BUILTRITE BUILDERS | B= | C | 10/31/2014 | | BOBF | BOBF | | B= | C | 4846378 |
BUILTRITE BUILDERS | BIN | C | 09/10/2014 | | DALE | DALE | | BIN | C | 4813454 |
BUILTRITE BUILDERS | BLA | C | 09/10/2014 | | DALE | DALE | | BLA | C | 4813452 |
BUILTRITE BUILDERS | BIN | R | 09/08/2014 | insulate under stairs | DALE | DALE | | BIN | R | 4811880 |
BUILTRITE BUILDERS | BFR | C | 09/04/2014 | | BOBF | BOBF | | BFR | C | 4809466 |
BUILTRITE BUILDERS | BFR | T | 09/03/2014 | PAID (REC#1217688): narrow braced wall covered up before inspection / rest ok, truss eng. on file / ok to insulate | DALE | DALE | | BFR | T | 4808829 |
BUILTRITE BUILDERS | BFR | R | 08/29/2014 | narrow wall is not per plan / need letter for repair at C04 / knee bracing 4' oc at gable strong backs / shim trimmers and king studs throughout / 3 - 2x header at basement window / King stud under window header in basement cut short, replace / strap 5 member post under steel beam in basement / remove wood post understair landing / Support strap for stairway landing / no insulation | BOBF | BOBF | | BFR | R | 4807227 |
BUILTRITE BUILDERS | BFR | T | 08/27/2014 | PAID (REC#1216769): T-brace c-04 and truss repair / lap truss laterials / narrow braced wall not nailed per plan / strong back gable ends / block garage door brackets / missing bearing block on f-01 / mts12 on girger at master bath / 3k on front by deck / strap top plates at front window and st12 trimmer at header / 2 tbe6 at girder at front / 3k at dining room / no inspection done for 1st floor / to many items | DALE | DALE | | BFR | T | 4804980 |
BUILTRITE BUILDERS | BSP | P | 07/07/2014 | front porch ok, need post caps installed on deck posts | CHRISM | CHRISM | | BSP | P | 4771533 |
BUILTRITE BUILDERS | BFI | C | 05/15/2014 | R-10 at walkout | CHRISM | CHRISM | | BFI | C | 4739362 |
BUILTRITE BUILDERS | BFD | C | 05/15/2014 | soils on file drain usable isolate and float | CHRISM | CHRISM | | BFD | C | 4739361 |
BUILTRITE BUILDERS | BFN | C | 05/15/2014 | design and eng report on file | CHRISM | CHRISM | | BFN | C | 4739360 |
BUILTRITE BUILDERS | BFT | C | 05/15/2014 | eng report on file | CHRISM | CHRISM | | BFT | C | 4739358 |
POSITIVE ELECTRIC, LLC | E= | C | 10/16/2014 | | CRAIG | CRAIG | | E= | C | 4836169 |
POSITIVE ELECTRIC, LLC | E= | R | 10/15/2014 | correct clothes closet light clearances, gfci all outlets within 6' of wet bar sink, 50 amp outlet on 30 amp breaker in garage, tighten flex connector at well, label boiler disconnect, expose ufer ----------------no a/c----------------- | MATTHEW | MATTHEW | | E= | R | 4835306 |
POSITIVE ELECTRIC, LLC | ES | C | 08/20/2014 | Residential Underground: 200 amp 3/w: new res------ meter is set; need seal | MATTHEW | MATTHEW | | ES | C | 4800773 |
POSITIVE ELECTRIC, LLC | ES | R | 08/14/2014 | caution tape still not installed | MATTHEW | MATTHEW | | ES | R | 4797155 |
POSITIVE ELECTRIC, LLC | ER | C | 08/12/2014 | finished basement, 2-20, #6al in insulation to cooking | MATTHEW | MATTHEW | | ER | C | 4795447 |
POSITIVE ELECTRIC, LLC | ES | R | 08/12/2014 | caution tape not installed | MATTHEW | MATTHEW | | ES | R | 4795439 |
POSITIVE ELECTRIC, LLC | EUG | C | 05/23/2014 | service lateral from pedestal to home | MATTHEW | MATTHEW | | EUG | C | 4745190 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 10/27/2014 | correction made | TED | TED | | H= | C | 4842578 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | P | 10/24/2014 | need dryer make up air, note: finished basement, sealed combustion boiler | TED | TED | | H= | P | 4841598 |
RIDGEVIEW PLUMBING | HWP | P | 08/21/2014 | 1 Section under test. Test is ok. Ok to cover. (Main lvl) | MARK | MARK | | HWP | P | 4801215 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HC | C | 08/13/2014 | RELEASE METER | TED | TED | | HC | C | 4796092 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 08/13/2014 | finished basement, no a/c, hot water heat, sealed combustion boiler, side arm water heater | TED | TED | | HRR | C | 4796086 |
RIDGEVIEW PLUMBING | HI | C | 08/05/2014 | 1 1/4'' boiler, fireplace, range, bbq | TED | TED | | HI | C | 4790511 |
RIDGEVIEW PLUMBING | P= | C | 10/30/2014 | | TIM | TIM | | P= | C | 4845081 |
RIDGEVIEW PLUMBING | P= | R | 10/28/2014 | no hot water, run drain on 9-d need potable water cert | TIM | TIM | | P= | R | 4843494 |
RIDGEVIEW PLUMBING | PTO | C | 08/05/2014 | finished basement | TED | TED | | PTO | C | 4790500 |
HOMEOWNER | PWO | C | 07/09/2014 | PEX SLEEVED THROUGH FOUNDATION | GABE | GABE | | PWO | C | 4773144 |
RIDGEVIEW PLUMBING | PB | C | 05/20/2014 | NOTE : POTABLE WATER CERTIFICATE BY FINAL | GABE | GABE | | PB | C | 4741898 |