MAHLER GC GENERAL CONTRACTING COMPANY | B= | C | 02/19/2015 | All other required Final inspections are complete. (This is a computer generated result) | NATHAN | NATHAN | | B= | C | 4905286 |
MAHLER GC GENERAL CONTRACTING COMPANY | B= | P | 02/13/2015 | Additional Inspections Required. | NATHAN | NATHAN | | B= | P | 4902991 |
MAHLER GC GENERAL CONTRACTING COMPANY | B= | R | 02/13/2015 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet, External Agency Inspection Z= by ZONINGF is not Completed yet (Contact: Janet at 322-2028) (This is a computer generated result) | SYSTEM | SYSTEM | | B= | R | 4902992 |
MAHLER GC GENERAL CONTRACTING COMPANY | BFR | C | 11/07/2014 | entire okay | NATHAN | NATHAN | | BFR | C | 4851084 |
MAHLER GC GENERAL CONTRACTING COMPANY | BFR | C | 11/07/2014 | entire | NATHAN | NATHAN | | BFR | C | 4851052 |
INTERMOUNTAIN POWER SERVICES INC | BSP | T | 11/04/2014 | PAID (REC#1230527) PLAN SPLICE FEE: $50 by: SHELBY for Electrical: designate panels as future | SHELBY | SHELBY | | BSP | T | 4848321 |
MAHLER GC GENERAL CONTRACTING COMPANY | B16 | C | 10/15/2014 | LEFT PHONE MESSAGE FOR JOHN AT 8:05 STATING THAT I RELEASED A GAS METER 8031 | JERRYF | JERRYF | | B16 | C | 4834699 |
MAHLER GC GENERAL CONTRACTING COMPANY | BLA | C | 10/06/2014 | | NATHAN | NATHAN | | BLA | C | 4829335 |
MAHLER GC GENERAL CONTRACTING COMPANY | BFR | P | 09/15/2014 | exterior sheer okay | NATHAN | NATHAN | | BFR | P | 4816196 |
MAHLER GC GENERAL CONTRACTING COMPANY | BFR | P | 09/09/2014 | north tower framing okay / ledger corrected | NATHAN | NATHAN | | BFR | P | 4812877 |
MAHLER GC GENERAL CONTRACTING COMPANY | BFR | R | 09/08/2014 | north tower frame still missing lag bolts at ledger by hangers / south tower frame okay / main roof ledgers corrected column and tower fire blocking okay | NATHAN | NATHAN | | BFR | R | 4811846 |
INTERMOUNTAIN POWER SERVICES INC | BSP | T | 08/26/2014 | PAID (REC#1216198) PLAN SPLICE FEE: $50 by: DOUG for Electrical: Added a new panel for fourth TI dropped HE to 100A E3 new photometric. | DOUG | DOUG | | BSP | T | 4804330 |
MAHLER GC GENERAL CONTRACTING COMPANY | BFR | P | 08/20/2014 | tower ledger bolts and lower roof ledger bolting missing bolts parapet wall bracing, bolts and blocking okay | NATHAN | NATHAN | | BFR | P | 4800729 |
MAHLER GC GENERAL CONTRACTING COMPANY | BFN | C | 08/13/2014 | engineer letter for pilasters in place of pads picked up / foundation is complete | NATHAN | NATHAN | | BFN | C | 4796311 |
MAHLER GC GENERAL CONTRACTING COMPANY | BFT | C | 08/13/2014 | all open excavation letters and compaction picked up. | NATHAN | NATHAN | | BFT | C | 4796267 |
MAHLER GC GENERAL CONTRACTING COMPANY | BFR | P | 08/13/2014 | lag bolting of roof ledgers at perimeter okay / lag bolting at window headers to beam saddles okay / parapet wall blocking for attachment of bracing okay NO BRACING HAS BEEN INSTALLED YET / | NATHAN | NATHAN | | BFR | P | 4796266 |
MAHLER GC GENERAL CONTRACTING COMPANY | BFI | C | 07/03/2014 | 2" rigid 24"of exterior face | NATHAN | NATHAN | | BFI | C | 4771289 |
MAHLER GC GENERAL CONTRACTING COMPANY | BFN | P | 06/30/2014 | with stamped openex and engineer letter of footer pads to pilasters foundation okay / interior pads into pilasters 2 mats installed. | NATHAN | NATHAN | | BFN | P | 4768178 |
MAHLER GC GENERAL CONTRACTING COMPANY | BFT | P | 06/25/2014 | ---------POC MARK 460-2466 --------ufer is in / interior pads are going to be pilasters and letter to follow / exterior footer and pads okay | NATHAN | NATHAN | | BFT | P | 4765214 |
MAHLER GC GENERAL CONTRACTING COMPANY | BSP | P | 06/06/2014 | inspections assigned to nathan | BLAKE | BLAKE | | BSP | P | 4752549 |
INTERMOUNTAIN POWER SERVICES INC | E= | C | 11/06/2014 | | TIMA | TIMA | | E= | C | 4850006 |
INTERMOUNTAIN POWER SERVICES INC | E= | R | 10/31/2014 | BOND WATER LINE,NEED PERMANT LABEL ON SERVICE DISCONNECT WITH AVAILABLE FAULT CURRENT AND DATE ,BOND LIGHT POLES,NEED FA BREAKER IDENTIFIED RED,NEED ACCESS TO ROOF,NEED ARC FLASH STICKERS FOR ALL EQUIPMENT,NEED HANDLE TIE FOR BASEBOARD HEATER,INSTALL IN-USE COVER PROPERLY-----STILL NEED DRAWINGS REVISED SHOWING PANELS ARE FUTURE LETTER WILL NOT WORK FOR THIS---- | TIMA | TIMA | | E= | R | 4846586 |
INTERMOUNTAIN POWER SERVICES INC | ER | P | 09/16/2014 | NEED DRAWINGS REVISED TO SHOW ALL TENANT SPACE PANELS AND FEEDERS ARE FUTURE | TIMA | TIMA | | ER | P | 4817244 |
INTERMOUNTAIN POWER SERVICES INC | ES | C | 09/16/2014 | Commercial Service: 600 AMP 4/W OK TO ENERGIZE NEED METER SET FOR HOUSE PANEL ONLY 100 AMP 4/W | TIMA | TIMA | | ES | C | 4817243 |
INTERMOUNTAIN POWER SERVICES INC | EUG | P | 08/26/2014 | SERVICE LATERAL TO SERVICE OK | TIMA | TIMA | | EUG | P | 4804183 |
INTERMOUNTAIN POWER SERVICES INC | EUG | P | 08/14/2014 | SERVICE LATERAL TO SW CORNER OF BUILDING | TIMA | TIMA | | EUG | P | 4797538 |
INTERMOUNTAIN POWER SERVICES INC | EUG | P | 08/12/2014 | SIGN AND WEST SITE LIGHTING FEEDS COMPLETE TO BUILDING---STILL NEED TO SEE SERVICE LATERAL TO BUILDING---- | TIMA | TIMA | | EUG | P | 4795434 |
INTERMOUNTAIN POWER SERVICES INC | EUG | P | 07/24/2014 | FROM SIGN TO PARKING LOT OK, WEST SITE LIGHTING BETWEEN POLES OK, FUTURE SERVICE LATERAL FOR SOUTH BUILDING GOOD FROM TRANSFORMER ACROSS DRIVEWAY AND CAPPED AT PARKING LOT | TIMA | TIMA | | EUG | P | 4783723 |
PRESTIGE MECHANICAL CONTRACTORS,INC | H= | C | 11/06/2014 | OK | JERRYF | JERRYF | | H= | C | 4849753 |
PRESTIGE MECHANICAL CONTRACTORS,INC | HC | R | 10/16/2014 | CANCEL GAS METER FOR 8031 | JERRYF | JERRYF | | HC | R | 4835569 |
PRESTIGE MECHANICAL CONTRACTORS,INC | HC | C | 10/16/2014 | RELEASE GAS METER FOR ADDRESS 8025 | JERRYF | JERRYF | | HC | C | 4835568 |
PRESTIGE MECHANICAL CONTRACTORS,INC | H16 | C | 10/15/2014 | GAS LINES AT BACK OF BUILDING TAGGED IN THIS ORDER FROM SOUTH END 8028 - 8027 - 8029 - 8031 HAS NO GAS PIPING INSTALLED YET - METERS WILL NOT BE RELEASED UNTIL ALL ADDRESSES ARE POSTED AT FRONT OF BUILDING | JERRYF | JERRYF | | H16 | C | 4835122 |
PRESTIGE MECHANICAL CONTRACTORS,INC | HC | R | 10/15/2014 | DO NOT RELEASE GAS METER FOR 8025 THROUGH 8031 UNTIL ALL ADDRESSES ARE POSTED - CANCEL PREVIOUS METER RELEASE | JERRYF | JERRYF | | HC | R | 4835116 |
PRESTIGE MECHANICAL CONTRACTORS,INC | HC | C | 10/15/2014 | RELEASE METER ON 8031 | JERRYF | JERRYF | | HC | C | 4834677 |
PRESTIGE MECHANICAL CONTRACTORS,INC | HC | C | 10/09/2014 | RELEASE METER - METER RELEASE FOR RTU 1 -2 AND 3 ONLY - RTU 1 COMPLETE - THE FOLLOWING RTU GAS LINES WILL BE COMPLETED ON FUTURE TENANT FINISH PERMITS - RTU'S 2 AND 3 GAS LINES STUBBED INTO BUILDING ONLY | JERRYF | JERRYF | | HC | C | 4831591 |
PRESTIGE MECHANICAL CONTRACTORS,INC | HI | C | 10/09/2014 | RTU 1 COMPLETE - GAS FOR THE FOLLOWING RTU'S 2 -3 AND 4 WILL BE COMPLETED UNDER TENANT FINISH PERMITS - GAS LINES FOR 2 AND 3 STUBBED INTO BUILDING | JERRYF | JERRYF | | HI | C | 4831574 |
RIAL HEATING AND AIR CONDITIONING, INC. | H= | C | 10/09/2014 | ALL FINAL GAS CONNECTIONS AT THE FOLLOWING RTU'S 2 - 3 AND 4 WILL BE UNDER FUTURE TENANT PERMITS - RTU 1 COMPLETE - RTU 2 AND 3 GAS STUBBED INTO BUILDING | JERRYF | JERRYF | | H= | C | 4831571 |
RIAL HEATING AND AIR CONDITIONING, INC. | H= | P | 09/10/2014 | PARTIAL PENDING ALL GAS CONNECTIONS AT 4 ROOF TOP UNITS | JERRYF | JERRYF | | H= | P | 4813068 |
PRESTIGE MECHANICAL CONTRACTORS,INC | P= | C | 11/06/2014 | final for core and shell only, will need permits for tenant finishes. | DICK | DICK | | P= | C | 4849372 |
PRESTIGE MECHANICAL CONTRACTORS,INC | PTO | C | 11/06/2014 | top for core and shell only ok. will need permits for tenant finishes. | DICK | DICK | | PTO | C | 4849370 |
PRESTIGE MECHANICAL CONTRACTORS,INC | P= | P | 11/05/2014 | see pto | MARTY | MARTY | | P= | P | 4849126 |
PRESTIGE MECHANICAL CONTRACTORS,INC | PTO | P | 11/05/2014 | will talk to dick.before signing | MARTY | MARTY | | PTO | P | 4849124 |
PRESTIGE MECHANICAL CONTRACTORS,INC | PB | C | 08/28/2014 | gs and ss trunk lines ok. 1 floor drain ok. vents for future grease traps ok. 2" water into building will run overhead to mech. room. | DICK | DICK | | PB | C | 4806139 |