BISON BUILDERS & ASSOCIATES, INC. | B= | C | 12/08/2014 | | NICK | NICK | | B= | C | 4867244 |
BISON BUILDERS & ASSOCIATES, INC. | B= | P | 11/25/2014 | Additional Inspections Required: External Agency Inspection HD= by HEALTHDEPT is not Completed yet. missing C/O alarm in g=basement, and guardrail to lower level stairs not installed - finished basement, rear deck -- Schedule a new Building Final when above items are complete. | ED | ED | | B= | P | 4860363 |
BISON BUILDERS & ASSOCIATES, INC. | B= | R | 11/14/2014 | Additional Inspections Required: External Agency Inspection HD= by HEALTHDEPT is not Completed yet. cancelled in the field | ED | ED | | B= | R | 4853619 |
BISON BUILDERS & ASSOCIATES, INC. | BLA | C | 09/15/2014 | | ED | ED | | BLA | C | 4816238 |
BISON BUILDERS & ASSOCIATES, INC. | BSP | T | 09/11/2014 | PAID (REC#1219259) PLAN SPLICE FEE: $50 by: JIMA for Construction: splice : to detached garage - added windows and porch cover | JIMA | JIMA | | BSP | T | 4813873 |
BISON BUILDERS & ASSOCIATES, INC. | BFR | C | 08/28/2014 | engineer repair letter for truss on file | ED | ED | | BFR | C | 4806280 |
BISON BUILDERS & ASSOCIATES, INC. | BIN | C | 08/28/2014 | | ED | ED | | BIN | C | 4806279 |
BISON BUILDERS & ASSOCIATES, INC. | BIN | R | 08/27/2014 | not complete | DALE | DALE | | BIN | R | 4805301 |
BISON BUILDERS & ASSOCIATES, INC. | BFR | P | 08/27/2014 | need truss eng. | DALE | DALE | | BFR | P | 4805300 |
BISON BUILDERS & ASSOCIATES, INC. | BFR | P | 08/22/2014 | missing hanger at floor joist above stair opening, secure mono posts in basement, check air barriers at insulation, need engineer truss repair DO2 truss - damaged gusset ok to insulate | ED | ED | | BFR | P | 4802784 |
BISON BUILDERS & ASSOCIATES, INC. | BSP | T | 08/12/2014 | PAID (REC#1213514) PLAN SPLICE FEE: $50 by: MICHAEL for Construction: Enlarge deck | MICHAELA | MICHAELA | | BSP | T | 4795553 |
BISON BUILDERS & ASSOCIATES, INC. | BSP | P | 07/31/2014 | porch lids ok / porch piers ok | DALE | DALE | | BSP | P | 4787885 |
BISON BUILDERS & ASSOCIATES, INC. | BFI | C | 04/15/2014 | R-10 at walkout | CHRISM | CHRISM | | BFI | C | 4720536 |
BISON BUILDERS & ASSOCIATES, INC. | BFD | C | 04/15/2014 | | CHRISM | CHRISM | | BFD | C | 4720535 |
BISON BUILDERS & ASSOCIATES, INC. | BFN | C | 04/10/2014 | eufer ground ok, foundation design and soils on file-- drain habitable- | ED | ED | | BFN | C | 4718567 |
BISON BUILDERS & ASSOCIATES, INC. | BFT | C | 04/08/2014 | 1500 psf, interior pads ok | ED | ED | | BFT | C | 4716037 |
ALTHOUSE ELECTRIC, INC. | E= | C | 11/13/2014 | 40 amp breaker for ac unit | JOSEPH | JOSEPH | | E= | C | 4853396 |
ALTHOUSE ELECTRIC, INC. | EUG | C | 09/02/2014 | | JOSEPH | JOSEPH | | EUG | C | 4808007 |
ALTHOUSE ELECTRIC, INC. | ES | C | 09/02/2014 | Residential Underground: 200 amp 3w new res meter in need to reseal | JOSEPH | JOSEPH | | ES | C | 4808006 |
ALTHOUSE ELECTRIC, INC. | ER | C | 08/21/2014 | 4/w # 2 al to sub panel in finished basement check on final 8/3 cu to range 2 - 10/3 to both dryer 6/3 al to a/c well wire is in uf cable | CRAIG | CRAIG | | ER | C | 4801890 |
BROWN'S HEATING & COOLING, INC | H= | C | 11/07/2014 | finished basement a/c to main furnace, mech room large enough to not require additional c/a | TIM | TIM | | H= | C | 4850624 |
J & J MECHANICAL, INC | HI+ | C | 10/03/2014 | 10 LB TEST IS OK. FROM OUTDOOR F/P TO BBQ. | MARK | MARK | | HI+ | C | 4828250 |
J & J MECHANICAL, INC | HI+ | P | 10/02/2014 | could not find new gas outlet, no test on the system, finished basement need more info and test | TIM | TIM | | HI+ | P | 4827701 |
BROWN'S HEATING & COOLING, INC | HC | C | 08/22/2014 | RELEASE METER | TED | TED | | HC | C | 4802293 |
BROWN'S HEATING & COOLING, INC | HRR | C | 08/22/2014 | correction made, note: patio fireplace has not been installed at this time, if it is installed under this permit an hrr+ and an hi+ inspection will be needed | TED | TED | | HRR | C | 4802292 |
BROWN'S HEATING & COOLING, INC | HRR | P | 08/19/2014 | seal returns through out in basement ceiling, roof paper on b vent, note: finished basement, outside air to both furnaces, a/c rough main furnace only, duct design | TED | TED | | HRR | P | 4799886 |
J & J MECHANICAL, INC | HI | C | 08/12/2014 | 1 1/4'' 2-furnaces, w/h, 3-fireplaces, 1 outlet on rear of house for bbq and outdoor fireplace | TED | TED | | HI | C | 4795453 |
JOLLY PLUMBING & HEATING INC. | P= | C | 11/12/2014 | r-p installed | TIM | TIM | | P= | C | 4852771 |
JOLLY PLUMBING & HEATING INC. | P= | P | 11/07/2014 | received potable water cert | TIM | TIM | | P= | P | 4850276 |
JOLLY PLUMBING & HEATING INC. | PTO | C | 08/01/2014 | | TIM | TIM | | PTO | C | 4788905 |
JOLLY PLUMBING & HEATING INC. | PB | C | 04/28/2014 | | TIM | TIM | | PB | C | 4728677 |
JOLLY PLUMBING & HEATING INC. | PB | P | 04/25/2014 | 3" stack comes off up stream of vent for water closet, need psi rating for pvc wtr service need to be 160 psi min | TIM | TIM | | PB | P | 4727567 |