HOMEOWNER | B= | C | 02/10/2020 | All other required Final inspections are complete. (This is a computer generated result) | BOBF | BOBF | | B= | C | 6477745 |
HOMEOWNER | B= | P | 02/12/2016 | . Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | BOBF | BOBF | | B= | P | 5134067 |
HOMEOWNER | BE | C | 09/08/2015 | | JANE | JANE | | BE | C | 5031373 |
HOMEOWNER | BSP | R | 02/17/2015 | not ready for a final | DALE | DALE | | BSP | R | 4903821 |
HOMEOWNER | BIN | C | 10/06/2014 | | DALE | DALE | | BIN | C | 4829166 |
HOMEOWNER | BFR | C | 10/06/2014 | eng. on file | DALE | DALE | | BFR | C | 4829165 |
HOMEOWNER | BLA | C | 10/01/2014 | | DALE | DALE | | BLA | C | 4826927 |
HOMEOWNER | BIN | P | 09/29/2014 | at garage only | DALE | DALE | | BIN | P | 4824927 |
HOMEOWNER | BFR | R | 09/29/2014 | need stamped eng. | DALE | DALE | | BFR | R | 4824926 |
HOMEOWNER | BLA | R | 09/29/2014 | not complete | DALE | DALE | | BLA | R | 4824925 |
HOMEOWNER | BFR | R | 09/18/2014 | electric panel not rated / need eng. for trusses / fireblock fireplace / strap stair landing and hanger / complete er | DALE | DALE | | BFR | R | 4818606 |
HOMEOWNER | BSP | R | 09/11/2014 | missing truss lat. as noted on plans / clip rear porch trusses? / front porch ok | DALE | DALE | | BSP | R | 4814292 |
HOMEOWNER | BSP | T | 08/21/2014 | PAID (REC#1215283) PLAN SPLICE FEE: $50 by: RUSSELL for Mechanical: Revised duct design completely | RUSSELL | RUSSELL | | BSP | T | 4801663 |
HOMEOWNER | BTR | C | 08/12/2014 | | DALE | DALE | | BTR | C | 4795691 |
HOMEOWNER | BFI | C | 05/16/2014 | R-10 at wal;kout | CHRISM | CHRISM | | BFI | C | 4740116 |
HOMEOWNER | BFD | P | 05/16/2014 | open hole on file, soils from original house, drain usable isolate and float | CHRISM | CHRISM | | BFD | P | 4740114 |
HOMEOWNER | BFN | C | 05/16/2014 | eng report on file | CHRISM | CHRISM | | BFN | C | 4740111 |
HOMEOWNER | BFT | C | 05/16/2014 | eng report on file | CHRISM | CHRISM | | BFT | C | 4740110 |
DILLER ELECTRIC LLC | E= | C | 01/29/2016 | both a/c ok both 30 amp 3rd a/c pre wire | CRAIG | CRAIG | | E= | C | 5126837 |
DILLER ELECTRIC LLC | E= | L | 01/28/2016 | occupied home, no one on site 2:38-------- contractor will need to provide ladder for re-inspect | MATTHEW | MATTHEW | | E= | L | 5125619 |
DILLER ELECTRIC LLC | E= | T | 03/12/2015 | PAID (REC#1310556): 40 amp max on 8-3nm, gfci devices need to be readily accessible (x-mas outlets and heater outlets in garage), exterior lights need to work (switches fed off basement circuits), neutrals doubled in sub-panels (need to check all panels), handle tie mcc's, hard wire and breaker locks for cooking equipment (need paperwork for cooktop), gfci alarm circuit in mech room, cap wires and blank boxes in unfinished area of basement, install smoke for basement, protect nm in basement, need lights and gfci outlets in unfinished area of basements, land nm in boxes in unfinished area of basement---------------- complete re-inspect | MATTHEW | MATTHEW | | E= | T | 4916222 |
DILLER ELECTRIC LLC | E= | R | 03/11/2015 | no one home | CRAIG | CRAIG | | E= | R | 4915343 |
DILLER ELECTRIC LLC | ER | C | 03/06/2015 | new wall and vault in basement only ok | CRAIG | CRAIG | | ER | C | 4913151 |
DILLER ELECTRIC LLC | E= | R | 03/06/2015 | all outside outlets need to be tr / wr type ----------------- all a/c and hot tub disconnect needs to be grounded ----------------- install back porch outlets ground level -------------------- no power to a/c outlet ---------------- need ladder for x mas outlets ---------------- all outlets in laundry room by sink needs to be gfi protected ---------------------- all kitchen outlets need to be tr type ------------------- garage outlets need to be gfi protected ------------- all outlets in mech room need to be gfi protected ----------------- well disconnect install 20 amp fuse and ko plug ------------- didn' t check all panels ------------------- complete re inspect
note need to talk to supervisor about home owner not finishing basement | CRAIG | CRAIG | | E= | R | 4913150 |
DILLER ELECTRIC LLC | ER | C | 10/29/2014 | inter system bonding terminal attached to the ufer with a irreversible crimp | CRAIG | CRAIG | | ER | C | 4844747 |
DILLER ELECTRIC LLC | EUG | C | 10/29/2014 | 2 - 2" pvc on both sides and in front of garage | CRAIG | CRAIG | | EUG | C | 4844746 |
DILLER ELECTRIC LLC | EP | C | 10/15/2014 | 4/w # 2 al to 100 amp sub panel in basement 4/w 4/0 al to 200 amp sub panel in garage ufer is irreversible clamp in office in basement | CRAIG | CRAIG | | EP | C | 4834928 |
DILLER ELECTRIC LLC | ES | C | 10/15/2014 | Residential Underground: 400 amp 2 runs of 4/0 al new res. seal meter | CRAIG | CRAIG | | ES | C | 4834925 |
DILLER ELECTRIC LLC | EUG | C | 10/09/2014 | 2 - sets of 4/0 URD | TOMC | TOMC | | EUG | C | 4832013 |
DILLER ELECTRIC LLC | ER | C | 09/18/2014 | 250 ser installed above insulation--- derating not required | MATTHEW | MATTHEW | | ER | C | 4818895 |
DILLER ELECTRIC LLC | ER | P | 09/15/2014 | mech room and can lights for patio not ready------------------- need 250 feeder out of insulation for 200 amp sub-panel | MATTHEW | MATTHEW | | ER | P | 4815962 |
DILLER ELECTRIC LLC | ER | T | 09/11/2014 | PAID (REC#1219684): Junction box for well wire behind sauna needs to be accessible, panel and mech room not complete at rough, I need to talk to Dale re: panel in separation wall. | MATTHEW | MATTHEW | | ER | T | 4814304 |
DILLER ELECTRIC LLC | ER | R | 09/08/2014 | need approval thru bldg inspector for panel in separation wall, trim attic, seal return air, j-box for well wire needs to be accessible (buried behind sauna)---------------- mech room and panels not complete---------------ufer access in basement office---------- finished basement; check mcc's at time of service inspection | MATTHEW | MATTHEW | | ER | R | 4811675 |
DILLER ELECTRIC LLC | ER | R | 09/02/2014 | not ready---- additional electrical to be installed---- complete re-inspect | MATTHEW | MATTHEW | | ER | R | 4808300 |
DILLER ELECTRIC LLC | ER | R | 08/28/2014 | need to add receptacles by sliders upstairs and down , light and receptacle in attic by steam unit finish panels and safe area | TOMC | TOMC | | ER | R | 4806389 |
RIAL HEATING AND AIR CONDITIONING, INC. | H= | C | 02/19/2015 | Final ok Note: No a/c condensers. Fin B. | MARK | MARK | | H= | C | 4905586 |
RIAL HEATING AND AIR CONDITIONING, INC. | H= | L | 02/18/2015 | No access. No call ahead, no garage code. Re schedule when ready. | MARK | MARK | | H= | L | 4904416 |
RIAL HEATING AND AIR CONDITIONING, INC. | H16 | C | 02/13/2015 | PERFORMANCE TEST SCANNED | JON | JON | | H16 | C | 4902955 |
RIAL HEATING AND AIR CONDITIONING, INC. | HC | C | 09/16/2014 | RELEASE METER | JON | JON | | HC | C | 4816472 |
RIAL HEATING AND AIR CONDITIONING, INC. | HRR | C | 09/16/2014 | finished basement verification of condensate drains. Need performance test. check vent terminations | JON | JON | | HRR | C | 4816471 |
RIAL HEATING AND AIR CONDITIONING, INC. | HRR | P | 09/15/2014 | Still missing nail protection for lower level dryer vent. Electricians on site said they would fill holes in return bays where wires go through. Check return bay in floor joist at re inspection. Need to look into condensate location. Will update notes in the am. | MARK | MARK | | HRR | P | 4816371 |
RIAL HEATING AND AIR CONDITIONING, INC. | HRR | P | 09/12/2014 | There are still several holes that need to be filled in return bays. Main lvl 3 lg knockouts open, wall returns with wires running through (several) Still need nail protection for lower level dryer duct. Need a new plumbing inspection as condensate drain pipes were tied into sanitary pipe system after the final. (2locations) | MARK | MARK | | HRR | P | 4815129 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | HI | C | 08/25/2014 | 10 lb test is good. Note: 2" main. (3) furn, (2) w/h, (2) f/p, future BBQ, Future Fire pit. Garage has (2) future heaters. | MARK | MARK | | HI | C | 4803091 |
RIAL HEATING AND AIR CONDITIONING, INC. | HRR | P | 08/22/2014 | Need to plumb condensate drain piping to both attic units. Will need to provide nail protection for lower level dryer vent. Will need to complete duct work in basement (Not finished during inspection) Need to provide M/A to both laundry rms by final.Will need to seal electrical penetrations in return bays on both lvl's (Several) Need to seal cabling openings in return bays in bsmnt. Will need Performance test docs prior to completion. Note: Carrier furnaces (2) 60K (1) 80K. (2) 75K w/h with powered vents (4" dia pipe). All furnaces are 2 pipe direct vent. (2) a/c (attic units) | MARK | MARK | | HRR | P | 4802296 |
HOMEOWNER | H16 | C | 08/21/2014 | Need Equipment cut sheet reviewed and approved prior to final on furnace, coil and condenser | RUSSELL | RUSSELL | | H16 | C | 4801743 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | P= | C | 03/03/2015 | NOTE : UNFINISHED BASEMENT , RP IN MEC , DRAIN LINES FROM STEAM UNITS CONNECTED AT SINK WASTE . POTABLE WATER CERT TO SCANNING | GABE | GABE | | P= | C | 4910861 |
HOMEOWNER | P16 | P | 09/15/2014 | CONDENSATE IN ATTIC NEEDS TO TERMINATE AT LAV DRAINS AS DISCUSSED WITH PLUMBER ON 8-22 | LEE | LEE | | P16 | P | 4815556 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PTO | C | 08/22/2014 | 3 IN CO AT WATER COOLER , IN MEC AND WEST BED ROOM . BAR SINK WATER OK . NOTE FINISHED BASEMENT , IRRIGATION | GABE | GABE | | PTO | C | 4802575 |
HOMEOWNER | PWO | C | 08/18/2014 | | TIM | TIM | | PWO | C | 4798876 |
UNIQUE RADIANT HTG. & PLBG. | PB | C | 05/21/2014 | | GABE | GABE | | PB | C | 4742813 |