PIONEER WEST HOMES LLC | B= | C | 11/10/2014 | all other field insp complete | JOHN | JOHN | | B= | C | 4851616 |
PIONEER WEST HOMES LLC | BSP | C | 11/06/2014 | | BOBF | BOBF | | BSP | C | 4849929 |
PIONEER WEST HOMES LLC | B= | P | 11/05/2014 | Additional Inspections Required: Plumbing Final Inspection is not Completed yet. provide insulation cert / front porch exceeds 30" above grade, provide guard rail or raise final grade -- Schedule a new Building Final when above items are complete. | BOBF | BOBF | | B= | P | 4848558 |
PIONEER WEST HOMES LLC | BLA | C | 09/12/2014 | | DALE | DALE | | BLA | C | 4814827 |
PIONEER WEST HOMES LLC | BFR | C | 08/27/2014 | | DALE | DALE | | BFR | C | 4804721 |
PIONEER WEST HOMES LLC | BFR | R | 08/21/2014 | not complete | DALE | DALE | | BFR | R | 4801193 |
PIONEER WEST HOMES LLC | BFR | R | 08/20/2014 | complete all other inspections / block garage door brackets / HTS 12 at truss girder / FHA plate at plumbing / strap stair landing / stair rise 7 3/4" max. / fireblock fireplace and can not see spark shield | DALE | DALE | | BFR | R | 4800555 |
PIONEER WEST HOMES LLC | BIN | P | 08/20/2014 | Qualified third party energy inspection documentation must be presented at time of final building (B=) inspection | KENYATTA | KENYATTA | | BIN | P | 4800086 |
PIONEER WEST HOMES LLC | BSP | T | 07/21/2014 | PAID (REC#1209541) PLAN SPLICE FEE: $50 by: DALEH for Mechanical: Changed equipment. | DALEH | DALEH | | BSP | T | 4780821 |
PIONEER WEST HOMES LLC | BFI | C | 05/23/2014 | ICF | CHRISM | CHRISM | | BFI | C | 4744663 |
PIONEER WEST HOMES LLC | BFD | C | 05/23/2014 | soils on file drain usable isolate and float | CHRISM | CHRISM | | BFD | C | 4744662 |
PIONEER WEST HOMES LLC | BFN | C | 05/23/2014 | eng report on file | CHRISM | CHRISM | | BFN | C | 4744661 |
PIONEER WEST HOMES LLC | BFT | C | 05/23/2014 | eng report on file | CHRISM | CHRISM | | BFT | C | 4744656 |
PIONEER WEST HOMES LLC | BFN | P | 05/23/2014 | AUTHORIZED INSPECTION BY ENGINEER | TERRI | TERRI | TERRI | BFN | P | 4744484 |
PIONEER WEST HOMES LLC | BFT | P | 05/23/2014 | AUTHORIZED INSPECTION BY ENGINEER | TERRI | TERRI | TERRI | BFT | P | 4744483 |
PIONEER WEST HOMES LLC | BFD | R | 05/21/2014 | no paperwork on site, need eng reports and soils and open hole | CHRISM | CHRISM | | BFD | R | 4742960 |
FOUNTAIN VALLEY ELECTRICAL, LLC | E= | C | 11/03/2014 | | CRAIG | CRAIG | | E= | C | 4846778 |
FOUNTAIN VALLEY ELECTRICAL, LLC | E= | R | 10/31/2014 | kitchen gfci won't set, no power to rec room smoke, label detached garage disconnect (the one that looks like the service disconnect)------------------ a/c and hot tub pre-wires | MATTHEW | MATTHEW | | E= | R | 4846604 |
FOUNTAIN VALLEY ELECTRICAL, LLC | ES | C | 08/06/2014 | Residential Underground: 200 amp 3/w: new res----- meter is set; need seal | MATTHEW | MATTHEW | | ES | C | 4791722 |
FOUNTAIN VALLEY ELECTRICAL, LLC | ER | C | 08/06/2014 | service lateral ditch where caution tape was added was backfilled before inspection; need to pothole | MATTHEW | MATTHEW | | ER | C | 4791721 |
FOUNTAIN VALLEY ELECTRICAL, LLC | ES | R | 08/05/2014 | need conduit sealed to prevent water from entering panel, where's the caution tape? | MATTHEW | MATTHEW | | ES | R | 4790474 |
FOUNTAIN VALLEY ELECTRICAL, LLC | ER | R | 08/05/2014 | remove paint under ground lug at exterior disconnect, ground metal box at fireplace, are the dryer and cooktop gas?--------- finished basement, #6al to oven, 6-3nm stub out | MATTHEW | MATTHEW | | ER | R | 4790472 |
FOUNTAIN VALLEY ELECTRICAL, LLC | EUG | C | 07/10/2014 | service lateral from pedestal to home | MATTHEW | MATTHEW | | EUG | C | 4774544 |
ROBBINS HEATING & AIR CONDITIONING, INC. | H= | C | 11/04/2014 | Corrections completed. Final ok. | MARK | MARK | | H= | C | 4848336 |
FLOW RIGHT PLUMBING HEATING & IRRIGATION, INC. | H= | R | 11/03/2014 | Line set still needs to be supported in mech rm. Insulation still needs to be completed at a/c coil. All exposed piping is labeled. | MARK | MARK | | H= | R | 4846861 |
ROBBINS HEATING & AIR CONDITIONING, INC. | H= | P | 10/29/2014 | Support lineset in mech as noted at rough and extend insulation to face of coil, laundry lacks make-up air, make final gas connections and label all exposed piping medium pressure. Note: finished basement, direct vent appliances, a/c rough(coil and lineset), fireplaces are wood burning. | MICHAELS | MICHAELS | | H= | P | 4844508 |
FLOW RIGHT PLUMBING HEATING & IRRIGATION, INC. | HC | C | 08/19/2014 | RELEASE METER | JEFFL | JEFFL | | HC | C | 4799597 |
FLOW RIGHT PLUMBING HEATING & IRRIGATION, INC. | HI | C | 08/19/2014 | 10 LB. test ok. Notes-- 2LB. system.. 1 furnace.. 1 wh.. 1 range.. 1 bbq. 1 dryer | JEFFL | JEFFL | | HI | C | 4799588 |
ROBBINS HEATING & AIR CONDITIONING, INC. | HRR | C | 08/04/2014 | **Support required on line set in mech room by final. Rest ok. Notes-- finished basement.. AC rough.. Duct design.. Equipment cert to scanning. | JEFFL | JEFFL | | HRR | C | 4789736 |
FLOW RIGHT PLUMBING HEATING & IRRIGATION, INC. | HO | C | 07/11/2014 | 10lb test ok. Note: 225' from meter at road to house. 75 feet from house to garage all on 3/4" PE pipe. | MARK | MARK | | HO | C | 4774989 |
FLOW RIGHT PLUMBING HEATING & IRRIGATION, INC. | P= | C | 11/06/2014 | received potable water cert | TIM | TIM | | P= | C | 4849371 |
FLOW RIGHT PLUMBING HEATING & IRRIGATION, INC. | P= | P | 11/03/2014 | need proof of potable water | TIM | TIM | | P= | P | 4847200 |
FLOW RIGHT PLUMBING HEATING & IRRIGATION, INC. | PTO | C | 08/25/2014 | | TIM | TIM | | PTO | C | 4803311 |
FLOW RIGHT PLUMBING HEATING & IRRIGATION, INC. | PTO | P | 08/19/2014 | pb not passed, anchor basement closet flanges | TIM | TIM | | PTO | P | 4799732 |
FLOW RIGHT PLUMBING HEATING & IRRIGATION, INC. | PWO | C | 07/15/2014 | CORRECTIONS MADE | GABE | GABE | | PWO | C | 4776893 |
FLOW RIGHT PLUMBING HEATING & IRRIGATION, INC. | PWO | P | 07/11/2014 | DEPTH AT GARAGE NO SUFFICIENT , NEED TO SEE WELL CONNECTION , BACK FLOW REQUIRED FOR YARD HYDRANT . PEX SLEEVED AT HOUSE FOUNDATION . NOTE : POTABLE WATER CERT BY FINAL | GABE | GABE | | PWO | P | 4775169 |
FLOW RIGHT PLUMBING HEATING & IRRIGATION, INC. | PTO | R | 07/10/2014 | not ready pto not even started | TIM | TIM | | PTO | R | 4774629 |
FLOW RIGHT PLUMBING HEATING & IRRIGATION, INC. | PB | C | 05/30/2014 | | GABE | GABE | | PB | C | 4748286 |