CAMPBELL HOMES LTD. | B= | C | 09/22/2014 | finished basement, no deck | ED | ED | | B= | C | 4820534 |
CAMPBELL HOMES LTD. | BLA | C | 07/29/2014 | | ED | ED | | BLA | C | 4786258 |
CAMPBELL HOMES LTD. | BIN | C | 07/24/2014 | | DALE | DALE | | BIN | C | 4783320 |
CAMPBELL HOMES LTD. | BFR | C | 07/24/2014 | | DALE | DALE | | BFR | C | 4783315 |
CAMPBELL HOMES LTD. | BFR | R | 07/22/2014 | nail off CS 16-32 @BGA2 / Missing steel bearing plate between BGA2 and 6 member post / Strap 6 member post / monopost in basement below 6 member post needs to be turned 90 degrees for full bearing / BG1 missing 2 TBE4, 1 LTS 16 and 24" bearing block next to entry | BOBF | BOBF | | BFR | R | 4781738 |
CAMPBELL HOMES LTD. | BSP | P | 07/14/2014 | rear porch lid and post connections ok, front porch was inspected prior and ok | ED | ED | | BSP | P | 4776015 |
CAMPBELL HOMES LTD. | BSP | P | 07/11/2014 | front porch lid and post connection (only) ok | ED | ED | | BSP | P | 4775387 |
CAMPBELL HOMES LTD. | BFD | C | 06/19/2014 | all paperwork on file / float / ufer in per eng. | DALE | DALE | | BFD | C | 4761365 |
CAMPBELL HOMES LTD. | BFN | C | 06/19/2014 | ok per eng. | DALE | DALE | | BFN | C | 4761364 |
CAMPBELL HOMES LTD. | BFT | C | 06/19/2014 | ok per eng. | DALE | DALE | | BFT | C | 4761360 |
CAMPBELL HOMES LTD. | BSP | P | 05/23/2014 | Adding patio cover | DANM | DANM | | BSP | P | 4744515 |
CAMPBELL HOMES LTD. | BFN | P | 05/15/2014 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFN | P | 4739105 |
CAMPBELL HOMES LTD. | BFT | P | 05/15/2014 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFT | P | 4739104 |
POSITIVE ELECTRIC, LLC | E= | C | 09/16/2014 | 30 amp breaker for ac unit | JOSEPH | JOSEPH | | E= | C | 4816968 |
POSITIVE ELECTRIC, LLC | E= | R | 09/15/2014 | ac breaker too large 35 amp max ----------------- wet bar pre roughed | JOSEPH | JOSEPH | | E= | R | 4816123 |
POSITIVE ELECTRIC, LLC | E= | R | 09/12/2014 | not ready | MATTHEW | MATTHEW | | E= | R | 4815130 |
POSITIVE ELECTRIC, LLC | ES | C | 07/21/2014 | Residential Underground: 150 amp 3w new res meter in need to reseal | JOSEPH | JOSEPH | | ES | C | 4780724 |
POSITIVE ELECTRIC, LLC | ER | C | 07/21/2014 | finished basement----------------------- 2 - 6/3 al 1 - 20 | JOSEPH | JOSEPH | | ER | C | 4780721 |
POSITIVE ELECTRIC, LLC | EUG | C | 07/01/2014 | | JOSEPH | JOSEPH | | EUG | C | 4769423 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 09/19/2014 | high low t- grills ac complete | TIM | TIM | | H= | C | 4819798 |
DOUBLE J GAS, INC. | HI | C | 07/18/2014 | 11/4 furnace water heater 2-fireplaces bbq range dryer | TIM | TIM | | HI | C | 4780080 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HC | C | 07/18/2014 | RELEASE METER | TIM | TIM | | HC | C | 4780079 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 07/18/2014 | by final need equipment schedule | TIM | TIM | | HRR | C | 4780078 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | P | 07/16/2014 | frame basement fireplace, drop s/a below soffit, support s/a ducts in baseemnt several places resting on walls, need equipment schedule....rest ok finished basement osa to r/a a/c prep | TIM | TIM | | HRR | P | 4778057 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | P | 07/15/2014 | cancel per Troy | TIM | TIM | | HRR | P | 4777134 |
SPRINGS CUSTOM PLUMBING, INC. | P= | C | 09/15/2014 | pvb installed | TIM | TIM | | P= | C | 4816074 |
SPRINGS CUSTOM PLUMBING, INC. | PTO | C | 07/16/2014 | | TIM | TIM | | PTO | C | 4778059 |
SPRINGS CUSTOM PLUMBING, INC. | PB | C | 06/25/2014 | | TIM | TIM | | PB | C | 4765547 |