PIONEER WEST HOMES LLC | B= | C | 08/11/2015 | | JOHN | JOHN | | B= | C | 5012448 |
PIONEER WEST HOMES LLC | B= | P | 11/05/2014 | Additional Inspections Required: FLOW RIGHT PLBG HTG & IRR INC. Mechanical Final Inspection is not Completed yet, ROBBINS HTG & AIR COND INC Mechanical Final Inspection is not Completed yet. building okay pending H= | BOBF | BOBF | | B= | P | 4848560 |
PIONEER WEST HOMES LLC | BLA | C | 09/12/2014 | | DALE | DALE | | BLA | C | 4814828 |
PIONEER WEST HOMES LLC | BFR | C | 08/27/2014 | | DALE | DALE | | BFR | C | 4804732 |
PIONEER WEST HOMES LLC | BFR | R | 08/21/2014 | complete all other inspections / strong back gable ends / 45 brace gables / missing anchors | DALE | DALE | | BFR | R | 4801205 |
PIONEER WEST HOMES LLC | BFN | C | 05/23/2014 | eng report on file, soils on file no drain required | CHRISM | CHRISM | | BFN | C | 4744750 |
PIONEER WEST HOMES LLC | BFT | C | 05/23/2014 | eng report on file | CHRISM | CHRISM | | BFT | C | 4744749 |
FOUNTAIN VALLEY ELECTRICAL, LLC | E= | C | 11/03/2014 | | CRAIG | CRAIG | | E= | C | 4846782 |
FOUNTAIN VALLEY ELECTRICAL, LLC | EP | C | 08/20/2014 | 125 amp sub-panel ok | MATTHEW | MATTHEW | | EP | C | 4800572 |
FOUNTAIN VALLEY ELECTRICAL, LLC | EP | R | 08/19/2014 | install main at garage (16 circuits); completely remove paint under lug in disconnect at house | MATTHEW | MATTHEW | | EP | R | 4799882 |
FOUNTAIN VALLEY ELECTRICAL, LLC | EUG | C | 08/19/2014 | 2/0al feeder from house to garage ok | MATTHEW | MATTHEW | | EUG | C | 4799877 |
FOUNTAIN VALLEY ELECTRICAL, LLC | ES | R | 08/14/2014 | did not inspect; equipment ground missing, contractor needs to check before recall | MATTHEW | MATTHEW | | ES | R | 4797252 |
FOUNTAIN VALLEY ELECTRICAL, LLC | EUG | T | 08/14/2014 | PAID (REC#1214426): equipment ground still not installed, feeder wires are damaged (the self sealing ooze is coming out of the wires in areas), feeder needs to be replaced | MATTHEW | MATTHEW | | EUG | T | 4797238 |
FOUNTAIN VALLEY ELECTRICAL, LLC | ER | C | 08/12/2014 | | MATTHEW | MATTHEW | | ER | C | 4795307 |
FOUNTAIN VALLEY ELECTRICAL, LLC | ES | L | 08/11/2014 | canceled by contractor | MATTHEW | MATTHEW | | ES | L | 4794453 |
FOUNTAIN VALLEY ELECTRICAL, LLC | EUG | L | 08/11/2014 | canceled by contractor | MATTHEW | MATTHEW | | EUG | L | 4794444 |
FOUNTAIN VALLEY ELECTRICAL, LLC | ER | L | 08/11/2014 | locked 1:20 | MATTHEW | MATTHEW | | ER | L | 4794443 |
FOUNTAIN VALLEY ELECTRICAL, LLC | ER | L | 08/06/2014 | need underground inspection: no equipment ground ran with feeder | MATTHEW | MATTHEW | | ER | L | 4791776 |
FLOW RIGHT PLUMBING HEATING & IRRIGATION, INC. | HE | L | 08/04/2015 | Renewed at 8/4/2015 10:31:03 AM | SABRINA | SABRINA | | HE | L | 5007185 |
ROBBINS HEATING & AIR CONDITIONING, INC. | H= | C | 11/06/2014 | Correction made. | MICHAELS | MICHAELS | | H= | C | 4849848 |
ROBBINS HEATING & AIR CONDITIONING, INC. | H= | R | 11/04/2014 | Tape is not allowed on B vent. Needs to be removed. Seal joints per mfg, see install instructions. 3rd time on this. Trip fee waived. | MARK | MARK | | H= | R | 4848333 |
FLOW RIGHT PLUMBING HEATING & IRRIGATION, INC. | H= | C | 11/03/2014 | Gas final ok. | MARK | MARK | | H= | C | 4846863 |
ROBBINS HEATING & AIR CONDITIONING, INC. | H= | P | 10/29/2014 | Connect and label gas line, remove foil tape from vent connector. | MICHAELS | MICHAELS | | H= | P | 4844513 |
FLOW RIGHT PLUMBING HEATING & IRRIGATION, INC. | HI | C | 08/22/2014 | 10 lb test ok. Shop heater only. | MARK | MARK | | HI | C | 4802454 |
ROBBINS HEATING & AIR CONDITIONING, INC. | HRR | C | 08/11/2014 | Insulation shield has been installed. Note: Garage heater. | MARK | MARK | | HRR | C | 4794427 |
ROBBINS HEATING & AIR CONDITIONING, INC. | HRR | P | 08/04/2014 | Heat shield required around b vent in attic. Rest ok. | JEFFL | JEFFL | | HRR | P | 4789738 |
FLOW RIGHT PLUMBING HEATING & IRRIGATION, INC. | P= | C | 11/03/2014 | | TIM | TIM | | P= | C | 4847199 |
FLOW RIGHT PLUMBING HEATING & IRRIGATION, INC. | PB | C | 08/22/2014 | | GABE | GABE | | PB | C | 4802484 |
FLOW RIGHT PLUMBING HEATING & IRRIGATION, INC. | PTO | C | 08/22/2014 | GARAGE ONLY, PROVIDE ACCESS TO H2O VALVE BY FINAL | GABE | GABE | | PTO | C | 4802478 |