HOMEOWNER | B= | C | 08/14/2017 | Correction made | JUSTINL | JUSTINL | | B= | C | 5595431 |
HOMEOWNER | B= | P | 08/09/2017 | Guard needed at stairs to upper floor for fall greater than 30" // Crawl space -- Schedule a new Building Final when above items are complete. | JUSTINL | JUSTINL | | B= | P | 5590163 |
HOMEOWNER | BSP | T | 07/18/2017 | PAID (REC#1439945) PLAN SPLICE FEE: $50 by: MICHAELA for Construction: As built | MICHAELA | MICHAELA | | BSP | T | 5567893 |
HOMEOWNER | BFR | C | 01/25/2016 | | DALE | DALE | | BFR | C | 5122596 |
HOMEOWNER | BIN | C | 01/25/2016 | | DALE | DALE | | BIN | C | 5122578 |
HOMEOWNER | BIN | P | 08/06/2015 | complete stairs at garage for bfr / insulation ok | DALE | DALE | | BIN | P | 5009202 |
HOMEOWNER | BIN | R | 08/04/2015 | insulate rim, behind boxes and garage wall | DALE | DALE | | BIN | R | 5007501 |
HOMEOWNER | BFR | R | 07/24/2015 | need truss calcs / foam and firestop / garage stairs rise can vary over 3/8" / ok to insulate | DALE | DALE | | BFR | R | 5000434 |
HOMEOWNER | BFR | P | 07/10/2015 | deck floor ok | DALE | DALE | | BFR | P | 4990869 |
HOMEOWNER | BLA | C | 11/26/2014 | | DALE | DALE | | BLA | C | 4861243 |
HOMEOWNER | BSP | P | 11/20/2014 | wets porch ok, rear lid ok, no post | DALE | DALE | | BSP | P | 4857411 |
HOMEOWNER | BFD | C | 07/10/2014 | drain crawl space | CHRISM | CHRISM | | BFD | C | 4774256 |
HOMEOWNER | BFN | C | 06/26/2014 | need complete soils at drain | CHRISM | CHRISM | | BFN | C | 4766339 |
HOMEOWNER | BFT | C | 06/23/2014 | open hole on file | CHRISM | CHRISM | | BFT | C | 4762863 |
HOMEOWNER | BFT | R | 06/20/2014 | need open hole inspection on site | ED | ED | | BFT | R | 4762756 |
HOMEOWNER | E= | C | 07/19/2017 | | MATTHEW | MATTHEW | | E= | C | 5568857 |
HOMEOWNER | ES | C | 07/19/2017 | Residential Overhead: 200 amp 3/w: new res------ no action needed; meter set and sealed by MTVE | MATTHEW | MATTHEW | | ES | C | 5568847 |
HOMEOWNER | ES | R | 07/14/2017 | remove temp | MATTHEW | MATTHEW | | ES | R | 5564301 |
HOMEOWNER | E= | R | 07/14/2017 | need tr outlet between OH doors inside garage, nm pinched between cover and wall to get to wiremold behind fridge, need 2 screws for industrial cover at water heater | MATTHEW | MATTHEW | | E= | R | 5564289 |
HOMEOWNER | ES | R | 03/07/2017 | remove temp | MATTHEW | MATTHEW | | ES | R | 5433830 |
HOMEOWNER | E= | R | 03/07/2017 | no power to front exterior outlets and outlet between OH doors, outlet between OH doors needs to be tr, gfci outlet right of range, correct spacing left of fridge, attach light at water heater, need 2 screws for outlet at water heater, no power to dryer ex booster, cage crawler lights, correct coat closet light clearance and bedroom closet light clearance, need tr outlet in upper bedroom, gfci all bathroom outlets, open ground in sun room double duplex under window--------------- no a/c | MATTHEW | MATTHEW | | E= | R | 5433829 |
HOMEOWNER | E16 | C | 06/24/2016 | Gave homeowner a consultation on how to complete electrical final. | JOSEPH | JOSEPH | | E16 | C | 5231185 |
HOMEOWNER | E= | T | 06/22/2016 | PAID (REC#1337032) | DEAN | DEAN | | E= | T | 5228250 |
HOMEOWNER | ER | C | 06/19/2015 | | CRAIG | CRAIG | | ER | C | 4977300 |
HOMEOWNER | EUG | P | 06/17/2015 | service lateral to house pot hole ok | CRAIG | CRAIG | | EUG | P | 4975168 |
HOMEOWNER | ER | R | 06/17/2015 | tighten up all light ground screws ---------- add outlet at pantry counter top --------- remove switch in up stair closet ------------- no mcc in either panel | CRAIG | CRAIG | | ER | R | 4975163 |
HOMEOWNER | ER | R | 06/10/2015 | not ready ---- consultation | CRAIG | CRAIG | | ER | R | 4971064 |
HOMEOWNER | ER | R | 05/19/2015 | consultation | MATTHEW | MATTHEW | | ER | R | 4957443 |
HOMEOWNER | ER | R | 05/14/2015 | consultation | MATTHEW | MATTHEW | | ER | R | 4954919 |
HOMEOWNER | H= | C | 08/09/2017 | corrections made. note: vented crawl space, direct vent boiler radiant heat with instant potable hot water, no a/c. | PAULO | PAULO | | H= | C | 5589960 |
AMERICAN PRIDE PLUMBING | HWP+ | C | 07/20/2017 | complete. | PAULO | PAULO | | HWP+ | C | 5571072 |
HOMEOWNER | H= | P | 07/20/2017 | need the following-- all un insulated heat pipe to be above insulation, installation manual and specs to radiator panels for proper clearances. rest ok. note: vented crawl space, direct vent boiler radiant heat with instant potable hot water, no a/c. | PAULO | PAULO | | H= | P | 5571068 |
HOMEOWNER | HC | C | 07/23/2015 | RELEASE METER | LUKE | LUKE | | HC | C | 4999599 |
HOMEOWNER | HRR | C | 07/23/2015 | NOTE: NEED TO CHECK BOILER AND VENTING AT FINAL NOTE: VENTED CRAWL SPACE. | LUKE | LUKE | | HRR | C | 4999598 |
AMERICAN PRIDE PLUMBING | HO | C | 11/10/2014 | | TIM | TIM | | HO | C | 4851369 |
AMERICAN PRIDE PLUMBING | HO | R | 10/28/2014 | 10lb test at house on new riser with both risers at road open (no plugs or caps) ? need more info, call 799-2860 | TED | TED | | HO | R | 4843448 |
AMERICAN PRIDE PLUMBING | HI | C | 10/20/2014 | 1 1/4'' boiler, range, dryer | TED | TED | | HI | C | 4838028 |
AMERICAN PRIDE PLUMBING | HWP | P | 10/20/2014 | by final insulate all piping in cross vented crawlspace | TED | TED | | HWP | P | 4838027 |
AMERICAN PRIDE PLUMBING | P= | C | 09/26/2016 | certificate of potable water to scanning | TED | TED | | P= | C | 5301871 |
AMERICAN PRIDE PLUMBING | P= | P | 09/22/2016 | need certificate of potable water, rest ok | TED | TED | | P= | P | 5299592 |
AMERICAN PRIDE PLUMBING | P= | R | 09/20/2016 | have not had an outside under ground water line inspection from well to house, (looks like pvc sch 40 was used from well pit up under footer into crawlspace), need certificate of potable water, need water hammers on washer box and dish washer supply, need trap guard on laundry room floor drain, note: R.P. back flow in crawlspace | TED | TED | | P= | R | 5298232 |
AMERICAN PRIDE PLUMBING | PTO | C | 10/20/2014 | NOTE : CRAWL SPACE , NO IRRIGATION , BACK FLOW REQUIRED FOR YARD HYDRANT BY FINAL . POTABLE WATER CERT BY FINAL | GABE | GABE | | PTO | C | 4837827 |
AMERICAN PRIDE PLUMBING | PB | C | 07/18/2014 | | GABE | GABE | | PB | C | 4779620 |
AMERICAN PRIDE PLUMBING | PB | R | 07/17/2014 | lost test, no water piping at this time | TED | TED | | PB | R | 4778835 |