TIFFANY HOMES, LLC. | B= | C | 08/29/2014 | | CHRISM | CHRISM | | B= | C | 4807197 |
TIFFANY HOMES, LLC. | BSP | P | 08/28/2014 | courtesy prewalk for final / complete guard rails at deck and stairs / eladders at bedroom window wells / complete exterior siding | BOBF | BOBF | | BSP | P | 4806269 |
TIFFANY HOMES, LLC. | BLA | C | 07/11/2014 | | CHRISM | CHRISM | | BLA | C | 4775053 |
TIFFANY HOMES, LLC. | BIN | C | 06/27/2014 | | CHRISM | CHRISM | | BIN | C | 4767084 |
TIFFANY HOMES, LLC. | BFR | C | 06/27/2014 | | CHRISM | CHRISM | | BFR | C | 4767080 |
TIFFANY HOMES, LLC. | BFR | P | 06/20/2014 | engineer repair for trusses on file, add HTS20's at girders in garage, check draftstopping at BIN, missing vertical bearing block at C2 girder , add (2) h2.5's at front porch, cut out over framing, rear porch lid - post connections ok, add hanger at glue lam beam at rear deck framing, other items completed during inspection. ok to insulate | ED | ED | | BFR | P | 4762524 |
TIFFANY HOMES, LLC. | BSP | P | 05/14/2014 | deck piers ok | CHRISM | CHRISM | | BSP | P | 4738371 |
TIFFANY HOMES, LLC. | BSP | R | 05/13/2014 | canceled at site | CHRISM | CHRISM | | BSP | R | 4737543 |
TIFFANY HOMES, LLC. | BSP | R | 05/12/2014 | cancelled in the field | ED | ED | | BSP | R | 4736933 |
TIFFANY HOMES, LLC. | BFD | C | 04/17/2014 | soils on file drain usable isolate and float | CHRISM | CHRISM | | BFD | C | 4722223 |
TIFFANY HOMES, LLC. | BFN | C | 04/17/2014 | design and eng report on file | CHRISM | CHRISM | | BFN | C | 4722196 |
TIFFANY HOMES, LLC. | BFT | C | 04/17/2014 | eng report on file | CHRISM | CHRISM | | BFT | C | 4722191 |
TIFFANY HOMES, LLC. | BFN | P | 03/21/2014 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFN | P | 4706442 |
TIFFANY HOMES, LLC. | BFT | P | 03/21/2014 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFT | P | 4706441 |
D & J QUALITY ELECTRIC INC | E= | C | 08/28/2014 | corrections made | TOMC | TOMC | | E= | C | 4805603 |
D & J QUALITY ELECTRIC INC | E= | P | 08/27/2014 | bond ground in well disconnect | MATTHEW | MATTHEW | | E= | P | 4805269 |
D & J QUALITY ELECTRIC INC | E= | R | 08/26/2014 | afci wet bar, room locked in basement at bottom of stairs, service neutral not completely in lug in panel----------- no a/c----------- future generator set up | MATTHEW | MATTHEW | | E= | R | 4804042 |
D & J QUALITY ELECTRIC INC | ES | C | 07/29/2014 | Residential Underground: 200 amp 3/w: new res------ need meter set and seal---------------- inspectors note: service neutral not completely in lug; check at final | MATTHEW | MATTHEW | | ES | C | 4786224 |
D & J QUALITY ELECTRIC INC | EUG | C | 07/22/2014 | service lateral from pedestal to home ok | MATTHEW | MATTHEW | | EUG | C | 4781842 |
D & J QUALITY ELECTRIC INC | ER | C | 06/17/2014 | finished basement, 8-3 nm to cooking, 6-3 nm to gen panel (genset breaker needs to be secured to panel) | MATTHEW | MATTHEW | | ER | C | 4759687 |
BRUNO'S HEATING & COOLING | H= | C | 08/27/2014 | Corrections made. | JEFFL | JEFFL | | H= | C | 4805281 |
BRUNO'S HEATING & COOLING | H= | P | 08/26/2014 | Need to complete vent terminations, need Hi/Lo grills (12x12 min) Need gas connected to house. rest ok. Note: Fin B, line set rough only. Has louver door to mech and direct vent furn (2). | MARK | MARK | | H= | P | 4803895 |
BRUNO'S HEATING & COOLING | HC | C | 06/19/2014 | RELEASE METER | MARK | MARK | | HC | C | 4761467 |
BRUNO'S HEATING & COOLING | HRR | C | 06/19/2014 | Rough and duct design are good. Fin Bsmnt no a/c No OSA. | MARK | MARK | | HRR | C | 4761459 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | HI | C | 06/18/2014 | 10 lb test ok. Note: 1 1/4" main. (2) furn, (1) w/h, bbq, f/p, cook top, future garage heater. | MARK | MARK | | HI | C | 4760370 |
BRUNO'S HEATING & COOLING | HRR | L | 06/17/2014 | No prints found on site. Trip waived. | MARK | MARK | | HRR | L | 4759507 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | P= | C | 08/27/2014 | NOTE : FINISHED BASEMENT . NO IRRIGATION . POTABLE WATER CERT TO SCANNING | GABE | GABE | | P= | C | 4805091 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PTO | C | 06/18/2014 | NOTE : FINISHED BASEMENT . NO IRRIGATION . POTABLE WATER CERT BY FINAL | GABE | GABE | | PTO | C | 4760310 |
HOMEOWNER | PWO | C | 06/09/2014 | POTABLE WATER CERT TO SCANNING | GABE | GABE | | PWO | C | 4753775 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PB | C | 04/25/2014 | | GABE | GABE | | PB | C | 4726987 |