ELEVATION HOMES, LLC | B= | C | 12/03/2014 | finished basement, deck in | DALE | DALE | | B= | C | 4863735 | ELEVATION HOMES, LLC | BFR | C | 09/24/2014 | eng. on file for post | DALE | DALE | | BFR | C | 4821911 | ELEVATION HOMES, LLC | BIN | P | 09/23/2014 | complete bfr | DALE | DALE | | BIN | P | 4821129 | ELEVATION HOMES, LLC | BIN | R | 09/22/2014 | not complete | DALE | DALE | | BIN | R | 4820342 | ELEVATION HOMES, LLC | BFR | R | 09/19/2014 | still need eng. for posts under by at basement corner / eng. on file for beam at mech. room | DALE | DALE | | BFR | R | 4819762 | ELEVATION HOMES, LLC | BLA | C | 09/19/2014 | | DALE | DALE | | BLA | C | 4819761 | ELEVATION HOMES, LLC | BLA | R | 09/18/2014 | lath on front of garage not complete / narrow braced wall ok | DALE | DALE | | BLA | R | 4818881 | ELEVATION HOMES, LLC | BFR | R | 09/17/2014 | 3 2x6 under girder at basement / need eng. for post under steel beam at basement and at mech. room / narrow braced wall not nailed per plan / ok to insulate | DALE | DALE | | BFR | R | 4817804 | ELEVATION HOMES, LLC | BLA | R | 09/17/2014 | canceled by contractor | DALE | DALE | | BLA | R | 4817810 | ELEVATION HOMES, LLC | BSP | T | 09/11/2014 | PAID (REC#1220258) PLAN SPLICE FEE: $50 by: DALEH for Mechanical | DALEH | DALEH | | BSP | T | 4814386 | ELEVATION HOMES, LLC | BSP | P | 08/28/2014 | front porch and posts okay / rear deckframing with posts okay | BOBF | BOBF | | BSP | P | 4806415 | ELEVATION HOMES, LLC | BFI | C | 06/30/2014 | R-10 at walkout | CHRISM | CHRISM | | BFI | C | 4768041 | ELEVATION HOMES, LLC | BFD | C | 06/30/2014 | soils on file drain usable isolate and float | CHRISM | CHRISM | | BFD | C | 4768039 | ELEVATION HOMES, LLC | BFN | C | 06/30/2014 | design and eng report on file | CHRISM | CHRISM | | BFN | C | 4768037 | ELEVATION HOMES, LLC | BFT | C | 06/30/2014 | eng report on file | CHRISM | CHRISM | | BFT | C | 4768035 | ELEVATION HOMES, LLC | BFN | P | 05/14/2014 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFN | P | 4738317 | ELEVATION HOMES, LLC | BFT | P | 05/14/2014 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFT | P | 4738316 | POSITIVE ELECTRIC, LLC | E= | C | 11/26/2014 | | CRAIG | CRAIG | | E= | C | 4861615 | POSITIVE ELECTRIC, LLC | ES | C | 11/26/2014 | Residential Underground: 200 amp 3/w new res. seal meter | CRAIG | CRAIG | | ES | C | 4861612 | POSITIVE ELECTRIC, LLC | E= | R | 11/14/2014 | neutrals need to originate from same panel board as phase conductors, conduit for sub-panel under sized, mud room in basement has outlet on bath circuit------------------------ caution tape has never been installed over service conductors; call me in the am 327-2952---------------------- a/c pre-wire--------------- future generator set up----------------- | MATTHEW | MATTHEW | | E= | R | 4854296 | POSITIVE ELECTRIC, LLC | ES | R | 11/14/2014 | Residential Underground: expose caution tape full length of service run | TOMC | TOMC | | ES | R | 4854280 | POSITIVE ELECTRIC, LLC | ES | R | 09/11/2014 | need caution tape installed entire length | MATTHEW | MATTHEW | | ES | R | 4814512 | POSITIVE ELECTRIC, LLC | ER | C | 09/10/2014 | | MATTHEW | MATTHEW | | ER | C | 4813565 | POSITIVE ELECTRIC, LLC | ES | R | 09/08/2014 | expose caution tape | MATTHEW | MATTHEW | | ES | R | 4811473 | POSITIVE ELECTRIC, LLC | ER | R | 09/08/2014 | need wire form well to controller installed, seal return air, return air to theater room blocked off? is it staying that way?, finish framing around can lights at basement fireplace, ground and secure basement safe switch, is basement guest bath getting an ex-fan; duct ran?----------- finished basement, 8-3nm and 10-3 nm ran for cooking equipment, 4-3nm stubbed out and 8-2nm ran for a/c | MATTHEW | MATTHEW | | ER | R | 4811470 | POSITIVE ELECTRIC, LLC | EUG | C | 07/18/2014 | 4/0 urd ok | TOMC | TOMC | | EUG | C | 4779858 | BRUNO'S HEATING & COOLING | H= | C | 11/20/2014 | correction made | TED | TED | | H= | C | 4857242 | BRUNO'S HEATING & COOLING | H= | P | 11/19/2014 | Need to complete furn vent termination. Rest ok. Note: Fin. Bsmnt, DV furn Hi/Lo grills. No a/c condenser at final. | MARK | MARK | | H= | P | 4856235 | BRUNO'S HEATING & COOLING | HC | C | 09/12/2014 | RELEASE METER | TED | TED | | HC | C | 4814877 | BRUNO'S HEATING & COOLING | HRR | C | 09/12/2014 | correction made | TED | TED | | HRR | C | 4814869 | BRUNO'S HEATING & COOLING | HRR | R | 09/10/2014 | roof paper on b vent, seal returns, missing 2 supplys in unfinished storage room, note: finished basement, a/c rough, outside air to return, duct design | TED | TED | | HRR | R | 4813054 | BRUNO'S HEATING & COOLING | HRR | R | 09/09/2014 | cancel per e mail | TED | TED | | HRR | R | 4812133 | DOUBLE J GAS, INC. | HI | C | 08/22/2014 | 10 lb test ok. Note: 1 1/4" main. Gas stub for future fire pit/ BBQ?, Furn (Not present), w/h, c/t, f/p | MARK | MARK | | HI | C | 4802458 | PACIFIC PLUMBING, INCORPORATED | P= | C | 11/26/2014 | no sprinkler stub | TIM | TIM | | P= | C | 4861189 | PACIFIC PLUMBING, INCORPORATED | PTO | C | 08/29/2014 | valve for pot filler in mech room | TIM | TIM | | PTO | C | 4807217 | PACIFIC PLUMBING, INCORPORATED | PTO | P | 08/28/2014 | NO TEST ON HOT SIDE WATER , NEED VALVE FOR POT FILLER , SLEEVE DWV THROUGH FOUNDATION 2X PIPE SIZE . REST OK | GABE | GABE | | PTO | P | 4806146 | HOMEOWNER | PWO | C | 08/25/2014 | need certificate of potable water by final | TED | TED | | PWO | C | 4803359 | PACIFIC PLUMBING, INCORPORATED | PB | C | 07/08/2014 | LOWER LEVEL DWV TO PUMP ONLY . NOTE : POTABLE WATER CERT BY FINAL | GABE | GABE | | PB | C | 4772421 |
|
|