HOFFMAN HOMES INC | B= | C | 12/17/2014 | finished basement, deck in | DALE | DALE | | B= | C | 4873280 |
HOFFMAN HOMES INC | B= | R | 12/15/2014 | Additional Inspections Required. need fireplace hearth 18" min. | DALE | DALE | | B= | R | 4871609 |
HOFFMAN HOMES INC | B= | R | 12/15/2014 | Additional Inspections Required: External Agency Inspection HD= by HEALTHDEPT is not Completed yet (This is a computer generated result) | SYSTEM | SYSTEM | | B= | R | 4871610 |
HOFFMAN HOMES INC | B= | R | 12/12/2014 | Additional Inspections Required. need instruction book for fireplace / need smoke detector at hall and c/o / nail deck straps | DALE | DALE | | B= | R | 4870910 |
HOFFMAN HOMES INC | B= | R | 12/12/2014 | Additional Inspections Required: External Agency Inspection HD= by HEALTHDEPT is not Completed yet (This is a computer generated result) | SYSTEM | SYSTEM | | B= | R | 4870911 |
HOFFMAN HOMES INC | BLA | C | 09/08/2014 | | DALE | DALE | | BLA | C | 4811879 |
HOFFMAN HOMES INC | BFR | C | 08/18/2014 | | DALE | DALE | | BFR | C | 4798780 |
HOFFMAN HOMES INC | BIN | C | 08/18/2014 | | DALE | DALE | | BIN | C | 4798775 |
HOFFMAN HOMES INC | BFR | R | 08/05/2014 | foam and firestop / missing hangers under stair landings / strap all studs at stair landing / furr out wall behind dryer box / ok to insulate | DALE | DALE | | BFR | R | 4790615 |
HOFFMAN HOMES INC | BSP | T | 08/04/2014 | PAID (REC#1211571) PLAN SPLICE FEE: $50 by: MICHAEL for Construction: added windows | MICHAELA | MICHAELA | | BSP | T | 4789795 |
HOFFMAN HOMES INC | BSP | P | 07/07/2014 | porch roof and posts ok | CHRISM | CHRISM | | BSP | P | 4771516 |
HOFFMAN HOMES INC | BSP | P | 06/03/2014 | deck piers ok | DALE | DALE | | BSP | P | 4750050 |
HOFFMAN HOMES INC | BFD | C | 05/08/2014 | soils on file drain usable isolate and float | CHRISM | CHRISM | | BFD | C | 4735125 |
HOFFMAN HOMES INC | BFI | C | 05/08/2014 | R-10 at walkout | CHRISM | CHRISM | | BFI | C | 4735122 |
HOFFMAN HOMES INC | BFN | C | 05/08/2014 | design and eng report on file | CHRISM | CHRISM | | BFN | C | 4735117 |
HOFFMAN HOMES INC | BFT | C | 05/08/2014 | eng report on file | CHRISM | CHRISM | | BFT | C | 4735113 |
HOFFMAN HOMES INC | BFN | P | 04/30/2014 | AUTHORIZED INSPECTION BY ENGINEER | BPHILLIPS | BPHILLIPS | BPHILLIPS | BFN | P | 4730372 |
HOFFMAN HOMES INC | BFT | P | 04/30/2014 | AUTHORIZED INSPECTION BY ENGINEER | BPHILLIPS | BPHILLIPS | BPHILLIPS | BFT | P | 4730371 |
LONGHORN ELECTRIC, INC. | E= | C | 11/25/2014 | a/c ok 50 amp | CRAIG | CRAIG | | E= | C | 4859947 |
LONGHORN ELECTRIC, INC. | ER | C | 07/31/2014 | | MATTHEW | MATTHEW | | ER | C | 4787966 |
LONGHORN ELECTRIC, INC. | ER | R | 07/28/2014 | finish all framing; check at wet bar, need fireplace installed, add outlet at living room hand rail -------verify spacing between kitchen countertop and exterior door-------------------- finished basement, 6-3 nm ran to cooking, 60 amp sub-panel ok (not breakered), no mcc's | MATTHEW | MATTHEW | | ER | R | 4785473 |
LONGHORN ELECTRIC, INC. | EUG | C | 07/28/2014 | service lateral from pole to home | MATTHEW | MATTHEW | | EUG | C | 4785472 |
LONGHORN ELECTRIC, INC. | ES | C | 07/28/2014 | Residential Overhead: 200 amp 3/w: new res---- meter is set; need seal | MATTHEW | MATTHEW | | ES | C | 4785467 |
FALCON HEATING AND COOLING, INC. | H= | C | 12/11/2014 | All corrections have been completed. Ok. | MARK | MARK | | H= | C | 4869559 |
FALCON HEATING AND COOLING, INC. | H= | P | 12/08/2014 | COMPLETE WH FLUE TERMINATIONS - COMPLETE INSULATION ON CONDENSER - REST OK. NOTES: DIRECT VENT FURN / WH - PARTIAL FINISHED CONDITIONED BASEMENT - FULL AC | JERRYF | JERRYF | | H= | P | 4867482 |
L & L GAS SHOP, LLC. | HO | C | 10/16/2014 | 10lb test on 1 1/4'' p.e. from meter at garage under ground to rear of house connected to house piping | TED | TED | | HO | C | 4836056 |
FALCON HEATING AND COOLING, INC. | HC | C | 08/04/2014 | RELEASE METER | MARK | MARK | | HC | C | 4789318 |
FALCON HEATING AND COOLING, INC. | HRR | C | 08/04/2014 | Repairs have been completed. Ok. | MARK | MARK | | HRR | C | 4789311 |
L & L GAS SHOP, LLC. | HI | C | 07/16/2014 | correction made | TED | TED | | HI | C | 4777882 |
FALCON HEATING AND COOLING, INC. | HRR | R | 07/16/2014 | need 2nd bath fan and vent for basement bathroom over tub area, seal returns in basement ceiling, note: partial basement finish, a/c rough, duct design | TED | TED | | HRR | R | 4777879 |
L & L GAS SHOP, LLC. | HI | R | 07/15/2014 | low test, note: 1 1/4'' furnace, w/h, dryer, range, upper and lower deck outlets, garage outlet | TED | TED | | HI | R | 4777135 |
B & L PLUMBING, INC. | P= | C | 12/11/2014 | NOTE : FINISHED BASEMENT , PVB INSTALLED , NEED PIX OF HI LOOPS SECURE , AND TRAP INSTALLED . POTABLE WATER CERT TO SCANNING | GABE | GABE | | P= | C | 4869778 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PWO | C | 08/04/2014 | need certificate of potable water by final | TED | TED | | PWO | C | 4789671 |
B & L PLUMBING, INC. | PTO | C | 07/17/2014 | finished basement | TED | TED | | PTO | C | 4778854 |
B & L PLUMBING, INC. | PTO | T | 07/03/2014 | PAID (REC#1207574): NOT READY | GABE | GABE | | PTO | T | 4771118 |
B & L PLUMBING, INC. | PB | C | 05/16/2014 | POTABLE WATER CERTIFICATE BY FINAL | GABE | GABE | | PB | C | 4740019 |