LAURIA BUILDERS & LAND, LLC. | B= | C | 10/16/2014 | All other required Final inspections are complete. (This is a computer generated result) | DALE | DALE | | B= | C | 4835603 |
LAURIA BUILDERS & LAND, LLC. | B= | P | 10/02/2014 | Additional Inspections Required: External Agency Inspection HD= by HEALTHDEPT is not Completed yet, Plumbing Final Inspection is not Completed yet. finished basement, deck in | DALE | DALE | | B= | P | 4827346 |
LAURIA BUILDERS & LAND, LLC. | BLA | C | 08/01/2014 | | DALE | DALE | | BLA | C | 4788937 |
LAURIA BUILDERS & LAND, LLC. | BIN | C | 07/18/2014 | | DALE | DALE | | BIN | C | 4779455 |
LAURIA BUILDERS & LAND, LLC. | BSP | P | 07/18/2014 | lower level porch ok | DALE | DALE | | BSP | P | 4779444 |
LAURIA BUILDERS & LAND, LLC. | BFR | C | 07/17/2014 | | DALE | DALE | | BFR | C | 4778600 |
LAURIA BUILDERS & LAND, LLC. | BIN | R | 07/17/2014 | need air barrier at both fireplaces | DALE | DALE | | BIN | R | 4778590 |
LAURIA BUILDERS & LAND, LLC. | BFR | R | 07/15/2014 | missing gusset on b-6 / need headroom at stairs / furr down garage ceiling at return / ok to insulate | DALE | DALE | | BFR | R | 4777225 |
LAURIA BUILDERS & LAND, LLC. | BSP | P | 06/23/2014 | front and rear porch roofs and posts ok | CHRISM | CHRISM | | BSP | P | 4763280 |
LAURIA BUILDERS & LAND, LLC. | BFI | C | 05/27/2014 | R-10 at walkout | CHRISM | CHRISM | | BFI | C | 4745592 |
LAURIA BUILDERS & LAND, LLC. | BFD | C | 05/27/2014 | soils and open hole on file drain usable isolate and float | CHRISM | CHRISM | | BFD | C | 4745591 |
LAURIA BUILDERS & LAND, LLC. | BFN | C | 05/27/2014 | eng report on file | CHRISM | CHRISM | | BFN | C | 4745587 |
LAURIA BUILDERS & LAND, LLC. | BFT | C | 05/27/2014 | eng report on file | CHRISM | CHRISM | | BFT | C | 4745581 |
LAURIA BUILDERS & LAND, LLC. | BFN | P | 05/02/2014 | AUTHORIZED INSPECTION BY ENGINEER | MINDY | MINDY | MINDY | BFN | P | 4731867 |
LAURIA BUILDERS & LAND, LLC. | BFT | P | 05/02/2014 | AUTHORIZED INSPECTION BY ENGINEER | MINDY | MINDY | MINDY | BFT | P | 4731866 |
LONGHORN ELECTRIC, INC. | E= | C | 09/30/2014 | | MATTHEW | MATTHEW | | E= | C | 4825734 |
LONGHORN ELECTRIC, INC. | E= | R | 09/26/2014 | need access to spa motor, deck in-use cover upside down, strap flex and install ko seal at well controls, unlock room in mech room----------- no a/c | MATTHEW | MATTHEW | | E= | R | 4823916 |
LONGHORN ELECTRIC, INC. | EP | C | 07/11/2014 | Sub panel feeders wired correctly | JOSEPH | JOSEPH | | EP | C | 4775662 |
LONGHORN ELECTRIC, INC. | ES | C | 07/11/2014 | Residential Underground: 200 amp 3w new res meter in need to reseal | JOSEPH | JOSEPH | | ES | C | 4775656 |
LONGHORN ELECTRIC, INC. | EUG | C | 07/11/2014 | | JOSEPH | JOSEPH | | EUG | C | 4775655 |
LONGHORN ELECTRIC, INC. | ER | C | 07/11/2014 | | JOSEPH | JOSEPH | | ER | C | 4775651 |
LONGHORN ELECTRIC, INC. | ER | R | 07/09/2014 | well wire not installed ------------ 2 - # 6 CU , 3 - # 10 CU finished basement , wired for whirlpool tub ( not set ) | TOMC | TOMC | | ER | R | 4773774 |
ARROW HAWK HEATING, LLC | H= | C | 09/29/2014 | 6 IN OSA NO AC . | GABE | GABE | | H= | C | 4824856 |
MJB PLUMBING AND HEATING, INC | HC | C | 07/14/2014 | RELEASE METER | JEFFL | JEFFL | | HC | C | 4776085 |
MJB PLUMBING AND HEATING, INC | HI | C | 07/14/2014 | 10 LB. test ok. Notes-- 1 1/4'' main.. 1 furnace.. 2 wh.. 2 fp.. 1 range.. 1 bbq. | JEFFL | JEFFL | | HI | C | 4776076 |
ARROW HAWK HEATING, LLC | HRR | C | 07/14/2014 | Correction made. | JEFFL | JEFFL | | HRR | C | 4776073 |
ARROW HAWK HEATING, LLC | HRR | P | 07/11/2014 | Framing not complete around b vent. Rest ok. Notes-- Finished basement. AC rough. OSA to return. Direct vent furnace.. Equipment cert to scanning. | JEFFL | JEFFL | | HRR | P | 4775162 |
MJB PLUMBING AND HEATING, INC | P= | C | 10/16/2014 | received potable water cert | TIM | TIM | | P= | C | 4835602 |
MJB PLUMBING AND HEATING, INC | P= | P | 09/26/2014 | PENDING POTABLE WATER CERT , NOTE : FINISHED BASEMENT . RP IN MEC ROOM | GABE | GABE | | P= | P | 4823606 |
MJB PLUMBING AND HEATING, INC | PWO | C | 07/11/2014 | NOTE : FINISHED BASEMENT . RP IN MEC ROOM , POTABLE WATER CERT BY FINAL | GABE | GABE | | PWO | C | 4775245 |
MJB PLUMBING AND HEATING, INC | PTO | C | 07/11/2014 | | GABE | GABE | | PTO | C | 4775239 |
MJB PLUMBING AND HEATING, INC | PB | C | 06/02/2014 | DWV ONLY | GABE | GABE | | PB | C | 4749082 |