ELEVATION HOMES, LLC | B= | C | 02/10/2015 | All other required Final inspections are complete. (This is a computer generated result) | DALE | DALE | | B= | C | 4900294 |
ELEVATION HOMES, LLC | B= | P | 02/10/2015 | Additional Inspections Required. finished basement, deck in | DALE | DALE | | B= | P | 4900155 |
ELEVATION HOMES, LLC | B= | R | 02/10/2015 | Additional Inspections Required: External Agency Inspection HD= by HEALTHDEPT is not Completed yet (This is a computer generated result) | SYSTEM | SYSTEM | | B= | R | 4900156 |
ELEVATION HOMES, LLC | B= | R | 02/09/2015 | Additional Inspections Required. mantal to low per instructions | DALE | DALE | | B= | R | 4899390 |
ELEVATION HOMES, LLC | B= | R | 02/09/2015 | Additional Inspections Required: External Agency Inspection HD= by HEALTHDEPT is not Completed yet (This is a computer generated result) | SYSTEM | SYSTEM | | B= | R | 4899391 |
ELEVATION HOMES, LLC | BFR | C | 12/09/2014 | | DALE | DALE | | BFR | C | 4868178 |
ELEVATION HOMES, LLC | BIN | C | 12/09/2014 | | DALE | DALE | | BIN | C | 4868177 |
ELEVATION HOMES, LLC | BFR | R | 12/08/2014 | narrow braced wall has not been complete / house and garage has been insulated before inspection, can not see plates, headers, point loads, corners and joists / roll block trusses / fireblock chases / no one on site | DALE | DALE | | BFR | R | 4866949 |
ELEVATION HOMES, LLC | BLA | C | 11/26/2014 | | BOBF | BOBF | | BLA | C | 4861515 |
ELEVATION HOMES, LLC | BLA | T | 11/24/2014 | PAID (REC#1234008): not complete | DALE | DALE | | BLA | T | 4859564 |
ELEVATION HOMES, LLC | BSP | L | 10/24/2014 | front porch ok, rear lid ok / garage portial wall not nailed per plan | DALE | DALE | | BSP | L | 4841745 |
ELEVATION HOMES, LLC | BFD | C | 09/18/2014 | | DALE | DALE | | BFD | C | 4818880 |
ELEVATION HOMES, LLC | BFT | C | 09/18/2014 | ok per eng. | DALE | DALE | | BFT | C | 4818879 |
ELEVATION HOMES, LLC | BFN | C | 09/18/2014 | ok per eng. / all paperwork on file / float | DALE | DALE | | BFN | C | 4818877 |
ELEVATION HOMES, LLC | BFI | C | 09/18/2014 | | DALE | DALE | | BFI | C | 4818876 |
ELEVATION HOMES, LLC | BFN | P | 09/02/2014 | AUTHORIZED INSPECTION BY ENGINEER | MINDY | MINDY | MINDY | BFN | P | 4807542 |
ELEVATION HOMES, LLC | BFT | P | 09/02/2014 | AUTHORIZED INSPECTION BY ENGINEER | MINDY | MINDY | MINDY | BFT | P | 4807541 |
HOMERUN ELECTRONICS, INC. | E= | C | 02/03/2015 | | MATTHEW | MATTHEW | | E= | C | 4895920 |
HOMERUN ELECTRONICS, INC. | E= | R | 02/02/2015 | switches around hot tub need to be relocated and lights need to be enclosed, protection for nm needs to be installed over top of wire, remove disconnect behind drawer at oven (replace with j-box), where is gfci protection for x-mas lights located ( I couldn't get the light to go off), tandem breaker not listed for panel; replace with correct breakers | MATTHEW | MATTHEW | | E= | R | 4894994 |
HOMERUN ELECTRONICS, INC. | E= | R | 01/29/2015 | need ladder for checking x mas outlets -------------- double oven disconnect not accessible ---------- install breaker lock for oven --------------- block nm cable in mech room by furnace --------------- all outlets around hot tub needs to be remove also the feeders in side hot tub needs to be in a race way -------------------- master closet light needs to be enclosed light ------------------ arc shield for outlet in basement in front of stair ------------------ no a/c -------------- note double oven not installed at time of final | CRAIG | CRAIG | | E= | R | 4893402 |
HOMERUN ELECTRONICS, INC. | ER | C | 12/05/2014 | | MATTHEW | MATTHEW | | ER | C | 4866303 |
HOMERUN ELECTRONICS, INC. | ER | P | 12/02/2014 | well wiring not installed, no power ran to basement fireplace--------------- contractor knows he needs to call for another rough inspection when well wiring is installed | MATTHEW | MATTHEW | | ER | P | 4863402 |
HOMERUN ELECTRONICS, INC. | ES | C | 11/10/2014 | Residential Underground: 200 amp 3/w: new res---------- meter is set; need seal | MATTHEW | MATTHEW | | ES | C | 4851778 |
HOMERUN ELECTRONICS, INC. | ER | R | 11/10/2014 | install ground screws in exterior boxes, add outlet in bedroom (by garage), oven and hood circuit coiled in kitchen ceiling, need well wiring installed, does basement fireplace get wired? I need basement fireplace vent completed (nm ran in chase)------ finished basement, 6-3ser to cooking | MATTHEW | MATTHEW | | ER | R | 4851776 |
HOMERUN ELECTRONICS, INC. | EUG | C | 09/24/2014 | 4/0 al service lateral pedestal to to home | MATTHEW | MATTHEW | | EUG | C | 4822367 |
BRUNO'S MECHANICAL INC. | H= | C | 02/05/2015 | wood burning fireplace in basement, note: finished basement, no a/c (rough only) | TED | TED | | H= | C | 4897054 |
BRUNO'S HEATING & COOLING | HC | C | 12/04/2014 | RELEASE METER | MICHAELS | MICHAELS | | HC | C | 4864944 |
BRUNO'S HEATING & COOLING | HRR | C | 12/04/2014 | Corrections made. | MICHAELS | MICHAELS | | HRR | C | 4864943 |
BRUNO'S HEATING & COOLING | HRR | P | 12/02/2014 | GAS FIREPLACE VENT SHIELD TOO SHORT, 22 INCHES OF INSULATION BEING INSTALLED IN ATTIC. FYI: WOOD BURNER VENT SHIELD ALSO TOO SHORT. PLEASE LET BUILDER KNOW THAT INSULATOR NEEDS SOME WOOD ABOVE THE GAS FIREPLACE TO HOLD INSULATION IN PLACE. NOTE: FINISHED BASEMENT. OUTSIDE AIR TO FURNACE RETURN. A/C ROUGH, COIL AND LINESET. DIRECT VENT FURNACE. | NANCY | NANCY | | HRR | P | 4862979 |
DOUBLE J GAS, INC. | HI | C | 11/10/2014 | correction made | TED | TED | | HI | C | 4851629 |
DOUBLE J GAS, INC. | HI | R | 10/28/2014 | low test, note: 1 1/4'' furnace, w/h, fireplace, range (need 2lb system) | TED | TED | | HI | R | 4843504 |
DAVIS GAS SHOP INC | HO | C | 10/07/2014 | 10lb test on 2'' p.e. from road to house, 200 feet, need inside piping size for regulator at road or 2lb system ? | TED | TED | | HO | C | 4830141 |
PACIFIC PLUMBING, INCORPORATED | P= | C | 02/02/2015 | NOTE : FINISHED BASEMENT . NO IRRIGATION , POTABLE WATER CERT TO SCANNING | GABE | GABE | | P= | C | 4894729 |
HOMEOWNER | PWO | C | 12/09/2014 | | TIM | TIM | | PWO | C | 4867844 |
PACIFIC PLUMBING, INCORPORATED | PTO | C | 11/03/2014 | CORRECTIONS MADE H20 OK | GABE | GABE | | PTO | C | 4846959 |
PACIFIC PLUMBING, INCORPORATED | PTO | P | 10/31/2014 | LOW TEST ON H20 , DWV OK . NOTE : FINISHED BASEMENT . NO IRRIGATION | GABE | GABE | | PTO | P | 4846506 |
PACIFIC PLUMBING, INCORPORATED | PB | C | 09/23/2014 | | GABE | GABE | | PB | C | 4821302 |