MASTER BILT HOMES, INC. | B= | C | 09/17/2014 | All other required Final inspections are complete. (This is a computer generated result) | DALE | DALE | | B= | C | 4817723 |
MASTER BILT HOMES, INC. | B= | P | 09/17/2014 | Additional Inspections Required: External Agency Inspection HD= by HEALTHDEPT is not Completed yet. finished basement, deck in | DALE | DALE | | B= | P | 4817528 |
MASTER BILT HOMES, INC. | BSP | P | 07/21/2014 | deck piers ok | DALE | DALE | | BSP | P | 4780605 |
MASTER BILT HOMES, INC. | BFR | C | 07/16/2014 | | DALE | DALE | | BFR | C | 4777958 |
MASTER BILT HOMES, INC. | BIN | C | 07/16/2014 | | DALE | DALE | | BIN | C | 4777957 |
MASTER BILT HOMES, INC. | BSP | T | 07/09/2014 | PAID (REC#1206135) PLAN SPLICE FEE: $50 by: SHELLEY for Construction: added deck | SHELLEY | SHELLEY | | BSP | T | 4773259 |
MASTER BILT HOMES, INC. | BFR | R | 07/08/2014 | ok to insulate, need eng to check header and trimmers at kitchen window supporting girder, headout TJI cut at toilet | CHRISM | CHRISM | | BFR | R | 4772451 |
MASTER BILT HOMES, INC. | BSP | P | 06/23/2014 | front and rear porch roofs and posts ok | CHRISM | CHRISM | | BSP | P | 4763156 |
MASTER BILT HOMES, INC. | BSP | T | 06/18/2014 | PAID (REC#1201953) PLAN SPLICE FEE: $50 by: MICHAEL for Construction: Revise deck beam | MICHAELA | MICHAELA | | BSP | T | 4760755 |
MASTER BILT HOMES, INC. | BSP | T | 05/28/2014 | PAID (REC#1197407) PLAN SPLICE FEE: $50 by: DALEH for Mechanical: Changes to duct design. | DALEH | DALEH | | BSP | T | 4746998 |
MASTER BILT HOMES, INC. | BSP | T | 05/28/2014 | PAID (REC#1197407) PLAN SPLICE FEE: $50 by: DANM for Construction: Added windows to rear elevations | DANM | DANM | | BSP | T | 4746952 |
MASTER BILT HOMES, INC. | BFI | C | 05/14/2014 | R-10 at walkout walls | CHRISM | CHRISM | | BFI | C | 4738318 |
MASTER BILT HOMES, INC. | BFD | C | 05/14/2014 | soils on file drain usable isolate and float | CHRISM | CHRISM | | BFD | C | 4738313 |
MASTER BILT HOMES, INC. | BFN | C | 05/14/2014 | design and eng report on file | CHRISM | CHRISM | | BFN | C | 4738311 |
MASTER BILT HOMES, INC. | BFT | C | 05/14/2014 | eng report on file | CHRISM | CHRISM | | BFT | C | 4738310 |
FIRST RATE ELECTRICAL SERVICES, INC. | E= | C | 09/05/2014 | 10 amp fuses in disconnect for sewage pump | CRAIG | CRAIG | | E= | C | 4811179 |
FIRST RATE ELECTRICAL SERVICES, INC. | E= | R | 09/04/2014 | 10 amp OCPD required at sewage pump switch per mfg---------------------- 30 amp a/c ok | MATTHEW | MATTHEW | | E= | R | 4810057 |
FIRST RATE ELECTRICAL SERVICES, INC. | ES | C | 07/03/2014 | Residential Overhead: 200 amp 3/w--- new res---- meter is set; need seal | MATTHEW | MATTHEW | | ES | C | 4771168 |
FIRST RATE ELECTRICAL SERVICES, INC. | ER | C | 07/03/2014 | finished basement, 1-15 at service, 80 amp sub-panel ok--------- verify spacing left of basement fireplace--------- | MATTHEW | MATTHEW | | ER | C | 4771167 |
FIRST RATE ELECTRICAL SERVICES, INC. | EUG | C | 07/03/2014 | service lateral from pole to home | MATTHEW | MATTHEW | | EUG | C | 4771160 |
DESIGN SYSTEMS HEATING & AC | H= | C | 09/15/2014 | Louver door added to mech rm. All ok. | MARK | MARK | | H= | C | 4816034 |
DESIGN SYSTEMS HEATING & AC | H= | P | 09/08/2014 | High/low transfer grills needed to mech room or louver door to verify combustion air. Rest ok. Notes-- AC complete. | JEFFL | JEFFL | | H= | P | 4811678 |
DESIGN SYSTEMS HEATING & AC | HC | C | 07/07/2014 | RELEASE METER | MARK | MARK | | HC | C | 4771602 |
DESIGN SYSTEMS HEATING & AC | HRR | C | 07/07/2014 | All work is completed. Need to secure and seal vent pipe at furnace by final. Rough and DD ok. Note: Need to check for c/a at final, need to check for vent pipe on furnace secured and sealed at furnace.. Has a/c rough OSA to ret. F.Bsmnt. | MARK | MARK | | HRR | C | 4771598 |
DESIGN SYSTEMS HEATING & AC | HRR | P | 07/03/2014 | Heat run missing to kitchen (Toe-kick) Clearance issue with pex and w/h vent connector. 6" min required with single wall pipe. Not ready in mech rm. Need to check vent pipe for furnace and c/a. a/c coil. Rest ok. | MARK | MARK | | HRR | P | 4770841 |
DOUBLE J GAS, INC. | HI | C | 07/01/2014 | 10 lb test ok. Note: Furn, w/h, f/p, future bbq, rng. on 1 1/4" main | MARK | MARK | | HI | C | 4769149 |
JOLLY PLUMBING & HEATING INC. | P= | C | 09/15/2014 | | TIM | TIM | | P= | C | 4816028 |
JOLLY PLUMBING & HEATING INC. | P= | P | 08/28/2014 | NO ABLE TO TEST MASTER SHOWER , SECURE HOSE BIB . NEED POTABLE WATER CERT FOR COMPLETION , NOTE : FINISHED BASEMENT . PVB INSTALLED | GABE | GABE | | P= | P | 4806177 |
JOLLY PLUMBING & HEATING INC. | PTO | C | 07/01/2014 | DWV SLEEVED THROUGH FOUNDATION . NOTE : POTABLE WATER CERT BY FINAL | GABE | GABE | | PTO | C | 4768891 |
JOLLY PLUMBING & HEATING INC. | PWO | C | 07/01/2014 | PEX SLEEVED AT FOUNDATION | GABE | GABE | | PWO | C | 4768881 |
JOLLY PLUMBING & HEATING INC. | PTO | P | 06/24/2014 | NOTE : FINISHED BASEMENT . NO IRRIGATION . NEED TO SEE DWV TIE IN AND PIPE SLEEVED THROUGH FOUNDATION . NEED TO TEST THROUGH TUB TRAP . REST OK | GABE | GABE | | PTO | P | 4764195 |
JOLLY PLUMBING & HEATING INC. | PB | C | 05/22/2014 | basement drains to sewage ejector, note: drains on 1st floor need to gravity drain out | TED | TED | | PB | C | 4744049 |