DOUBLE DIAMOND HOMES, INC. | B= | C | 11/12/2014 | finished basement, deck in | DALE | DALE | | B= | C | 4852126 |
DOUBLE DIAMOND HOMES, INC. | B= | R | 11/10/2014 | stairs not complete | DALE | DALE | | B= | R | 4851404 |
DOUBLE DIAMOND HOMES, INC. | B= | R | 10/20/2014 | Additional Inspections Required: External Agency Inspection HD= by HEALTHDEPT is not Completed yet, Plumbing Final Inspection is not Completed yet. install house # / need cover on window well at front / garage door can not swing over landing, 1 1/2" max. / 20" hearth extension / insulate mech. room walls / complete all other inspections | DALE | DALE | | B= | R | 4838231 |
DOUBLE DIAMOND HOMES, INC. | BLA | C | 08/18/2014 | | DALE | DALE | | BLA | C | 4798697 |
DOUBLE DIAMOND HOMES, INC. | BFR | C | 08/13/2014 | | DALE | DALE | | BFR | C | 4796197 |
DOUBLE DIAMOND HOMES, INC. | BIN | C | 08/13/2014 | | DALE | DALE | | BIN | C | 4796192 |
DOUBLE DIAMOND HOMES, INC. | BIN | P | 08/11/2014 | complete bfr | DALE | DALE | | BIN | P | 4794214 |
DOUBLE DIAMOND HOMES, INC. | BFR | R | 08/11/2014 | need spark shield under fireplace | DALE | DALE | | BFR | R | 4794213 |
DOUBLE DIAMOND HOMES, INC. | BIN | P | 07/28/2014 | complete bfr | DALE | DALE | | BIN | P | 4785098 |
DOUBLE DIAMOND HOMES, INC. | BFR | P | 07/28/2014 | complete fireplace | DALE | DALE | | BFR | P | 4785097 |
DOUBLE DIAMOND HOMES, INC. | BFR | P | 07/24/2014 | fireplace not complete | DALE | DALE | | BFR | P | 4783532 |
DOUBLE DIAMOND HOMES, INC. | BSP | P | 07/11/2014 | portal frames at rear wall ok | CHRISM | CHRISM | | BSP | P | 4775020 |
DOUBLE DIAMOND HOMES, INC. | BSP | P | 07/08/2014 | deck frame and membrane ok, check ledger lags at frame | CHRISM | CHRISM | | BSP | P | 4772344 |
DOUBLE DIAMOND HOMES, INC. | BSP | P | 07/02/2014 | deck piers ok | CHRISM | CHRISM | | BSP | P | 4769859 |
DOUBLE DIAMOND HOMES, INC. | BFI | C | 06/18/2014 | R-10 at walkout | CHRISM | CHRISM | | BFI | C | 4760678 |
DOUBLE DIAMOND HOMES, INC. | BFD | C | 06/18/2014 | soils on file drain usable isolate and float | CHRISM | CHRISM | | BFD | C | 4760677 |
DOUBLE DIAMOND HOMES, INC. | BFN | C | 06/18/2014 | eng report and design on file | CHRISM | CHRISM | | BFN | C | 4760676 |
DOUBLE DIAMOND HOMES, INC. | BFT | C | 06/18/2014 | eng report on file | CHRISM | CHRISM | | BFT | C | 4760674 |
POLARIZED ELECTRIC INC | E= | C | 10/17/2014 | no a/c, hot tub pre-wire | MATTHEW | MATTHEW | | E= | C | 4836922 |
POLARIZED ELECTRIC INC | E= | R | 10/13/2014 | protect nm in garage and under stairs, gfci test can't be behind washer, need spa access and gfci needs to be dead face, hard wire cooktop, no power to dining room light, , need access for appliance garage outlet, where is the dish/disp breaker, verify disposal outlet at island is not on small appliance circuit, tc cable at well needs to be installed in conduit------------- hot tub pre-wire | MATTHEW | MATTHEW | | E= | R | 4833421 |
POLARIZED ELECTRIC INC | ER | C | 07/24/2014 | tc cable in unfinished area needs to be installed in conduit by final | MATTHEW | MATTHEW | | ER | C | 4783309 |
POLARIZED ELECTRIC INC | ES | C | 07/24/2014 | Residential Underground: 200 amp 3/w: new res------ meter is set--- need seal | MATTHEW | MATTHEW | | ES | C | 4783307 |
POLARIZED ELECTRIC INC | EUG | C | 07/23/2014 | remainder of ditch to house ok | MATTHEW | MATTHEW | | EUG | C | 4782537 |
POLARIZED ELECTRIC INC | ER | R | 07/23/2014 | add outlet at handrail in living room, seal return air in basement ceiling, tc cable needs to be installed in conduit---------- finished basement, no mcc's, 6-3 nm to cooking | MATTHEW | MATTHEW | | ER | R | 4782532 |
POLARIZED ELECTRIC INC | EUG | P | 07/17/2014 | back side if garage ditch collapsed in needs to be dug out | TOMC | TOMC | | EUG | P | 4779146 |
BRUNO'S HEATING & COOLING | H= | C | 09/29/2014 | Final ok. Fin. Bsmnt, no a/c. Has OSA and Louver door to mech. No mantle at lower level gas f/p.
| MARK | MARK | | H= | C | 4824414 |
CORNERSTONE PLUMBING INC | HI | C | 07/22/2014 | 11/4 TO MEC . 2 POUND REG . 2 WH , 1 FURNACE , 1 DRYER , 1 BBQ , 1 RANG , 1 FP | GABE | GABE | | HI | C | 4781520 |
BRUNO'S HEATING & COOLING | HC | C | 07/21/2014 | RELEASE METER | JEFFL | JEFFL | | HC | C | 4783769 |
BRUNO'S HEATING & COOLING | HRR | C | 07/21/2014 | Notes-- finished basement.. direct vent furnace.. Duct design.. OSA to return. Equipment cert to scanning. | JEFFL | JEFFL | | HRR | C | 4780521 |
CORNERSTONE PLUMBING INC | HO | C | 07/17/2014 | 10 lb test is ok. Note: 300' of 3/4" PE pipe from meter at road to house. Will only carry 57K BTU on low pressure system. If equipment exceeds this, a med pressure system will be required and an approval letter will need to be received prior to a gas final. | MARK | MARK | | HO | C | 4778754 |
CORNERSTONE PLUMBING INC | P= | C | 11/07/2014 | r-p installed | TIM | TIM | | P= | C | 4850272 |
CORNERSTONE PLUMBING INC | P= | P | 10/21/2014 | RECEIVED / SCANNED POTABLE WATER REPORT | LEE | LEE | | P= | P | 4839132 |
CORNERSTONE PLUMBING INC | P= | P | 10/13/2014 | need backflow at yard hydrant (ok to e-mail pics when installed) need potable water cert | TIM | TIM | | P= | P | 4833316 |
HOMEOWNER | PWO | C | 07/24/2014 | NOTE : PEX SLEEVED | GABE | GABE | | PWO | C | 4783612 |
CORNERSTONE PLUMBING INC | PTO | C | 07/22/2014 | NOTE : FINISHED BASEMENT . NO IRRIGATION | GABE | GABE | | PTO | C | 4781514 |
CORNERSTONE PLUMBING INC | PB | C | 06/24/2014 | CORRECTIONS MADE . NOTE : POTABLE WATER CERT BY FINAL | GABE | GABE | | PB | C | 4764314 |
CORNERSTONE PLUMBING INC | PB | R | 06/23/2014 | NO TEST | GABE | GABE | | PB | R | 4763132 |