need light at stairs installed to check 3 ways, trim outlet in bedroom behind door, need info on insta hot being installed on dish disposal circuit (17.8 total amps on dish disp ckt), remove chandelier over tub, lamp lights on deck, install main bonding jumper in panel or install grounding electrode conductor directly to neutral bar--, switch for vanity lights not installed in master bath--------------------- a/c pre-wire | MATTHEW | MATTHEW | | E= | R | 4875672 |
MEYER ELECTRIC | E= | R | 12/05/2014 | not ready------ complete re-inspect------ partial list: no power to exterior outlets, no power to outlet on kitchen island or small kitchen counter, back outlet loose, 40 amp max for oven, wire hanging at hood and front exterior light not installed, 14-2 on 20 amp breaker, no gfci protection for single outlet left of panel, provide means to check OH door, outlet in basement bedroom not trimmed, no power to bath outlet in basement, open bulbs in clothes closet, install main bonding jumper in panel or move grounding electrode conductor to neutral, switch being added to vanity lights in master bath needs to be completed and not on bath circuit, breaker labeled tub and no outlet at any tub?---------------- complete re-inspect | MATTHEW | MATTHEW | | E= | R | 4866442 |
MEYER ELECTRIC | ES | C | 12/05/2014 | Residential Underground: 200 amp 3/w: new res------- meter is set; need seal | MATTHEW | MATTHEW | | ES | C | 4866431 |
MEYER ELECTRIC | ER | C | 08/26/2014 | nm to well | MATTHEW | MATTHEW | | ER | C | 4803990 |
MEYER ELECTRIC | ER | P | 08/22/2014 | wiring from well to home still not installed | MATTHEW | MATTHEW | | ER | P | 4802502 |
MEYER ELECTRIC | ER | P | 08/15/2014 | talked to contractor about well wiring; needs to be installed before rough is completed | MATTHEW | MATTHEW | | ER | P | 4797580 |
MEYER ELECTRIC | ER | R | 08/11/2014 | wiring from well not installed | MATTHEW | MATTHEW | | ER | R | 4794507 |
MEYER ELECTRIC | ER | R | 08/04/2014 | correct wall spacing in living room at windows, boxes and wiring in return air in basement hallway, well contractor needs to install wiring to well --------------finished basement, 2-20 at service #6al------------ #6 al sub-panel ok (not breakered) | MATTHEW | MATTHEW | | ER | R | 4789690 |
MEYER ELECTRIC | EUG | C | 04/18/2014 | service lateral from pedestal to home | MATTHEW | MATTHEW | | EUG | C | 4723224 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 12/19/2014 | Corrections made. | MICHAELS | MICHAELS | | H= | C | 4875459 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | P | 12/18/2014 | Remove stucco from furnace termination, complete range hood, rest ok. Note: louvered door to mech, finished basement, a/c rough(coil and lineset), mantel ok. | MICHAELS | MICHAELS | | H= | P | 4874571 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | L | 12/17/2014 | Field cancelled, not ready. | MICHAELS | MICHAELS | | H= | L | 4873432 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HC | C | 08/06/2014 | RELEASE METER | JEFFL | JEFFL | | HC | C | 4791426 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 08/06/2014 | B vent is contacting plastic water pipe in mech room and needs corrected by final. Rest ok. ** Equipment cert needed by final. Notes-- finished basement.. OSA to return.. AC rough.. Duct design.. Direct vent furnace.. | JEFFL | JEFFL | | HRR | C | 4791420 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | L | 08/04/2014 | Field cancelled. | JEFFL | JEFFL | | HRR | L | 4789627 |
O.M.A.G.M., INC. | HI | C | 07/24/2014 | 10 LB. test ok. Notes-- 1 1/4'' main.. 1 furnace.. 2 wh.. 1 range.. 1 fp..1 bbq | JEFFL | JEFFL | | HI | C | 4783442 |
UNIQUE RADIANT HTG. & PLBG. | P= | C | 12/19/2014 | | TIM | TIM | | P= | C | 4875009 |
UNIQUE RADIANT HTG. & PLBG. | P= | P | 12/16/2014 | need potable water cert, cap open bar drain ok to e-mail wtr cert and pics of cap on drain | TIM | TIM | | P= | P | 4872508 |
UNIQUE RADIANT HTG. & PLBG. | PTO | C | 08/01/2014 | NOTE : FINISHED BASEMENT . IRRIGATION STUB . POTABLE WATER CERT BY FINAL | GABE | GABE | | PTO | C | 4788697 |
UNIQUE RADIANT HTG. & PLBG. | PWO | C | 04/23/2014 | POTABLE WATER CERTIFICATE BY FINAL | GABE | GABE | | PWO | C | 4725522 |
UNIQUE RADIANT HTG. & PLBG. | PB | C | 04/17/2014 | | GABE | GABE | | PB | C | 4721881 |