CONSTRUCTION BY GENESIS, INC. | B= | C | 11/06/2014 | finished basement, no deck | DALE | DALE | | B= | C | 4849889 |
CONSTRUCTION BY GENESIS, INC. | BIN | C | 09/03/2014 | | DALE | DALE | | BIN | C | 4808706 |
CONSTRUCTION BY GENESIS, INC. | BFR | C | 08/28/2014 | under stair area part of mechanical room / okay to insulate | BOBF | BOBF | | BFR | C | 4806524 |
CONSTRUCTION BY GENESIS, INC. | BFR | R | 08/26/2014 | no truss calcs / strong back on gable ends and brace every 4ft. / frame under stairs 24" oc / secure tele-pot to beam / no inspection on narrow braced wall, covered up _ | DALE | DALE | | BFR | R | 4804316 |
CONSTRUCTION BY GENESIS, INC. | BLA | C | 08/25/2014 | | DALE | DALE | | BLA | C | 4803431 |
CONSTRUCTION BY GENESIS, INC. | BSP | P | 08/14/2014 | porch frames ok | DALE | DALE | | BSP | P | 4797548 |
CONSTRUCTION BY GENESIS, INC. | BFD | C | 07/08/2014 | soils on file drain usable isolate and float | CHRISM | CHRISM | | BFD | C | 4772579 |
CONSTRUCTION BY GENESIS, INC. | BFN | C | 07/08/2014 | design and eng report on file | CHRISM | CHRISM | | BFN | C | 4772578 |
CONSTRUCTION BY GENESIS, INC. | BFT | C | 07/08/2014 | eng report on file | CHRISM | CHRISM | | BFT | C | 4772575 |
CONSTRUCTION BY GENESIS, INC. | BFN | P | 06/25/2014 | AUTHORIZED INSPECTION BY ENGINEER | BPHILLIPS | BPHILLIPS | BPHILLIPS | BFN | P | 4764867 |
CONSTRUCTION BY GENESIS, INC. | BFT | P | 06/25/2014 | AUTHORIZED INSPECTION BY ENGINEER | BPHILLIPS | BPHILLIPS | BPHILLIPS | BFT | P | 4764866 |
POSITIVE ELECTRIC, LLC | E= | C | 10/27/2014 | a/c pre-wire | MATTHEW | MATTHEW | | E= | C | 4842748 |
POSITIVE ELECTRIC, LLC | ER | C | 08/21/2014 | finished basement, 100 amp sub-panel ok (not breakered, no mcc's), 3-20 at service, #6al in insulation 8-3nm to cooking---------------------- by final add outlet at handrail---------------------- | MATTHEW | MATTHEW | | ER | C | 4801635 |
POSITIVE ELECTRIC, LLC | ES | C | 08/21/2014 | Residential Underground: 200 amp 3/w: new res---- meter is set; need seal | MATTHEW | MATTHEW | | ES | C | 4801634 |
POSITIVE ELECTRIC, LLC | EUG | C | 07/22/2014 | 3/w 4/0 al | CRAIG | CRAIG | | EUG | C | 4781902 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 11/04/2014 | | TIM | TIM | | H= | C | 4848230 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | T | 11/03/2014 | PAID (REC#1230227): no change from last inspection | TED | TED | | H= | T | 4847034 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | R | 10/31/2014 | install zone dampers and controls, need clearance from single wall water heater vent, note: finished basement, no a/c, transfer openings | TED | TED | | H= | R | 4845954 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HC | C | 08/14/2014 | RELEASE METER | TED | TED | | HC | C | 4797127 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 08/14/2014 | finished basement, no a/c, outside air to return, duct design | TED | TED | | HRR | C | 4797126 |
CORNERSTONE PLUMBING INC | HI | C | 08/12/2014 | 1 1/4'' furnace, w/h, fireplace, range | TED | TED | | HI | C | 4795452 |
CORNERSTONE PLUMBING INC | P= | C | 11/05/2014 | 2- 3/4'' pvb installed | TED | TED | | P= | C | 4848745 |
CORNERSTONE PLUMBING INC | P= | P | 10/21/2014 | install sprinkler pvb on both outside stubs or an r/p in basement for 2 sprinkler stubs and connect water piping in basement to stubs note: certificate of potable water to scanning | TED | TED | | P= | P | 4838663 |
CORNERSTONE PLUMBING INC | PTO | C | 08/12/2014 | by final expose wrap on 3" stack in mech room, sleeve h2o thru slab | TIM | TIM | | PTO | C | 4795368 |
HOMEOWNER | PWO | C | 07/16/2014 | PEX UNDER FOOTER | GABE | GABE | | PWO | C | 4777567 |
CORNERSTONE PLUMBING INC | PB | C | 07/11/2014 | | TED | TED | | PB | C | 4775157 |