HOOD CUSTOM HOMES | B= | C | 03/19/2015 | finished basement, rear attached deck | ED | ED | | B= | C | 4920116 |
HOOD CUSTOM HOMES | BLA | C | 12/02/2014 | | DALE | DALE | | BLA | C | 4863068 |
HOOD CUSTOM HOMES | BFR | C | 11/17/2014 | | DALE | DALE | | BFR | C | 4854501 |
HOOD CUSTOM HOMES | BIN | C | 11/17/2014 | | DALE | DALE | | BIN | C | 4854491 |
HOOD CUSTOM HOMES | BSP | R | 11/05/2014 | Narrow wall at garage not per plan, missing jack straps exterior nailing pattern to be 8d nails NO STAPLES / Missings e3ach end fixed window N/E corner / 1" clearence at FP b vent / FHA strap@ 3" pipesgarage common wall / pipe jack @ 3" pipe through roof / missing lateral at D-1 pts 6-15 / support stail land with straps per plan / remove posts under landing / remove float blocks throughout / Isolate monoposts / replace broken stud in basement nedroom / okay to insulate | BOBF | BOBF | | BSP | R | 4848675 |
HOOD CUSTOM HOMES | BSP | P | 10/17/2014 | porch frames ok | DALE | DALE | | BSP | P | 4836845 |
HOOD CUSTOM HOMES | BSP | P | 10/07/2014 | deck piers ok | DALE | DALE | | BSP | P | 4829903 |
HOOD CUSTOM HOMES | BSP | P | 08/28/2014 | foundation insulation okay | BOBF | BOBF | | BSP | P | 4806113 |
HOOD CUSTOM HOMES | BFD | C | 08/27/2014 | | DALE | DALE | | BFD | C | 4804638 |
HOOD CUSTOM HOMES | BFN | C | 08/27/2014 | ok per eng. / all paperwork on file / float / ufer in per eng. | DALE | DALE | | BFN | C | 4804633 |
HOOD CUSTOM HOMES | BFT | C | 08/27/2014 | ok per eng. | DALE | DALE | | BFT | C | 4804632 |
HOOD CUSTOM HOMES | BFN | P | 08/26/2014 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFN | P | 4803996 |
HOOD CUSTOM HOMES | BFT | P | 08/26/2014 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFT | P | 4803995 |
HOMERUN ELECTRONICS, INC. | E= | C | 03/19/2015 | | MATTHEW | MATTHEW | | E= | C | 4919686 |
HOMERUN ELECTRONICS, INC. | E= | C | 03/18/2015 | | MATTHEW | MATTHEW | | E= | C | 4919716 |
HOMERUN ELECTRONICS, INC. | E= | T | 03/17/2015 | PAID (REC#1251011) no disconnect for oven , # 2 AL feeders need to be derated | TOMC | TOMC | | E= | T | 4918246 |
HOMERUN ELECTRONICS, INC. | E= | R | 02/25/2015 | corrections not made | MATTHEW | MATTHEW | | E= | R | 4908314 |
HOMERUN ELECTRONICS, INC. | E= | R | 02/18/2015 | need access for spa outlets, bonding of motor and heater and gfci protection in closet needs to be dead face, need disconnect for oven, no breaker labeled dish/disp?, #2al feeder needs to be derated as per rough notes---- no a/c--------------- under cabinet lights not installed at time of final | MATTHEW | MATTHEW | | E= | R | 4904568 |
HOMERUN ELECTRONICS, INC. | ER | C | 11/14/2014 | | MATTHEW | MATTHEW | | ER | C | 4853944 |
HOMERUN ELECTRONICS, INC. | ER | R | 11/12/2014 | tc cable for well wiring needs to be installed in raceway entire length thru basement | MATTHEW | MATTHEW | | ER | R | 4852558 |
HOMERUN ELECTRONICS, INC. | ER | T | 11/04/2014 | PAID (REC#1230584): wiring to well not installed | MATTHEW | MATTHEW | | ER | T | 4848015 |
HOMERUN ELECTRONICS, INC. | ES | C | 10/30/2014 | Residential Underground: 200 AMP OK-----3-W --NEED TO SEAL METER PED---- | BRIAN | BRIAN | | ES | C | 4845529 |
HOMERUN ELECTRONICS, INC. | ER | R | 10/30/2014 | STILL NEED APPROVED WIRING METHOD FOR WELL----CONDUIT OR NM CABLE TO OUTSIDE OF HOME--------OTHER CORRECTIONS MADE | BRIAN | BRIAN | | ER | R | 4845526 |
HOMERUN ELECTRONICS, INC. | ES | R | 10/29/2014 | no ampere rating on main breaker | MATTHEW | MATTHEW | | ES | R | 4844564 |
HOMERUN ELECTRONICS, INC. | ER | R | 10/29/2014 | make up switch box by garage man door, note on laundry room floor to add outlet, well wire from well not installed, build wall for nm in kitchen floor by dining room-------------- finished basement, 1-20 ---------------------- #2al feeder will need to be derated------------ | MATTHEW | MATTHEW | | ER | R | 4844562 |
HOMERUN ELECTRONICS, INC. | EUG | C | 09/10/2014 | 3/W 4/0 AL | CRAIG | CRAIG | | EUG | C | 4813689 |
TEAM PLUMBING, INC. | H= | C | 03/05/2015 | Boiler and vent final only. Ok Note: Sealed combustion. | MARK | MARK | | H= | C | 4912460 |
BROWN'S HEATING & COOLING, INC | HC | C | 10/31/2014 | RELEASE METER | MICHAELS | MICHAELS | | HC | C | 4846250 |
BROWN'S HEATING & COOLING, INC | HRR | C | 10/31/2014 | Boiler vent ok. | MICHAELS | MICHAELS | | HRR | C | 4846247 |
TEAM PLUMBING, INC. | HWP | C | 10/29/2014 | 55# test ok. Staple up for main level. AT FINAL: check access to valved manifolds on main. | MICHAELS | MICHAELS | | HWP | C | 4844572 |
L & L GAS SHOP, LLC. | HI | C | 10/28/2014 | 10# test ok. 1 1/4" main to boiler, 3-fp, c-top, dryer, bbq. Note: boiler can not exceed 200k for system installed. | MICHAELS | MICHAELS | | HI | C | 4843501 |
BROWN'S HEATING & COOLING, INC | HRR | P | 10/28/2014 | Need boiler vent installed, rest ok. Note: radiant heat system, finished basement. | MICHAELS | MICHAELS | | HRR | P | 4843487 |
L & L GAS SHOP, LLC. | HI | R | 10/27/2014 | Low test. No boiler on site, I need to know BTU load to size pipe properly. | MARK | MARK | | HI | R | 4842171 |
TEAM PLUMBING, INC. | HWP | P | 09/10/2014 | Pressure test ok. Secured down. OK to cover. | JEFFL | JEFFL | | HWP | P | 4813418 |
TEAM PLUMBING, INC. | P= | C | 03/05/2015 | POTABLE WATER CERT TO SCANNING , NOTE : FINISHED BASEMENT , RP IN MEC IRRIGATION STUB | GABE | GABE | | P= | C | 4911797 |
HOMEOWNER | PWO | P | 11/06/2014 | need inspection on line to yard hydrant | TIM | TIM | | PWO | P | 4849856 |
TEAM PLUMBING, INC. | PTO | C | 10/17/2014 | NOTE : FINISHED BASEMENT , IRRIGATION STUB , POTABLE WATER CERT BY FINAL . BACK FLOW REQUIRED FOR YARD HYDRANT. | GABE | GABE | | PTO | C | 4836783 |
TEAM PLUMBING, INC. | PB | C | 09/04/2014 | WATER STUBBED UNDER FOOTER | GABE | GABE | | PB | C | 4809761 |