STAUFFER AND SONS CONSTRUCTION | B= | C | 02/24/2015 | | ED | ED | | B= | C | 4907640 |
STAUFFER AND SONS CONSTRUCTION | B= | R | 02/19/2015 | need instructions for wood stove | DALE | DALE | | B= | R | 4905478 |
STAUFFER AND SONS CONSTRUCTION | BLA | C | 11/03/2014 | | BOBF | BOBF | | BLA | C | 4846849 |
STAUFFER AND SONS CONSTRUCTION | BFR | C | 10/31/2014 | | BOBF | BOBF | | BFR | C | 4846295 |
STAUFFER AND SONS CONSTRUCTION | BIN | C | 10/31/2014 | | BOBF | BOBF | | BIN | C | 4846288 |
STAUFFER AND SONS CONSTRUCTION | BFR | R | 10/30/2014 | strap top plates at garage, west end | DALE | DALE | | BFR | R | 4845289 |
STAUFFER AND SONS CONSTRUCTION | BIN | R | 10/30/2014 | insulate behind electric box at garage and room above garage | DALE | DALE | | BIN | R | 4845283 |
STAUFFER AND SONS CONSTRUCTION | BFR | R | 10/24/2014 | foam and firestop / strap top plates at garage / need access to crawl space / ok to insulate | DALE | DALE | | BFR | R | 4841630 |
STAUFFER AND SONS CONSTRUCTION | BFN | C | 09/03/2014 | ok per eng. / all paperwork on file | DALE | DALE | | BFN | C | 4808861 |
STAUFFER AND SONS CONSTRUCTION | BFT | C | 09/03/2014 | ok per eng. | DALE | DALE | | BFT | C | 4808860 |
STAUFFER AND SONS CONSTRUCTION | BFD | C | 09/03/2014 | not required | DALE | DALE | | BFD | C | 4808852 |
STAUFFER AND SONS CONSTRUCTION | BFN | P | 08/27/2014 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFN | P | 4804643 |
STAUFFER AND SONS CONSTRUCTION | BFT | P | 08/27/2014 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFT | P | 4804642 |
ROWAN ELECTRIC LLC | E= | C | 01/13/2015 | | CRAIG | CRAIG | | E= | C | 4884420 |
ROWAN ELECTRIC LLC | E= | P | 12/19/2014 | need dead face for spa gfci, I need to talk to dean about spa in shower | MATTHEW | MATTHEW | | E= | P | 4875670 |
ROWAN ELECTRIC LLC | ER | C | 10/23/2014 | no mcc's, crawler | MATTHEW | MATTHEW | | ER | C | 4840710 |
ROWAN ELECTRIC LLC | ES | C | 10/16/2014 | Residential Underground: 150 amp 3/w new res. set meter | CRAIG | CRAIG | | ES | C | 4836147 |
ROWAN ELECTRIC LLC | ES | R | 10/09/2014 | need #2 main bonding jumper, house needs to be dried in | MATTHEW | MATTHEW | | ES | R | 4832020 |
ROWAN ELECTRIC LLC | EUG | C | 10/06/2014 | service lateral to home | MATTHEW | MATTHEW | | EUG | C | 4829227 |
ROWAN ELECTRIC LLC | EUG | P | 09/30/2014 | 10-3uf to well | MATTHEW | MATTHEW | | EUG | P | 4825631 |
BRUNO'S MECHANICAL INC. | H= | C | 01/28/2015 | correction made, a/c rough only, transfer openings | TED | TED | | H= | C | 4892249 |
BRUNO'S HEATING & COOLING | H= | R | 01/12/2015 | need b vent 2 feet above side wall, need secondary a/c coil drain or float switch installed (primary drain run but a/c line set not connected and condensing unit not installed ), need ladder for crawlspace access | TED | TED | | H= | R | 4883778 |
BRUNO'S HEATING & COOLING | HC | C | 10/23/2014 | RELEASE METER need 2lb system and letter | TED | TED | | HC | C | 4840655 |
BRUNO'S HEATING & COOLING | HRR | C | 10/23/2014 | by final need b vent 2 feet above side wall, note: conditioned crawlspace, a/c rough, duct design | TED | TED | | HRR | C | 4840653 |
BRUNO'S HEATING & COOLING | HRR | R | 10/22/2014 | NO DUCT DESIGN FOUND | GABE | GABE | | HRR | R | 4839686 |
BRUNO'S HEATING & COOLING | HRR | R | 10/21/2014 | no plan or permit card found | TED | TED | | HRR | R | 4838664 |
DOUBLE J GAS, INC. | HI | C | 10/17/2014 | 1'' furnace, w/h, range | TED | TED | | HI | C | 4836591 |
UNIQUE RADIANT HTG. & PLBG. | HO | C | 10/06/2014 | 60lb test on outside under ground from meter at road to house, this will need to be a 2lb system and will letter from black hills | TED | TED | | HO | C | 4828865 |
UNIQUE RADIANT HTG. & PLBG. | P= | C | 01/12/2015 | correction made | TED | TED | | P= | C | 4883798 |
UNIQUE RADIANT HTG. & PLBG. | P= | R | 01/09/2015 | need pan under water heater, note: crawlspace | TED | TED | | P= | R | 4882945 |
UNIQUE RADIANT HTG. & PLBG. | P= | P | 01/07/2015 | certificate of potable water to scanning | TED | TED | | P= | P | 4881394 |
HOMEOWNER | PWO | C | 11/04/2014 | need certificate of potable water by final | TED | TED | | PWO | C | 4848032 |
UNIQUE RADIANT HTG. & PLBG. | PTO | C | 10/23/2014 | conditioned crawlspace | TED | TED | | PTO | C | 4840656 |
HOMEOWNER | PWO | P | 10/01/2014 | LEAVE DITCH OPEN AT WELL HEAD FOR CONNECTION . NEED POTABLE WATER CERT BY FINAL . WILL NEED BACK FLOW DEVICE FOR YARD HYDRANT . | GABE | GABE | | PWO | P | 4826494 |