HOMEOWNER | B= | C | 05/19/2015 | finished basement | DALE | DALE | | B= | C | 4957242 |
HOMEOWNER | BIN | C | 12/10/2014 | | DALE | DALE | | BIN | C | 4868467 |
HOMEOWNER | BFR | C | 12/10/2014 | | DALE | DALE | | BFR | C | 4868466 |
HOMEOWNER | BLA | C | 12/08/2014 | | DALE | DALE | | BLA | C | 4867008 |
HOMEOWNER | BFR | R | 11/25/2014 | 45 brace truss laterials every 20ft / strap top plates at rake walls / foam and firestop / ok to insulate | DALE | DALE | | BFR | R | 4860006 |
HOMEOWNER | BFT | C | 08/08/2014 | ok per eng. | DALE | DALE | | BFT | C | 4793737 |
HOMEOWNER | BFN | C | 08/08/2014 | ok per eng. / all paperwork on file / float | DALE | DALE | | BFN | C | 4793736 |
HOMEOWNER | BFD | C | 08/08/2014 | | DALE | DALE | | BFD | C | 4793735 |
HOMEOWNER | BFD | R | 08/06/2014 | | DALE | DALE | | BFD | R | 4791305 |
HOMEOWNER | BFT | R | 08/06/2014 | | DALE | DALE | | BFT | R | 4791304 |
HOMEOWNER | BFN | R | 08/06/2014 | call me in the morning / open hole and foundation design not on site | DALE | DALE | | BFN | R | 4791303 |
HOMEOWNER | BFD | P | 08/05/2014 | need open hole report | DALE | DALE | | BFD | P | 4790378 |
HOMEOWNER | BFT | P | 08/05/2014 | | DALE | DALE | | BFT | P | 4790377 |
HOMEOWNER | BFN | P | 08/05/2014 | still need open hole report and foundation design | DALE | DALE | | BFN | P | 4790376 |
HOMEOWNER | BFT | R | 07/29/2014 | | DALE | DALE | | BFT | R | 4786281 |
HOMEOWNER | BFN | R | 07/29/2014 | need eng. report fot bft and bfn. / need foundation design and soils report | DALE | DALE | | BFN | R | 4786175 |
HOMEOWNER | BFD | R | 07/29/2014 | need soils report | DALE | DALE | | BFD | R | 4786171 |
HOMEOWNER | BFN | P | 07/07/2014 | ok for eng charles milligan of geoquest to do inspection | BLAKE | BLAKE | | BFN | P | 4771465 |
HOMEOWNER | BFT | P | 07/07/2014 | ok for eng charles milligan of geoquest to do inspection | BLAKE | BLAKE | | BFT | P | 4771464 |
ROMERO ELECTRIC, INC. | E= | C | 05/18/2015 | | CRAIG | CRAIG | | E= | C | 4956735 |
ROMERO ELECTRIC, INC. | E= | P | 05/15/2015 | afci protect nook | MATTHEW | MATTHEW | | E= | P | 4955851 |
ROMERO ELECTRIC, INC. | E= | R | 05/11/2015 | need permit for detached garage, need outlets in exterior wall of lower level pulled out, generator not hooked up, back exterior outlet that is switched is not gfci protected, strap seal tite at a/c, front exterior lights need to be installed so water won't enter thru back, switch at top of stairs needs to be grounded, over hang at peninsula is too far, need to afci dining outlets----------- 30 amp a/c ok---------per dean: permit for detached garage is not required and generator hook up can be on separate permit | MATTHEW | MATTHEW | | E= | R | 4952526 |
ROMERO ELECTRIC, INC. | ER | C | 11/13/2014 | finished basement, no mcc's----------- cut-in boxes are to be used in basement on exterior wall; need devices left out for final | MATTHEW | MATTHEW | | ER | C | 4853388 |
ROMERO ELECTRIC, INC. | ES | C | 11/13/2014 | Residential Underground: 200 amp 3/w: new res------- meter is set; need seal | MATTHEW | MATTHEW | | ES | C | 4853387 |
ROMERO ELECTRIC, INC. | EUG | C | 11/13/2014 | service lateral to home and feeder from home to detached garage-------- contractor needs to pull separate permit for detached garage | MATTHEW | MATTHEW | | EUG | C | 4853386 |
KNAUF HEATING AND AIR CONDITIONING | H= | C | 05/18/2015 | correction made, mantel removed, door removed to laundry room | TED | TED | | H= | C | 4956166 |
KNAUF HEATING AND AIR CONDITIONING | H= | R | 05/08/2015 | connect gas to back up generator, need water heater combustion air (solid door to laundry room that has mech. closet in it, 10x10 transfer opening above door is make up air for dryer) mech. closet has louver door, fireplace mantel to low, under cut bedroom doors for return air path, complete furnace vent outlet, note: finished basement, a/c installed | TED | TED | | H= | R | 4951618 |
KNAUF HEATING AND AIR CONDITIONING | HC | C | 11/24/2014 | RELEASE METER | TED | TED | | HC | C | 4859616 |
KNAUF HEATING AND AIR CONDITIONING | HRR | C | 11/24/2014 | correction made | TED | TED | | HRR | C | 4859576 |
KNAUF HEATING AND AIR CONDITIONING | HRR | P | 11/20/2014 | need to check on dryer booster fan, need to screw and seal missed joints, need to frame under duct work in garage to allow insulation, need transfer opening for supply feeding area under front door landing, need furnace change letter, note: a/c rough, outside air to return, zone system, duct design | TED | TED | | HRR | P | 4857314 |
BLUE IGUANA PLUMBING, INC. | HI | C | 11/12/2014 | 1 1/2'' furnace, w/h, fireplace, range, bbq, generator | TED | TED | | HI | C | 4852366 |
BLUE IGUANA PLUMBING, INC. | P= | C | 05/07/2015 | finished basement, 3/4'' pvb installed , certificate of potable water to scanning | TED | TED | | P= | C | 4950857 |
BLUE IGUANA PLUMBING, INC. | PTO | C | 11/12/2014 | finished basement | TED | TED | | PTO | C | 4852369 |
HOMEOWNER | PWO | C | 10/03/2014 | | TIM | TIM | | PWO | C | 4828414 |
HOMEOWNER | PB | C | 08/18/2014 | | GABE | GABE | | PB | C | 4798801 |