HOMEOWNER | B= | C | 01/15/2016 | All other required Final inspections are complete. (This is a computer generated result) | ED | ED | | B= | C | 5117002 |
HOMEOWNER | BE | C | 01/11/2016 | | JANE | JANE | | BE | C | 5113615 |
HOMEOWNER | B= | P | 07/15/2015 | building side ok, pending electrical and plumbing finals unfinished basement, rear attached deck. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet, Electrical Final Inspection is not Completed yet, Plumbing Final Inspection is not Completed yet. | ED | ED | | B= | P | 4994178 |
HOMEOWNER | BLA | C | 03/31/2015 | | DANE | DANE | | BLA | C | 4926597 |
HOMEOWNER | BSP | T | 03/16/2015 | PAID (REC#1253422) PLAN SPLICE FEE: $50 by: MICHAEL for Construction: Add room to garage and additional windows | MICHAELA | MICHAELA | | BSP | T | 4917948 |
HOMEOWNER | BFR | P | 03/13/2015 | frame okay pending splice for shop / okay to start drywall | BOBF | BOBF | | BFR | P | 4917223 |
HOMEOWNER | BIN | C | 03/13/2015 | | BOBF | BOBF | | BIN | C | 4917222 |
HOMEOWNER | BFR | R | 03/09/2015 | missing t-bracing at garage / garage shop not on plans / post under girder trusses / ok to insulate | DALE | DALE | | BFR | R | 4913793 |
HOMEOWNER | BFR | R | 03/03/2015 | To many items to list reinspect all | DALE | DALE | | BFR | R | 4910931 |
HOMEOWNER | BSP | P | 02/20/2015 | 9 deck piers ok | DALE | DALE | | BSP | P | 4906484 |
HOMEOWNER | BSP | R | 12/11/2014 | 2 porch piers ok | DALE | DALE | | BSP | R | 4869661 |
HOMEOWNER | BFI | C | 09/10/2014 | | DALE | DALE | | BFI | C | 4813365 |
HOMEOWNER | BFD | C | 09/10/2014 | | DALE | DALE | | BFD | C | 4813361 |
HOMEOWNER | BFD | R | 09/09/2014 | not complete | DALE | DALE | | BFD | R | 4812315 |
HOMEOWNER | BFN | C | 08/25/2014 | soils on file / drain usable / float | DALE | DALE | | BFN | C | 4803479 |
HOMEOWNER | BFT | C | 08/07/2014 | | DALE | DALE | | BFT | C | 4792449 |
HOMEOWNER | E= | C | 07/16/2015 | | MATTHEW | MATTHEW | | E= | C | 4994965 |
HOMEOWNER | E= | P | 07/15/2015 | missing cover plate front exterior outlet by front door, need to hard wire double oven and install breaker lock | MATTHEW | MATTHEW | | E= | P | 4994046 |
HOMEOWNER | E= | R | 07/14/2015 | exterior outlets need to be tr and wr, reverse polarity and switched neutral at x-mas lights (need outlets corrected to check for gfci protection), missing exterior outlets at front door, install inter-system bond terminal, west garage man door exterior light not working, can't cord and plug connect built in oven (will need breaker lock when hard wired), ground powder room light---------- no a/c | MATTHEW | MATTHEW | | E= | R | 4993193 |
HOMEOWNER | EP | C | 02/25/2015 | 100 amp 4/w new sub panel ok | CRAIG | CRAIG | | EP | C | 4908563 |
HOMEOWNER | ES | C | 02/25/2015 | Residential Underground: 200 amp 3/w new res seal meter | CRAIG | CRAIG | | ES | C | 4908562 |
HOMEOWNER | ER | C | 02/25/2015 | no mcc 6/3 cu to double oven unfinished basement no central vac | CRAIG | CRAIG | | ER | C | 4908561 |
HOMEOWNER | EUG | C | 02/11/2015 | service lateral from ped to home and uf on northeast side of house for ground lights | MATTHEW | MATTHEW | | EUG | C | 4901100 |
HOMEOWNER | H= | C | 07/14/2015 | NOTE: NO MANTEL, NO A/C, UNFINISHED BASEMENT, DIRECT VENT FURNACE. | LUKE | LUKE | | H= | C | 4993000 |
HOMEOWNER | HC | C | 06/15/2015 | Release Meter Meter is to be at house not street otherwise we need an Outside gas inspection. | JACK | JACK | | HC | C | 4972946 |
HOMEOWNER | HI | C | 03/06/2015 | 1'' furnace, water heater, fireplace (master bedroom), range, dryer (note: no meter release at this time, need outside under ground run and tested from meter at road to house riser, will need an approval letter for 2lb system) | TED | TED | | HI | C | 4912832 |
HOMEOWNER | HRR | C | 03/03/2015 | correction made | TED | TED | | HRR | C | 4910612 |
HOMEOWNER | HRR | L | 02/25/2015 | need bath fan vents insulated, install attic insulation shield, anchor master bedroom fireplace, note: unfinished basement, no a/c, duct design | TED | TED | | HRR | L | 4908112 |
HOMEOWNER | P= | C | 01/12/2016 | received potable water cert | TIM | TIM | | P= | C | 5114015 |
HOMEOWNER | P= | P | 07/14/2015 | need proof of potable water | TIM | TIM | | P= | P | 4992818 |
HOMEOWNER | PTO | C | 03/02/2015 | NOTE : UNFINISHED BASEMENT , NO IRRIGATION | GABE | GABE | | PTO | C | 4910527 |
HOMEOWNER | PTO | R | 02/25/2015 | field cancel | TED | TED | | PTO | R | 4908113 |
HOMEOWNER | PWO | C | 10/22/2014 | BACK FILL REQUIRED AT DWELLING TO MAKE DEPTH , POTABLE WATER CERT BY FINAL | GABE | GABE | | PWO | C | 4839727 |
LK PLUMBING LLC | PB | C | 09/17/2014 | | GABE | GABE | | PB | C | 4817638 |