HOMEOWNER | B= | C | 06/05/2018 | Items corrected | TIMOTHYS | TIMOTHYS | | B= | C | 5864739 |
GILLIS HOMES, INC. | B= | P | 08/01/2016 | missing guards at the open-sided walking surfaces that have more than 30" of fall within 36" of the walking surfaces installed around the home / missing code compliant numeric address posted on the structure / other corrections from previous inspection okay -- Schedule a new Building Final when above items are complete. | BRIANB | BRIANB | | B= | P | 5258672 |
GILLIS HOMES, INC. | B= | P | 07/21/2016 | Temp CO: pending building final ( Expires: 8/20/2016 12:00:00 AM) | BPHILLIPS | BPHILLIPS | | B= | P | 5250209 |
GILLIS HOMES, INC. | B= | P | 07/20/2016 | Need landing poured at all exterior doors -- Need to install exterior lights to complete weather seal -- Crawlspace - No AC - No deck -- Schedule a new Building Final when above items are complete. | DAKOTAB | DAKOTAB | | B= | P | 5249986 |
GILLIS HOMES, INC. | B= | T | 07/19/2016 | PAID (REC#1343000) LOCKED at 1:03PM -- No answer at front door | DAKOTAB | DAKOTAB | | B= | T | 5248495 |
GILLIS HOMES, INC. | BLA | C | 07/06/2016 | | BOBF | BOBF | | BLA | C | 5238957 |
GILLIS HOMES, INC. | BLA | T | 07/05/2016 | PAID (REC#1339815) Still need to raise weep screed to 4" above all landscaped areas -- Still need to seal behind sill plate and remove all light fixtures | DAKOTAB | DAKOTAB | | BLA | T | 5237632 |
GILLIS HOMES, INC. | BLA | R | 05/10/2016 | weep screed must be a minimum of 2" above all paved areas including sidewalks and landings and 4" above all landscaped areas / need to seal behind sill cock and remove light fixtures / house appears to be occupied and no final inspections have been performed | BOBF | BOBF | | BLA | R | 5196259 |
GILLIS HOMES, INC. | BE | L | 05/09/2016 | Renewed for Full Fee at 5/9/2016 9:06:02 AM (Receipt#1328351) | TERRI | TERRI | | BE | L | 5194318 |
GILLIS HOMES, INC. | BE | L | 07/23/2015 | Renewed for 1/2 Fee at 7/23/2015 3:28:57 PM (Receipt#1276319) | MINDY | MINDY | | BE | L | 4999819 |
GILLIS HOMES, INC. | BFR | C | 11/26/2014 | | DALE | DALE | | BFR | C | 4861297 |
GILLIS HOMES, INC. | BIN | C | 11/26/2014 | | DALE | DALE | | BIN | C | 4861296 |
GILLIS HOMES, INC. | BFR | R | 11/20/2014 | strap top plates that are not overlapped at 1st floor and crawl space / ok to insulate / porch not on yet | DALE | DALE | | BFR | R | 4857567 |
GILLIS HOMES, INC. | BSP | T | 11/19/2014 | PAID (REC#1233129) PLAN SPLICE FEE: $50 by: DALEH for Mechanical | DALEH | DALEH | | BSP | T | 4856629 |
GILLIS HOMES, INC. | BSP | P | 11/19/2014 | PLAN SPLICE: (No Fee) by: SHELLEY for Construction: convert to conditioned crawl | SHELLEY | SHELLEY | | BSP | P | 4856588 |
GILLIS HOMES, INC. | BSP | C | 11/06/2014 | | BOBF | BOBF | | BSP | C | 4849985 |
GILLIS HOMES, INC. | BFN | C | 11/06/2014 | engineer letter for steel and eufer on file | BOBF | BOBF | | BFN | C | 4849984 |
GILLIS HOMES, INC. | BFT | C | 11/06/2014 | engineer letter for footer and open hole on file | BOBF | BOBF | | BFT | C | 4849979 |
GILLIS HOMES, INC. | BFN | P | 06/26/2014 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFN | P | 4765789 |
GILLIS HOMES, INC. | BFT | P | 06/26/2014 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFT | P | 4765788 |
HOMEOWNER | E= | C | 07/08/2016 | corrections made ----------- ufer under panel in crawl space | CRAIG | CRAIG | | E= | C | 5240340 |
HOMEOWNER | E= | R | 07/06/2016 | install inter-system bond terminal, provide disconnecting means for baseboard heat, remove gfci for micro (gfci protection not required), locate ufer----------- no a/c | MATTHEW | MATTHEW | | E= | R | 5238608 |
HOMEOWNER | ER | C | 10/29/2014 | whips for electric heaters -------------------- 2 - 20 2 - 10/3 to dryer / well 2 - 12/2 to electric heaters crawl space | CRAIG | CRAIG | | ER | C | 4844751 |
HOMEOWNER | ES | C | 10/29/2014 | Residential Underground: 200 amp 3/w new res. seal meter | CRAIG | CRAIG | | ES | C | 4844750 |
HOMEOWNER | EUG | C | 07/22/2014 | 3/w 4/0 al | CRAIG | CRAIG | | EUG | C | 4781827 |
HOMEOWNER | H= | C | 07/11/2016 | Transfer grilles to crawl space in laundry and master. | MICHAELS | MICHAELS | | H= | C | 5241919 |
HOMEOWNER | H= | P | 07/08/2016 | Pending installation of transfer grilles from main to crawl space for make up air. Note: all electric heat, exhaust fan and humidistat in place. | MICHAELS | MICHAELS | | H= | P | 5240748 |
HOMEOWNER | HRR | C | 11/10/2014 | Rough ok. Will be using elec. baseboard heat. Note: No duct, furn, a/c, elec w/h. Dryer vent and bath fans only. | MARK | MARK | | HRR | C | 4851854 |
HOMEOWNER | P= | C | 07/18/2016 | | JOEL | JOEL | | P= | C | 5247176 |
HOMEOWNER | P= | P | 07/12/2016 | POTABLE WATER CERT TO SCANNING , STILL NEED HAMMER ARRESTER IN LINE FOR URINAL | GABE | GABE | | P= | P | 5242366 |
HOMEOWNER | P= | P | 07/06/2016 | NEED POTABLE WATER CERT AND HAMMER ARRESTER AT URINAL AS NOTED IN TOP OUT , REST OK | GABE | GABE | | P= | P | 5238584 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PTO | C | 10/30/2014 | access to hammer arrestor at urinal at final | TIM | TIM | | PTO | C | 4845045 |
HOMEOWNER | PWO | C | 10/20/2014 | | TIM | TIM | | PWO | C | 4837958 |