HOMEOWNER | BE | L | 03/18/2024 | Renewed for $1,414.00 at 3/18/2024 11:10:51 AM (Receipt#2043459) | REBECCAM | REBECCAM | | BE | L | 8024619 |
HOMEOWNER | BLA | C | 09/29/2017 | | BOBF | BOBF | | BLA | C | 5641096 |
HOMEOWNER | BE | L | 09/19/2017 | Renewed at 9/19/2017 9:22:52 AM | TERRI | TERRI | | BE | L | 5629652 |
HOMEOWNER | BIN | C | 03/01/2017 | | DALE | DALE | | BIN | C | 5428897 |
HOMEOWNER | BFR | P | 03/01/2017 | complete stairs to garage and theater room, can check on final / eng. on file for truss and post | DALE | DALE | | BFR | P | 5428848 |
HOMEOWNER | BFR | R | 02/08/2017 | fireblock all chases and at drops / strap studs at girder trusses / need eng. for deleted tele-post at dining room / stairs not in yet to basement garage and theater room need truss fix for E04 / missing truss lateral on FO3 / ok to insulate | DALE | DALE | | BFR | R | 5410424 |
HOMEOWNER | BFR | R | 02/03/2017 | to many items to list, walked house with owner | DALE | DALE | | BFR | R | 5406649 |
HOMEOWNER | BTR | C | 12/29/2016 | | DAKOTAB | DAKOTAB | | BTR | C | 5379032 |
HOMEOWNER | BSP | T | 10/10/2016 | PAID (REC#1370434) PLAN SPLICE FEE: $50 by: DALEH for Mechanical: splice | DALEH | DALEH | | BSP | T | 5314671 |
HOMEOWNER | BSP | T | 09/21/2016 | PAID (REC#1368996) ADDITIONAL PLAN REVIEW TIME: $50 From: JIMA splice : changed storage to mech room in basement nad added mech closet on upper floor | JIMA | JIMA | | BSP | T | 5299270 |
HOMEOWNER | BSP | P | 08/22/2016 | eng. on file for porches | DALE | DALE | | BSP | P | 5274922 |
HOMEOWNER | BSP | P | 08/18/2016 | porches and posts at upper level of house okay / trusses with posts over open area at north east corner of house okay / need detail for rafter framing and connections at entry, rear patio and lower patio | BOBF | BOBF | | BSP | P | 5273048 |
HOMEOWNER | BSP | P | 03/09/2016 | steel frame for first floor okay | BOBF | BOBF | | BSP | P | 5151722 |
HOMEOWNER | BFD | C | 10/01/2015 | design and open hole on file | BOBF | BOBF | | BFD | C | 5048172 |
HOMEOWNER | BFD | R | 09/30/2015 | need stamped soils with drain design and clean copy of foundation design to complete drain inspection | BOBF | BOBF | | BFD | R | 5047938 |
HOMEOWNER | BFN | C | 09/08/2015 | balance of foundation okay including t piers at back of house / provide clean stamped foundation design at next inspection | BOBF | BOBF | | BFN | C | 5032149 |
HOMEOWNER | BFN | P | 06/26/2015 | hign walls completed, - walkout wall next | ED | ED | | BFN | P | 4981658 |
HOMEOWNER | BFN | P | 03/26/2015 | north side wall to east corner OK | DANE | DANE | | BFN | P | 4924491 |
HOMEOWNER | BFN | P | 01/23/2015 | wall ok as marked on plans | DALE | DALE | | BFN | P | 4889431 |
HOMEOWNER | BSP | P | 11/14/2014 | footings at front ok | DALE | DALE | | BSP | P | 4853737 |
HOMEOWNER | BFT | C | 10/29/2014 | | DALE | DALE | | BFT | C | 4843905 |
HOMEOWNER | BFT | P | 10/04/2014 | house portion as marked on plans | DALE | DALE | | BFT | P | 4828654 |
HOMEOWNER | BFT | T | 10/02/2014 | PAID (REC#1223765) AFTER-HOURS INSPECTION: $200 From: TERRI Sat BFT at 9 a.m. | TERRI | TERRI | | BFT | T | 4827690 |
HOMEOWNER | E= | P | 05/01/2024 | will need afci protection on bedrooms, family rooms, dining rm, living rooms,den,rec rooms, closets, halls, and any similar rooms-----will need to protect nm cable in garage running horizontal thru studs | RANDY | RANDY | | E= | P | 8071235 |
HOMEOWNER | ES | C | 05/01/2024 | Residential Underground: service is set and complete----no action needed-----400 amp | RANDY | RANDY | | ES | C | 8071204 |
HOMEOWNER | ER | C | 02/02/2017 | | BRET | BRET | | ER | C | 5405504 |
HOMEOWNER | ER | R | 02/01/2017 | use approved ground clips | BRET | BRET | | ER | R | 5404279 |
HOMEOWNER | ER | R | 01/31/2017 | install ground clips in all lighting boxes. strap mc in basement master | BRET | BRET | | ER | R | 5403187 |
HOMEOWNER | ES | R | 01/27/2017 | not called in by homeowner | BRET | BRET | | ES | R | 5400032 |
HOMEOWNER | ER | R | 01/26/2017 | install boxes exterior lights and receptacles. nail plate kitchen sink wall, under cab lights on small appliance, add receptacles mud room, upper master, upper loft area, wire bath fan , add smoke to bedroom 4 note open ceiling in theater, mech and mud room to lower garage. add receptacle foyer,hand rail between fireplace and hall basement. | BRET | BRET | | ER | R | 5399631 |
HOMEOWNER | ES | P | 09/21/2016 | Residential Underground: corrections made----still need mountain view to set new pedestal for 400 amp service | RANDY | RANDY | | ES | P | 5298924 |
HOMEOWNER | ES | R | 09/06/2016 | need to remove equipment ground from service lateral, attach to ufer and land on neutral bar in service disconnect, need metal raceway for service conductors inside----------- homeowner needs to coordinate with MTVE to have new 400 amp pedestal installed (service lateral does not enter pedestal at this time; homeowner would like new pedestal installed over his service conduit) | MATTHEW | MATTHEW | | ES | R | 5286180 |
HOMEOWNER | EUG | R | 11/10/2015 | address on permit not matching house address which is 13195 peregrine way need to correction made note : 3" pvc from meter to house and 10/3 uf from house to well head | CRAIG | CRAIG | | EUG | R | 5076938 |
HOMEOWNER | H= | P | 04/26/2024 | STILL NEED 2 LB APPROVAL LETTER FROM GAS PURVEYOR AND 3 MEDIUM PESSURE STICKERS INSTALLED PRIOR TO 3 REGULATORS. Photo upload requested. If unfamiliar with uploading photos for an inspection, please click the following link: https://youtu.be/QS0hdGSBA6o / NOTE / FINISHED BASEMENT / DIRECT VENT FURNACE(X3) / PRE-EXISTING OUTSIDE AIR TO FURNACE RETURN(X2) / A/C ROUGH, COIL AND LINESET / A/C ROUGH, LINESET ONLY(X2) / | JONH | JONH | | H= | P | 8066945 |
HOMEOWNER | HWP | C | 01/26/2017 | 55# test ok. | MICHAELS | MICHAELS | | HWP | C | 5399734 |
HOMEOWNER | HC | C | 11/23/2016 | RELEASE METER | MICHAELS | MICHAELS | | HC | C | 5352738 |
HOMEOWNER | HI | C | 11/23/2016 | 10# test ok. 2" 2lb. black main to 3-furn, w/h, 4-fp, c-top, bbq, fire pit, 3-garage heaters. BY FINAL: need 2lb. letter on file, labels on all exposed medium pressure lines, regulators in place at garage heaters, both lower level mech rooms. | MICHAELS | MICHAELS | | HI | C | 5352735 |
MOUNTAIN AIR COMFORT SYSTEMS, INC. | HRR | C | 11/16/2016 | Rough ok. Note: finished basement, 6" osa x2, a/c rough(lineset only) x2, a/c rough(coil and lineset) x1, direct vent furnace x3. BY FINAL: need duct leakage report. | MICHAELS | MICHAELS | | HRR | C | 5346621 |
HOMEOWNER | HI | R | 11/15/2016 | Main line must exit structure the same size and terminate on correct side of high pressure riser, can not conceal 1/2" black unions behind fireplaces. Trip fee waived. | MICHAELS | MICHAELS | | HI | R | 5345091 |
MOUNTAIN AIR COMFORT SYSTEMS, INC. | HRR | T | 11/15/2016 | PAID (REC#1382446) Plans on site do not include mechanical. Will require 4th trip. | MICHAELS | MICHAELS | | HRR | T | 5345038 |
MOUNTAIN AIR COMFORT SYSTEMS, INC. | H16 | C | 11/09/2016 | Inspection changed to H16 for new HVAC contractor on site. Need stamped approved plans on site for inspection. Need fall protection for main stairwell. | MICHAELS | MICHAELS | | H16 | C | 5340557 |
HOMEOWNER | HI | R | 11/08/2016 | Low test. Need main line terminated outside structure, need gas lines completed to inside of fireplace boxes. Re-inspect all. | MICHAELS | MICHAELS | | HI | R | 5339482 |
HOMEOWNER | HRR | R | 10/25/2016 | Not ready, need approved plans on site, fireplaces still being installed, duct work incomplete. Re-inspect all. Trip fee waived. | MICHAELS | MICHAELS | | HRR | R | 5327354 |
HOMEOWNER | HWP | R | 10/06/2016 | Need air test on piping at min. 55#, need insulation under pipe at min. R-5, need sleeves in place on gas risers before pouring concrete. | MICHAELS | MICHAELS | | HWP | R | 5312521 |
HOMEOWNER | HO | C | 08/05/2016 | 10# test ok. 3/4" poly jumpers from outside foundation to bbq and fire pit. | MICHAELS | MICHAELS | | HO | C | 5263281 |
HOMEOWNER | HO | R | 08/01/2016 | Changed inspection from an HI to an HO, there is no interior gas piping. As previously noted, air test needs to be 10 lbs on a 30 lb gauge. Yellow 18 gauge solid wire required for tracer wire. Also polyethylene gas pipe cannot be brought into a structure, it is for outsise underground only. | MARK | MARK | | HO | R | 5258378 |
HOMEOWNER | HO | R | 07/26/2016 | Need 10# test on 30# gauge, need tracer wire on poly gas lines, need sleeves on lines through concrete, need ditch 18" deep from existing grade. | MICHAELS | MICHAELS | | HO | R | 5254111 |
HOMEOWNER | PWO | P | 12/05/2016 | WELL TIE IN VERIFIED , WILL NEED POTABLE WATER CERT BY FINAL | GABE | GABE | | PWO | P | 5360413 |
HOMEOWNER | PTO | C | 12/05/2016 | CORRECTIONS MADE , ALL WATER ON TEST . WILL NEED RECIRC INSTALLED AND TEMPERING AT ALL DECK MOUNTED TUB FAUCETS AND POTABLE WATER CERT BY FINAL . PWO IS PARTIAL CHECK NOTES | GABE | GABE | | PTO | C | 5360396 |
HOMEOWNER | PTO | P | 11/23/2016 | DWV AND WATER ON TEST ON NORTH SIDE , NO TEST ON EAST SIDE WATER , DWV OK , NEED TO CHECK BOCCA AND NAIL PROTECTION THROUGH OUT , SET AND SECURE CLOSET FLANGES THROUGH OUT , | GABE | GABE | | PTO | P | 5353012 |
HOMEOWNER | PB | C | 08/05/2016 | ALL CORRECTIONS MADE | GABE | GABE | | PB | C | 5263167 |
HOMEOWNER | PB | P | 08/01/2016 | TEST OK , 2 INCH LINE NEAR STAIRS IS BACK GRADED , NEED TO BED ALL PIPE | GABE | GABE | | PB | P | 5258757 |
HOMEOWNER | PB | R | 07/26/2016 | NEED TO POST ADDRESS , BED ALL DWV AND CHECK GRADE THROUGH OUT , LOST TEST | GABE | GABE | | PB | R | 5254507 |
HOMEOWNER | PWO | P | 11/10/2015 | NEED TO DROP WATER LINE 1 FOOT THROUGH OUT , ONLY AT 4 , LEAVE TIE IN OPEN FOR INSPECTION | GABE | GABE | | PWO | P | 5076534 |