CASCO ENTERPRISES, INC. | B= | C | 12/02/2014 | | DALE | DALE | | B= | C | 4862933 |
CASCO ENTERPRISES, INC. | B= | R | 11/24/2014 | Additional Inspections Required: External Agency Inspection HD= by HEALTHDEPT is not Completed yet. need window well cover at patio / can not have door swing over stairs / need handrail at stairs / insulate basement walls / need ladder at attic access / hearth not per specs / install house # on house | DALE | DALE | | B= | R | 4859669 |
CASCO ENTERPRISES, INC. | BIN | C | 09/24/2014 | | DALE | DALE | | BIN | C | 4821907 |
CASCO ENTERPRISES, INC. | BFR | C | 09/23/2014 | | DALE | DALE | | BFR | C | 4821298 |
CASCO ENTERPRISES, INC. | BFR | P | 09/18/2014 | foam and firestop / ok to insulate | DALE | DALE | | BFR | P | 4818737 |
CASCO ENTERPRISES, INC. | BLA | C | 09/18/2014 | | DALE | DALE | | BLA | C | 4818736 |
CASCO ENTERPRISES, INC. | BFR | R | 09/12/2014 | no truss calcs / foam and firestop / float walls at garage / block garage door brackets / strap top plates | DALE | DALE | | BFR | R | 4815154 |
CASCO ENTERPRISES, INC. | BIN | P | 09/11/2014 | Qualified third party energy inspection documentation must be presented at time of final building (B=) inspection | INTERNET | INTERNET | | BIN | P | 4814274 |
CASCO ENTERPRISES, INC. | BSP | P | 09/11/2014 | wood stove rough at frame inspection | DALE | DALE | | BSP | P | 4814135 |
CASCO ENTERPRISES, INC. | BSP | P | 08/22/2014 | porch frame ok | DALE | DALE | | BSP | P | 4802284 |
CASCO ENTERPRISES, INC. | BSP | R | 08/20/2014 | need rbd plans | DALE | DALE | | BSP | R | 4800247 |
CASCO ENTERPRISES, INC. | BSP | T | 07/09/2014 | PAID (REC#1207423) ADDITIONAL PLAN REVIEW TIME: $50 From: SHELLEY add door to patio | SHELLEY | SHELLEY | | BSP | T | 4773738 |
CASCO ENTERPRISES, INC. | BFD | P | 06/26/2014 | soils on file drain usable isolate and float, clear BFN | CHRISM | CHRISM | | BFD | P | 4766153 |
CASCO ENTERPRISES, INC. | BFN | P | 06/26/2014 | need stamped copy of foundation inspection report | CHRISM | CHRISM | | BFN | P | 4766150 |
CASCO ENTERPRISES, INC. | BFT | C | 06/26/2014 | eng report on file | CHRISM | CHRISM | | BFT | C | 4766147 |
CASCO ENTERPRISES, INC. | BSP | T | 06/26/2014 | PAID (REC#1203961) PLAN SPLICE FEE: $50 by: SHELLEY for Construction: added basement square footage and added rear patio | SHELLEY | SHELLEY | | BSP | T | 4765811 |
CASCO ENTERPRISES, INC. | BFN | P | 06/24/2014 | AUTHORIZED INSPECTION BY ENGINEER | TERRI | TERRI | TERRI | BFN | P | 4764523 |
CASCO ENTERPRISES, INC. | BFT | P | 06/24/2014 | AUTHORIZED INSPECTION BY ENGINEER | TERRI | TERRI | TERRI | BFT | P | 4764522 |
RELIANT K ELECTRIC INC. | E= | C | 11/12/2014 | | MATTHEW | MATTHEW | | E= | C | 4852653 |
RELIANT K ELECTRIC INC. | E= | R | 11/10/2014 | gfci for water heater needs to be readily accessible | MATTHEW | MATTHEW | | E= | R | 4851713 |
RELIANT K ELECTRIC INC. | E= | R | 11/05/2014 | gfci outlet in well pit, correct grounding in well disconnect, no power to garage and OH door outlets, switching in laundry room not working, hood circuit needs to be dedicated, front gfci won't set, need switch outlets id'd so I can check, guard crawler lights, install outlet for water heater ------ 30 amp a/c ok------ | MATTHEW | MATTHEW | | E= | R | 4849217 |
RELIANT K ELECTRIC INC. | ER | C | 09/11/2014 | | MATTHEW | MATTHEW | | ER | C | 4814486 |
RELIANT K ELECTRIC INC. | ES | C | 09/11/2014 | Residential Underground: 200A 3 wire new res. Meter is set needs seal. | MATTHEW | MATTHEW | | ES | C | 4814483 |
RELIANT K ELECTRIC INC. | ER | R | 09/09/2014 | I didn't see the wire from the well to the controller or to the well controller from the panel; call me if I missed it-------------------- unfinished basement, 6-3nm to cooking | MATTHEW | MATTHEW | | ER | R | 4812747 |
RELIANT K ELECTRIC INC. | ES | R | 09/09/2014 | remove temp and land service conductors in pedestal | MATTHEW | MATTHEW | | ES | R | 4812746 |
RELIANT K ELECTRIC INC. | EUG | C | 08/15/2014 | 3/w 4/0 al | CRAIG | CRAIG | | EUG | C | 4798173 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 11/21/2014 | unfinished basement, a/c installed, conditioned crawlspace, performance test to scanning | TED | TED | | H= | C | 4858388 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | R | 11/19/2014 | Furn vent plugged with stucco. W/H needs a condensate loop/drain. Need perf test. equip change doc. Need ladder to access crawl for inspection. Check w/h vent term clearance to grade at final/ Reinspect all. | MARK | MARK | | H= | R | 4856282 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HC | C | 09/11/2014 | RELEASE METER | MARK | MARK | | HC | C | 4814137 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 09/11/2014 | Rough ok. Will require a performance test by final. Will require an equipment change letter by final. Also at final, check OSA duct in crawl, full of water at time of rough. Check for crawl space being conditioned or vented. Has return no supply, no moisture bvarrier in crawl.
| MARK | MARK | | HRR | C | 4814131 |
FENTON PLUMBING & HEATING INC | HI | C | 09/11/2014 | 10 lb test ok. Note:1" main. Furn, w/h.
| MARK | MARK | | HI | C | 4814121 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | R | 09/10/2014 | duct lay out not plan lay out, house lay out not to plan, no equipment schedule | TED | TED | | HRR | R | 4813117 |
FENTON PLUMBING & HEATING INC | P= | C | 11/20/2014 | no sprinkler stub | TIM | TIM | | P= | C | 4857364 |
FENTON PLUMBING & HEATING INC | PTO | C | 09/11/2014 | POTABLE WATER CERT BY FINAL . NOTE : PARTIAL BASEMENT UNFINISHED CRAWL SPACE. NO IRRIGATION | GABE | GABE | | PTO | C | 4814204 |
FENTON PLUMBING & HEATING INC | PB | C | 08/12/2014 | | TIM | TIM | | PB | C | 4795130 |
FENTON PLUMBING & HEATING INC | PB | R | 08/11/2014 | no access, provide ladder | TED | TED | | PB | R | 4794338 |
HOMEOWNER | PWO | C | 06/30/2014 | need certificate of potable water by final, yard hydrant has backflow in pit | TED | TED | | PWO | C | 4768074 |