PALACE HOMES, INC. | B= | C | 03/03/2015 | regraded base of wall. Is no longer more than 48" above grade. | DANE | DANE | | B= | C | 4910849 |
PALACE HOMES, INC. | B= | P | 03/02/2015 | need engineers letter for retaining wall greater than 4' -- Schedule a new Building Final when above items are complete. | BOBF | BOBF | | B= | P | 4910070 |
PALACE HOMES, INC. | BSP | P | 02/05/2015 | handrail missing at stairs in bonus room(has 4 rises)/ center window in bonus room is below 18" from floor and must be tempered/ need tempered glass behind door to master/ center garage window is within 2' of the swing of the garage service door and must be tempered/ insulate the foundation in mech. room/ lower retaining wall right of driveway is over 48" from grade to top of wall | DANE | DANE | | BSP | P | 4897608 |
PALACE HOMES, INC. | BIN | C | 11/17/2014 | | JIMA | JIMA | | BIN | C | 4854952 |
PALACE HOMES, INC. | BIN | C | 11/17/2014 | | JIMA | JIMA | | BIN | C | 4854937 |
PALACE HOMES, INC. | BFR | C | 11/12/2014 | | JOND | JOND | | BFR | C | 4852560 |
PALACE HOMES, INC. | BLA | C | 11/10/2014 | | JOND | JOND | | BLA | C | 4851515 |
PALACE HOMES, INC. | BFR | R | 11/10/2014 | hts20 at AG girder / ls90 at deck joist at rim / ? on if webs got filled behind deck joists per plan / fireblock garage brackets / ok to insulate | JOND | JOND | | BFR | R | 4851513 |
PALACE HOMES, INC. | BFR | R | 11/07/2014 | no truss calcs on site, stopped inspection | JOND | JOND | | BFR | R | 4850894 |
PALACE HOMES, INC. | BSP | P | 11/06/2014 | PLAN SPLICE by: DALEH for Mechanical | DALEH | DALEH | | BSP | P | 4849416 |
PALACE HOMES, INC. | BSP | P | 09/25/2014 | pier ok | JOND | JOND | | BSP | P | 4822675 |
PALACE HOMES, INC. | BFD | C | 09/04/2014 | soils on file / drain entire structure | JOND | JOND | | BFD | C | 4809434 |
PALACE HOMES, INC. | BFI | C | 09/04/2014 | | JOND | JOND | | BFI | C | 4809432 |
PALACE HOMES, INC. | BFN | C | 08/29/2014 | design on file / need full soils at drain / ufer rod in | JOND | JOND | | BFN | C | 4806971 |
PALACE HOMES, INC. | BFT | C | 08/29/2014 | engineer letter on file | JOND | JOND | | BFT | C | 4806970 |
PALACE HOMES, INC. | BFT | R | 08/27/2014 | already poured no paperwork on file | JOND | JOND | | BFT | R | 4805223 |
PEAK ELECTRIC INC. | E= | C | 01/16/2015 | A.C PREWIRE | MIKEC | MIKEC | | E= | C | 4886211 |
PEAK ELECTRIC INC. | ES | C | 11/06/2014 | Residential Underground: NEW 200 AMP SERVICE | MIKEC | MIKEC | | ES | C | 4849756 |
PEAK ELECTRIC INC. | ER | C | 11/06/2014 | FIREPLACE WIRED | MIKEC | MIKEC | | ER | C | 4849749 |
AIR CONCEPTS HEATING & COOLING | H= | C | 02/06/2015 | HI/LO COMBUSTION AIR, TRANSFER GRILLS INSTALLED | KEITHW | KEITHW | | H= | C | 4898185 |
AIR CONCEPTS HEATING & COOLING | H= | P | 02/05/2015 | NEED TRANSFER TO LAUNDRY ROOM, LACKS COMBUSTION AIR TO MECHANICAL ROOM FOR WATER HEATER NOTES: ALL ELSE OK, WILL SCAN DUCT LEAKAGE REPORT | KEITHW | KEITHW | | H= | P | 4897160 |
AIR CONCEPTS HEATING & COOLING | HC | C | 11/07/2014 | RELEASE METER | KEITHW | KEITHW | | HC | C | 4850243 |
AIR CONCEPTS HEATING & COOLING | HRR | C | 11/07/2014 | PLAN HAS BEEN REVISED, SUPPLY IN STORAGE HAS BEEN ELIMINATED | KEITHW | KEITHW | | HRR | C | 4850242 |
AIR CONCEPTS HEATING & COOLING | HRR | P | 10/31/2014 | MISSING SUPPLY RUN IN ATTIC STORAGE, DUCT LEAKAGE REPORT BY FINAL NOTES: DIRECT VENT FURNACE, ROUGH A/C, FINISHED BASEMENT, 6" OSA | KEITHW | KEITHW | | HRR | P | 4846277 |
DOUBLE J GAS, INC. | HI | C | 10/30/2014 | 10 PSI TEST OK NOTES: 1 1/4" GAS LINE, FURNACE, WATER HEATER, FIREPLACE, RANGE, DRYER, BBQ | KEITHW | KEITHW | | HI | C | 4845568 |
JOLLY PLUMBING & HEATING INC. | P= | C | 01/16/2015 | CORRECTIONS MADE | GABE | GABE | | P= | C | 4886747 |
JOLLY PLUMBING & HEATING INC. | P= | P | 01/14/2015 | SHOWER VALVE IN MASTER REVERSED , NOTE : FINISHED BASEMENT , PVB INSTALLED | GABE | GABE | | P= | P | 4885180 |
JOLLY PLUMBING & HEATING INC. | PTO | C | 10/31/2014 | | LEE | LEE | | PTO | C | 4846350 |
JOLLY PLUMBING & HEATING INC. | PTO | P | 10/27/2014 | NEED TO GET TUBS IN AND TEST THROUGH WASTE AND OVERFLOW . | GABE | GABE | | PTO | P | 4842879 |
JOLLY PLUMBING & HEATING INC. | PB | C | 09/17/2014 | | LEE | LEE | | PB | C | 4817788 |