WOOD WORKS UNLIMITED, INC. | B= | C | 06/11/2015 | finished basement, deck in | DALE | DALE | | B= | C | 4971710 |
WOOD WORKS UNLIMITED, INC. | BLA | C | 12/26/2014 | | DAN | DAN | | BLA | C | 4878166 |
WOOD WORKS UNLIMITED, INC. | BIN | C | 12/05/2014 | | DALE | DALE | | BIN | C | 4866266 |
WOOD WORKS UNLIMITED, INC. | BFR | C | 12/01/2014 | additional engineer letters on file for adding framing changes and adding changes to extend foundation wall at garage- finished basement | ED | ED | | BFR | C | 4862629 |
WOOD WORKS UNLIMITED, INC. | BSP | P | 10/23/2014 | front porch ok / rear porch posts ok, need eng. on roof | DALE | DALE | | BSP | P | 4840685 |
WOOD WORKS UNLIMITED, INC. | BSP | P | 09/02/2014 | 3 deck piers ok | DALE | DALE | | BSP | P | 4807784 |
WOOD WORKS UNLIMITED, INC. | BFI | C | 07/21/2014 | | DALE | DALE | | BFI | C | 4780734 |
WOOD WORKS UNLIMITED, INC. | BFD | C | 07/21/2014 | | DALE | DALE | | BFD | C | 4780733 |
WOOD WORKS UNLIMITED, INC. | BFT | C | 07/21/2014 | ok per eng. | DALE | DALE | | BFT | C | 4780732 |
WOOD WORKS UNLIMITED, INC. | BFN | C | 07/21/2014 | ok per eng. / all paperwork on file / float / ufer in per eng. | DALE | DALE | | BFN | C | 4780731 |
WOOD WORKS UNLIMITED, INC. | BFN | P | 07/15/2014 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFN | P | 4776613 |
WOOD WORKS UNLIMITED, INC. | BFT | P | 07/15/2014 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFT | P | 4776612 |
MEYER ELECTRIC | E= | C | 06/10/2015 | | CRAIG | CRAIG | | E= | C | 4971158 |
MEYER ELECTRIC | ES | C | 06/10/2015 | Residential Underground: 200 amp 3/w seal meter | CRAIG | CRAIG | | ES | C | 4971157 |
MEYER ELECTRIC | E= | C | 06/10/2015 | re moved insta hot ---------- re move outlet off of kitchen ---------- have paper work for generator can' t run whole house | CRAIG | CRAIG | | E= | C | 4971156 |
MEYER ELECTRIC | E= | T | 06/09/2015 | PAID (REC#1266969): see service----- 30 amp a/c | MATTHEW | MATTHEW | | E= | T | 4970181 |
MEYER ELECTRIC | ES | R | 06/09/2015 | need grounding electrode conductor to right service disconnect, grounding electrode conductor need to be bonded to sub-panel can where spliced, need access to front and back exterior outlets, need notarized letter from homeowner stating knowledge that generator will not run house and RBD is not responsible for any damages, need wr and tr outlet to generator outlet, white wires phased black at a/c, can't have gfci devices behind laundry and wet bar fridge and wet bar micro (not required at wet bar micro or wet bar fridge), gfci master bath outlet (low), provide paperwork showing gfci protection for floor heat in master bath, afci protect bath circuit for basement sinks in bedrooms and outlet in arch way off kitchen, vacuum requires a 30 amp circuit (12-2 on 20a), correct outlet spacing in kitchen under window, verify 2 circuits are provided for dish/disp/ insta-hot | MATTHEW | MATTHEW | | ES | R | 4970180 |
MEYER ELECTRIC | ES | R | 06/08/2015 | complete re-inspect: partial list------ grounding electrode conductors need to land at service disconnect (2), need equipment ground to sub-panel, need working clearance at all electrical equipment, label service disconnects 1 of 2 and 2 of 2 service disconnects | MATTHEW | MATTHEW | | ES | R | 4969192 |
MEYER ELECTRIC | ER | C | 06/08/2015 | rough completed 11-26-14 | MATTHEW | MATTHEW | | ER | C | 4969188 |
MEYER ELECTRIC | E= | R | 06/05/2015 | wet floor in house | CRAIG | CRAIG | | E= | R | 4968317 |
MEYER ELECTRIC | ES | R | 06/05/2015 | wet floor in house | CRAIG | CRAIG | | ES | R | 4968316 |
MEYER ELECTRIC | ES | R | 11/26/2014 | Residential Underground: not ready | TOMC | TOMC | | ES | R | 4861109 |
MEYER ELECTRIC | ER | C | 11/26/2014 | corrections made | TOMC | TOMC | | ER | C | 4861108 |
MEYER ELECTRIC | ER | R | 11/20/2014 | land nm in nook outlet box, nm whip in closet/ garage wall?, non-ic can in contact with combustibles in shadow box by wet bar, add outlet under same shadow box, need wire from well to controller installed, nm coiled by basement fireplace--------------------- finished basement, 2-20, 1-15 at garage panel, #2al sub-panel ok (not breaker'd) | MATTHEW | MATTHEW | | ER | R | 4857840 |
MEYER ELECTRIC | EUG | C | 08/19/2014 | 2 sets of 250 al service laterals from pedestal to home ok | MATTHEW | MATTHEW | | EUG | C | 4799620 |
BRUNO'S MECHANICAL INC. | H= | C | 06/09/2015 | correction made, back up generator installed | TED | TED | | H= | C | 4969856 |
O.M.A.G.M., INC. | HO | C | 06/02/2015 | under ground line from house to detached garage and future generator on side of main house (will need regulator at generator when connected) | TED | TED | | HO | C | 4964961 |
BRUNO'S MECHANICAL INC. | H= | P | 06/01/2015 | NEED TO SEAL HOLE OUT SIDE LINE SET, NEED TO INSTALL 6'' PIPE PER CODE IF YOU ARE USING IT FOR COMBUSTION AIR FOR WATER HEATERS IN MECHANICAL ROOM NEED INSTRUCTION BOOK ON SITE FOR UNIT HEATER'S. REST OK. HAS A/C, MANTEL'S HAVE CLEARANCE. FINISHED BASEMENT. | LUKE | LUKE | | H= | P | 4964362 |
BRUNO'S HEATING & COOLING | HC | C | 10/31/2014 | RELEASE METER | TED | TED | | HC | C | 4845993 |
BRUNO'S HEATING & COOLING | HRR | C | 10/31/2014 | finished basement, a/c rough on one furnace, outside air to both furnaces, duct design, garage heater b vent installed, (if 6'' duct into mech. room is to be used for water heaters combustion air it needs to be high, can not have low only combustion air) | TED | TED | | HRR | C | 4845992 |
BRUNO'S HEATING & COOLING | HRR | R | 10/30/2014 | duct lay out not to design (supplys added and others not installed), outside air to returns not on design, furnaces not to design, can not have low only outside combustion air to mech. room, complete basement fireplace framing, stopped inspection, reinspect all | TED | TED | | HRR | R | 4845402 |
O.M.A.G.M., INC. | HI | C | 10/16/2014 | 2lb system, 1'' 2-furnaces, 2-water heaters, 3-fireplaces, range, bbq, garage unit heater, 2lb outlet for future line to detached garage/barn | TED | TED | | HI | C | 4836051 |
J D PLUMBING AND HEATING LLC | P= | C | 06/04/2015 | finished basement, certificate of potable water to scanning | TED | TED | | P= | C | 4967036 |
J D PLUMBING AND HEATING LLC | PTO | C | 10/15/2014 | note: finished basement, back flow in basement for sprinkler and yard hydrants | TED | TED | | PTO | C | 4835149 |
HOMEOWNER | PWO | C | 08/14/2014 | | TIM | TIM | | PWO | C | 4797401 |
J D PLUMBING AND HEATING LLC | PB | C | 07/28/2014 | hub drain in mech. room off mech. room floor drain | TED | TED | | PB | C | 4784996 |