GOEBEL CONSTRUCTION, INC | B= | C | 11/03/2014 | All other required Final inspections are complete. (This is a computer generated result) | BOBF | BOBF | | B= | C | 4846678 |
GOEBEL CONSTRUCTION, INC | B= | P | 10/31/2014 | Additional Inspections Required: External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | BOBF | BOBF | | B= | P | 4846265 |
GOEBEL CONSTRUCTION, INC | BFR | C | 07/23/2014 | | DALE | DALE | | BFR | C | 4782731 |
GOEBEL CONSTRUCTION, INC | BIN | C | 07/23/2014 | | DALE | DALE | | BIN | C | 4782723 |
GOEBEL CONSTRUCTION, INC | BFR | T | 07/18/2014 | PAID (REC#1208882) correction not made | DALE | DALE | | BFR | T | 4779489 |
GOEBEL CONSTRUCTION, INC | BFR | R | 07/17/2014 | 2 2BE6 at master / ok to insulate | DALE | DALE | | BFR | R | 4778812 |
GOEBEL CONSTRUCTION, INC | BSP | P | 06/30/2014 | front and rear porch roofs and columns ok | CHRISM | CHRISM | | BSP | P | 4768007 |
GOEBEL CONSTRUCTION, INC | BSP | P | 06/02/2014 | pier for rear porch roof ok | CHRISM | CHRISM | | BSP | P | 4749400 |
GOEBEL CONSTRUCTION, INC | BFI | C | 05/27/2014 | R-10 at walkout | CHRISM | CHRISM | | BFI | C | 4745792 |
GOEBEL CONSTRUCTION, INC | BFD | C | 05/27/2014 | soils on file drain usable isolate and float | CHRISM | CHRISM | | BFD | C | 4745791 |
GOEBEL CONSTRUCTION, INC | BFN | P | 05/27/2014 | eng report on file, need copy of foundation design for file | CHRISM | CHRISM | | BFN | P | 4745790 |
GOEBEL CONSTRUCTION, INC | BFT | C | 05/27/2014 | eng report on file | CHRISM | CHRISM | | BFT | C | 4745784 |
GOEBEL CONSTRUCTION, INC | BFN | P | 05/16/2014 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFN | P | 4739935 |
GOEBEL CONSTRUCTION, INC | BFT | P | 05/16/2014 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFT | P | 4739934 |
HIGH MOUNTAIN ELECTRIC INC. | E= | C | 10/30/2014 | CORRECTIONS MADE----------------------30 AMP AC OK | BRIAN | BRIAN | | E= | C | 4845338 |
HIGH MOUNTAIN ELECTRIC INC. | E= | R | 10/29/2014 | complete re-inspect------- inspected exterior, garage and part of unfinished basement only: partial list: need boxes behind exterior lights (leave all exterior lights down for final), missing handle tie, provide means to check upper outlet on back deck, outlet on basement fixtures need to be gfci protected, ko seal at a/c disconnect--------------- complete re-inspect | MATTHEW | MATTHEW | | E= | R | 4844743 |
HIGH MOUNTAIN ELECTRIC INC. | E= | L | 10/27/2014 | canceled by contractor | MATTHEW | MATTHEW | | E= | L | 4842431 |
SANCHEZ ELECTRIC, INC. | EUG | C | 07/18/2014 | 4/0 urd ok | TOMC | TOMC | | EUG | C | 4779843 |
SANCHEZ ELECTRIC, INC. | ES | C | 07/18/2014 | Residential Underground: 200 amp ok to seal --------1 - # 6 CU , 1 - # 8 CU , 1 - # 10 CU , 2 - 15 amp MCC | TOMC | TOMC | | ES | C | 4779837 |
SANCHEZ ELECTRIC, INC. | ER | C | 07/16/2014 | unfinished basement------ check mcc's at time of service inspection | MATTHEW | MATTHEW | | ER | C | 4778326 |
HOMEOWNER | ER | R | 07/09/2014 | make up grounds at entry outlet, need dedicated circuit for hood (on small appliance circuit now), seal return air where nm runs thru it, correct spacing in front bedroom by pocket door, staple nm in master bedroom, install light for exterior basement door, ground metal extension ring in basement, nm hanging in basement, can't run 14-2 on bottom of floor joist in basement, install future basement circuits to basement------------ call with questions 327-2952----------- complete re-inspect | MATTHEW | MATTHEW | | ER | R | 4773599 |
MICK HEATING & SHEET METAL CO. | H= | C | 10/29/2014 | unfinished basement, a/c installed | TED | TED | | H= | C | 4844266 |
MICK HEATING & SHEET METAL CO. | HC | C | 07/10/2014 | RELEASE METER | TED | TED | | HC | C | 4774411 |
MICK HEATING & SHEET METAL CO. | HRR | C | 07/10/2014 | by final support furnace venting in basement ceiling, note: unfinished basement, a/c rough, no outside air to return, duct design | TED | TED | | HRR | C | 4774408 |
AMERICAN PRIDE PLUMBING | HI | C | 07/01/2014 | 10lb test ok. Note: Furn, w/h, c/t, bbq, future f/p. | MARK | MARK | | HI | C | 4769130 |
AMERICAN PRIDE PLUMBING | P= | C | 10/29/2014 | unfinished basement, no sprinkler stub, certificate of potable water to scanning | TED | TED | | P= | C | 4844268 |
AMERICAN PRIDE PLUMBING | PTO | C | 07/01/2014 | NOTE : UNFINISHED BASEMENT . WATER LINES RUN FOR FUTURE BASEMENT FIXTURES . NO IRRIGATION . DRAIN DOWN FOR GARAGE SINK AT MANIFOLD . | GABE | GABE | | PTO | C | 4768868 |
AMERICAN PRIDE PLUMBING | PWO | C | 06/02/2014 | H2O SLEEVED THROUGH FOUNDATION . | GABE | GABE | | PWO | C | 4749051 |
AMERICAN PRIDE PLUMBING | PB | C | 06/02/2014 | | GABE | GABE | | PB | C | 4749045 |