ASPEN VALLEY CUSTOM HOMES, LLC | B= | C | 05/21/2015 | finished basement, deck in | DALE | DALE | | B= | C | 4959191 |
ASPEN VALLEY CUSTOM HOMES, LLC | B= | R | 05/19/2015 | no exposed foam at basement and insulate wall at mech. room | DALE | DALE | | B= | R | 4957284 |
ASPEN VALLEY CUSTOM HOMES, LLC | BIN | C | 12/10/2014 | | DALE | DALE | | BIN | C | 4868552 |
ASPEN VALLEY CUSTOM HOMES, LLC | BSP | P | 12/05/2014 | post connections ok / piers have not been inspected? | DALE | DALE | | BSP | P | 4865901 |
ASPEN VALLEY CUSTOM HOMES, LLC | BFR | C | 12/03/2014 | | DALE | DALE | | BFR | C | 4863757 |
ASPEN VALLEY CUSTOM HOMES, LLC | BSP | R | 11/26/2014 | deck piers already poured provide engineer letter or expose piers to bottom | BOBF | BOBF | | BSP | R | 4861576 |
ASPEN VALLEY CUSTOM HOMES, LLC | BFR | R | 11/26/2014 | install Jack straps per narrow wall detail / strap vault at peak over slider / missing 2t 22 and st 20 straps each end of vault / okay to insulate | BOBF | BOBF | | BFR | R | 4861571 |
ASPEN VALLEY CUSTOM HOMES, LLC | BLA | C | 10/31/2014 | | BOBF | BOBF | | BLA | C | 4846417 |
ASPEN VALLEY CUSTOM HOMES, LLC | BFD | C | 06/20/2014 | | ED | ED | | BFD | C | 4762411 |
ASPEN VALLEY CUSTOM HOMES, LLC | BFI | C | 06/20/2014 | | ED | ED | | BFI | C | 4762384 |
ASPEN VALLEY CUSTOM HOMES, LLC | BFT | C | 06/20/2014 | | ED | ED | | BFT | C | 4762383 |
ASPEN VALLEY CUSTOM HOMES, LLC | BFN | C | 06/20/2014 | engineer inspection letters for footing, foundation, design, soils report from previous permit #(F70774), on file, drain daylights to the west, R 10 at walkout. | ED | ED | | BFN | C | 4762381 |
JET ELECTRIC, INC. | E= | C | 04/28/2015 | | MATTHEW | MATTHEW | | E= | C | 4944818 |
JET ELECTRIC, INC. | E= | R | 04/20/2015 | install jet tub | CRAIG | CRAIG | | E= | R | 4939135 |
JET ELECTRIC, INC. | E= | R | 04/16/2015 | gfi master bath fire place ------------- lite green basement bedroom closet light to close to shelve ----------------------- basement bedroom not afci ------------- master bath steamer need a disconnect within sight ------------- uncover ufer ---------- install inter system bonding terminal ------------ front outlet in use cover not opening 90 degree -------------- large j - box under panel ???? ------------ a/c ok 30 amp ---------- complete re inspect ---------------------- need to install jet tub | CRAIG | CRAIG | | E= | R | 4937648 |
JET ELECTRIC, INC. | ES | C | 11/25/2014 | Residential Overhead: 200 AMP W/W NEW RES. SEAL METER | CRAIG | CRAIG | | ES | C | 4860014 |
JET ELECTRIC, INC. | ER | C | 11/25/2014 | | CRAIG | CRAIG | | ER | C | 4860012 |
JET ELECTRIC, INC. | ES | R | 11/17/2014 | install bushings on ends of both risers | MATTHEW | MATTHEW | | ES | R | 4854870 |
JET ELECTRIC, INC. | ER | R | 11/17/2014 | ser cable coiled in ceiling above master bath, what are the stubs at main level fireplace?, add outlet in wall with return air in living room and at basement slider, I didn't see well wiring (call me if I missed it)---------------finished basement, 200 amp sub-panel in garage and #2al sub-panel in mech room ok (not breakered) #6al to cooking-------- central vac outlets wired---------- stub for spa in master bath | MATTHEW | MATTHEW | | ER | R | 4854869 |
JET ELECTRIC, INC. | EUG | C | 11/07/2014 | 4/0al feeder | MATTHEW | MATTHEW | | EUG | C | 4850923 |
JET ELECTRIC, INC. | EUG | R | 11/06/2014 | need equipment ground ran with feeder | MATTHEW | MATTHEW | | EUG | R | 4850167 |
MILLER HEATING & AIR CONDITIONING, INC. | H= | C | 05/04/2015 | correction made, note: both stats are in mech. room on wall with sensors on 1st floor and basement, access in basement bathroom ceiling for zone valves | TED | TED | | H= | C | 4948446 |
MILLER HEATING & AIR CONDITIONING, INC. | H= | R | 04/22/2015 | install stat for main level, (are basement stats in mech. room on wall? ), could not find water heater vent outlet, missing zone control access in bathroom ceiling (bathroom backs up to mech. room), note: finished basement, a/c installed, transfer openings to mech. room | TED | TED | | H= | R | 4941040 |
MILLER HEATING & AIR CONDITIONING, INC. | HC | C | 11/18/2014 | RELEASE METER | TED | TED | | HC | C | 4855599 |
MILLER HEATING & AIR CONDITIONING, INC. | HRR | C | 11/18/2014 | by final need access to zone control dampers in basement bathroom ceiling above toilet, note: roof deck to be foamed | TED | TED | | HRR | C | 4855596 |
MILLER HEATING & AIR CONDITIONING, INC. | HRR | R | 11/14/2014 | missing bath fan venting on master bathroom fan, insulate bath fan vents in attic, seal and screw missed joints in basement ceiling, note: finished basement, a/c rough, outside air to return, zone system, duct design | TED | TED | | HRR | R | 4854055 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | HI | C | 11/06/2014 | 1 1/4'' furnace, w/h, range, 2-fireplaces, future gas outlet at wood burning fireplace, 2-bbq | TED | TED | | HI | C | 4849689 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | P= | C | 05/15/2015 | certificate of potable water to scanning | TED | TED | | P= | C | 4955033 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | P= | P | 05/07/2015 | need certificate of potable water, note: finished basement, 3/4'' pvb installed | TED | TED | | P= | P | 4950711 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PTO | C | 11/05/2014 | finished basement, aav at laundry sink, bar sink vent through roof | TED | TED | | PTO | C | 4848793 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PWO | C | 09/09/2014 | SLEEVED AND STUBBED IN UNDER STAIRS . NOTE : POTABLE WATER CERT BY FINAL | GABE | GABE | | PWO | C | 4812388 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PB | C | 06/27/2014 | | DICK | DICK | | PB | C | 4767431 |