PREMIER HOMES, INC. | B= | C | 08/29/2014 | items corrected. | NATHAN | NATHAN | | B= | C | 4807121 |
PREMIER HOMES, INC. | BSP | P | 08/28/2014 | Splice: Revised header for walkout | DANM | DANM | | BSP | P | 4805778 |
PREMIER HOMES, INC. | B= | P | 08/25/2014 | engineer letter for header in basement on file / post address on house -- Schedule a new Building Final when above items are complete. | BOBF | BOBF | | B= | P | 4803475 |
PREMIER HOMES, INC. | BSP | P | 07/28/2014 | deck okay including stairs | BOBF | BOBF | | BSP | P | 4784781 |
PREMIER HOMES, INC. | BSP | C | 06/20/2014 | | BOBF | BOBF | | BSP | C | 4762093 |
PREMIER HOMES, INC. | BFR | P | 06/17/2014 | provide eng letter for 9 1/2" ML in lieu of 11 7/8" ml header | BOBF | BOBF | | BFR | P | 4759556 |
PREMIER HOMES, INC. | BIN | C | 06/17/2014 | | BOBF | BOBF | | BIN | C | 4759555 |
PREMIER HOMES, INC. | BFR | P | 06/16/2014 | provide approved walkout plans / 3 trimmers each end under double microlam on north end / 3 kings each end of ML south side of house / missing pipe jacks / okay to insulate | BOBF | BOBF | | BFR | P | 4758655 |
PREMIER HOMES, INC. | BSP | P | 05/15/2014 | narrow wall okay | BOBF | BOBF | | BSP | P | 4739194 |
PREMIER HOMES, INC. | BSP | P | 05/14/2014 | porch okay / narrow wall needs to be nailed per detail on plans | BOBF | BOBF | | BSP | P | 4738547 |
PREMIER HOMES, INC. | BSP | R | 05/13/2014 | no plans for porch reject / sheer okay | NATHAN | NATHAN | | BSP | R | 4737449 |
PREMIER HOMES, INC. | BFD | C | 04/17/2014 | exterior / entire foundation / open hole and design on file 2200/2000 / ISO 1 1/2" float / 10% slope | BOBF | BOBF | | BFD | C | 4722135 |
PREMIER HOMES, INC. | BFI | C | 04/17/2014 | | BOBF | BOBF | | BFI | C | 4722042 |
PREMIER HOMES, INC. | BFN | C | 04/15/2014 | | BOBF | BOBF | | BFN | C | 4720322 |
PREMIER HOMES, INC. | BFT | C | 04/11/2014 | | BOBF | BOBF | | BFT | C | 4718758 |
SEDLAK ELECTRIC CO. | E= | C | 07/28/2014 | A/C PRE-WIRE ONLY--- | TIMA | TIMA | | E= | C | 4785221 |
SEDLAK ELECTRIC CO. | ER | C | 06/11/2014 | NO MULTI WIRE #6 AL----UNFINISHED BASEMENT--- | TIMA | TIMA | | ER | C | 4755924 |
SEDLAK ELECTRIC CO. | ES | C | 06/11/2014 | Residential Underground: 150 AMP 3/W NEW RES. NEEDS METER SEAL | TIMA | TIMA | | ES | C | 4755886 |
SEDLAK ELECTRIC CO. | EUG | C | 05/29/2014 | FROM METER PED TO HOUSE-----OK | BRIAN | BRIAN | | EUG | C | 4747355 |
BRUNO'S HEATING & COOLING | H= | C | 07/15/2014 | OK NOTE UNFINISHED BASEMENT , NO A/C ATTIC OSA | DAVIDH | DAVIDH | | H= | C | 4776809 |
BRUNO'S HEATING & COOLING | HC | C | 06/13/2014 | RELEASE METER | DAVIDH | DAVIDH | | HC | C | 4757371 |
BRUNO'S HEATING & COOLING | HRR | C | 06/13/2014 | OK NOTE EQUIP CHECK OK UNFINISHED BASEMENT 6"OSA NO A/C | DAVIDH | DAVIDH | | HRR | C | 4757370 |
JESS' PLUMBING & HEATING, INC | HI | C | 06/11/2014 | Corrections made | MARKB | MARKB | | HI | C | 4755587 |
JESS' PLUMBING & HEATING, INC | HI | P | 06/09/2014 | Need nail protection on top plate to furnace at main level. Can not strap pipe in wall unless nail protected. 10 psi test OK. Note: Hybrid system - 11/4" black to Gastite branches for furnace and water heater | MARKB | MARKB | | HI | P | 4753842 |
JESS' PLUMBING & HEATING, INC | HI | R | 06/05/2014 | 55 psi test on 160 psi gauge. REQUIRE - 10 PSI TEST ON 15 OR 30 PSI GAUGE | MARKB | MARKB | | HI | R | 4752143 |
JESS' PLUMBING & HEATING, INC | HI | T | 06/03/2014 | PAID (REC#1198690): Low test. gauge at zero | MARKB | MARKB | | HI | T | 4750524 |
JESS' PLUMBING & HEATING, INC | HI | R | 06/02/2014 | Not Ready. No main line | MARKB | MARKB | | HI | R | 4749407 |
JESS' PLUMBING & HEATING, INC | P= | C | 08/22/2014 | unfinished basement, pvb installed. | DICK | DICK | | P= | C | 4802760 |
JESS' PLUMBING & HEATING, INC | P= | T | 08/21/2014 | PAID (REC#1215342): house locked 3:50 | DICK | DICK | | P= | T | 4801846 |
JESS' PLUMBING & HEATING, INC | P= | R | 08/20/2014 | HOUSE LOCKED 3:35. | DICK | DICK | | P= | R | 4800860 |
JESS' PLUMBING & HEATING, INC | P= | R | 08/12/2014 | no water. no back flow prevention for irrigation. | DICK | DICK | | P= | R | 4795603 |
JESS' PLUMBING & HEATING, INC | PTO | C | 06/05/2014 | correction made. | DICK | DICK | | PTO | C | 4752433 |
JESS' PLUMBING & HEATING, INC | PTO | P | 06/03/2014 | still need boca plates at bottom of walls. water size ok, meter loop? | DICK | DICK | | PTO | P | 4750630 |
JESS' PLUMBING & HEATING, INC | PTO | P | 06/02/2014 | need boca plates at floor and ceiling, check water pipe sizing. | DICK | DICK | | PTO | P | 4749711 |
JESS' PLUMBING & HEATING, INC | PB | C | 04/22/2014 | | JOEL | JOEL | | PB | C | 4725115 |