BOB MCGRATH CONSTRUCTION LLC | B= | C | 06/19/2015 | splice for revised deck framing on file. Completes permit. | DAN | DAN | | B= | C | 4976999 |
BOB MCGRATH CONSTRUCTION LLC | BSP | T | 06/11/2015 | PAID (REC#1267444) PLAN SPLICE FEE: $50 by: JIMA for Construction: change bird aviary design | JIMA | JIMA | | BSP | T | 4971663 |
BOB MCGRATH CONSTRUCTION LLC | B= | P | 05/27/2015 | revised deck framing plan for files. and other agencies acceptance. -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982), External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977). | DAN | DAN | | B= | P | 4961502 |
BOB MCGRATH CONSTRUCTION LLC | B= | P | 05/19/2015 | . Additional Inspections Required (computer generated): External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982), External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977). | DAN | DAN | | B= | P | 4957071 |
BOB MCGRATH CONSTRUCTION LLC | BFR | C | 05/19/2015 | engineer letter on file from Michael Orsillo, #17931 for structural element of building on file. | DAN | DAN | | BFR | C | 4957068 |
BOB MCGRATH CONSTRUCTION LLC | BSP | P | 04/28/2015 | OK to move birds into cage area. Talked with Super Dave regarding needed welding and bolting letters as well as the open hole observation. | DAN | DAN | | BSP | P | 4944149 |
BOB MCGRATH CONSTRUCTION LLC | BFN | C | 04/28/2015 | | BERTW | BERTW | | BFN | C | 4944092 |
BOB MCGRATH CONSTRUCTION LLC | BFT | C | 04/28/2015 | | BERTW | BERTW | | BFT | C | 4944091 |
THE CORE ELECTRIC GROUP, LLC | BSP | T | 01/08/2015 | PAID (REC#1240246) PLAN SPLICE FEE: $50 by: DOUG for Electrical: Service revised | DOUG | DOUG | | BSP | T | 4882406 |
BOB MCGRATH CONSTRUCTION LLC | BSP | T | 12/19/2014 | PAID (REC#1238244) PLAN SPLICE FEE: $50 by: DANM for Construction: Construction Type change from II-B to V-B | DANM | DANM | | BSP | T | 4875540 |
BOB MCGRATH CONSTRUCTION LLC | BIN | R | 12/18/2014 | spoke with Jess and the construction type is going to be changed to a 5B/please correct before any inspections are called in | BERTW | BERTW | | BIN | R | 4874583 |
BOB MCGRATH CONSTRUCTION LLC | BFR | P | 12/11/2014 | steel stud framing ok/need fire resistive plywood at all walls where standard OSB is used due to type 2B construction type/need all footing and open holes reports/engineer to inspect structural steel connections and provide observation reports pending other roughs completed | BERTW | BERTW | | BFR | P | 4869804 |
BOB MCGRATH CONSTRUCTION LLC | BFD | P | 10/21/2014 | ok pending stamped open hole report-engineer inspection letter for footings needed/revised design for previous foundation comments on file | BERTW | BERTW | | BFD | P | 4838714 |
BOB MCGRATH CONSTRUCTION LLC | BFN | P | 10/10/2014 | footing observation report on file/need open hole report/drain required need drain detail-compaction results/ok to pur foundation wall/need engineering letter for details #3-3A-4 require a total of 6 horizontal #5 bars where only 4 are installed-reviewed with Jess job super | BERTW | BERTW | | BFN | P | 4832852 |
BOB MCGRATH CONSTRUCTION LLC | BFT | R | 10/02/2014 | no open hole observation field copy on site/ok to use engineer to do footing inspections only/inspection letter and stamped open hole report needed | BERTW | BERTW | | BFT | R | 4827584 |
THE CORE ELECTRIC GROUP, LLC | E= | C | 04/20/2015 | | SHELBY | SHELBY | | E= | C | 4938737 |
THE CORE ELECTRIC GROUP, LLC | E= | P | 04/08/2015 | 200 AMP PANEL AND 60 AMP PANEL FOR THE EMU BUILDING---------NEED WATER JUMPER ---RUN NEUTRAL IN SAME NIPPLE--- | BRIAN | BRIAN | | E= | P | 4931406 |
THE CORE ELECTRIC GROUP, LLC | E= | P | 03/23/2015 | NEED 1/2 "CLEARANCE AROUND CAN LIGHTS--NON IC RATED CAN NOT TOUCH WOOD---------NEED OUTSIDE --AC---BREAKER LOCKS ON ELECT HEATERS----- | BRIAN | BRIAN | | E= | P | 4921736 |
THE CORE ELECTRIC GROUP, LLC | ER | C | 12/16/2014 | | BRET | BRET | | ER | C | 4872631 |
THE CORE ELECTRIC GROUP, LLC | ER | P | 12/10/2014 | roof complete.. | BRET | BRET | | ER | P | 4868602 |
THE CORE ELECTRIC GROUP, LLC | ER | P | 12/03/2014 | roof ok grc and plates over bell boxes | BRET | BRET | | ER | P | 4863911 |
THE CORE ELECTRIC GROUP, LLC | EUG | P | 11/18/2014 | underground ok from buildings to road. | BRET | BRET | | EUG | P | 4855501 |
THE CORE ELECTRIC GROUP, LLC | EUG | P | 10/31/2014 | 2 and 3" pvc from admin to budgie building | BRET | BRET | | EUG | P | 4845879 |
DRUMMOND PLUMBING LLC | H= | C | 04/17/2015 | OK | JERRYF | JERRYF | | H= | C | 4938081 |
COLORADO SHEET METAL CO., INC. | H= | C | 04/16/2015 | TEST AND BALANCE REPORT RECEIVED | JERRYF | JERRYF | | H= | C | 4936878 |
COLORADO SHEET METAL CO., INC. | H= | P | 04/15/2015 | PARTIAL PENDING TAB REPORT - REST OK | JERRYF | JERRYF | | H= | P | 4936045 |
DRUMMOND PLUMBING LLC | HC | C | 03/27/2015 | RELEASE METER | JERRYF | JERRYF | | HC | C | 4924558 |
DRUMMOND PLUMBING LLC | HI | C | 03/27/2015 | 10# OK - PIPING PER PLAN - PER CSU THEY RAN ALL UNDERGROUND | JERRYF | JERRYF | | HI | C | 4924557 |
DRUMMOND PLUMBING LLC | HI | P | 03/26/2015 | WRONG PER MIT CALLED ALL PIPING PER PLAN IN BUDGIE AND KANGAROO BUILDING NEED CONSULT ON ALL UNDER GROUND GAS WORK COULD NOT FIND ANY INSPECTIONS IN SYSTEM - note for future inspections gate code is 6544# | JERRYF | JERRYF | | HI | P | 4924043 |
COLORADO SHEET METAL CO., INC. | HV | C | 12/22/2014 | CORRECTION MADE | JERRYF | JERRYF | | HV | C | 4876403 |
COLORADO SHEET METAL CO., INC. | HD | P | 12/19/2014 | ALL DUCT OK | JERRYF | JERRYF | | HD | P | 4875362 |
COLORADO SHEET METAL CO., INC. | HV | P | 12/19/2014 | PVC VENTS CUT ABOVE FLOOR - QUESTION WHAT IS GOING ON WHEN VENTS LEAVE THE BUILDING AT ROOF COULD NOT GET PLYWOOD OUT WINDOW FRAME | JERRYF | JERRYF | | HV | P | 4875355 |
COLORADO SHEET METAL CO., INC. | HD | P | 12/08/2014 | CONTROL PANEL HAS BEEN RELOCATED TO MAINTAIN 30" CLEARANCE - STILL NEED ALL PREVIOUS NOTES ADDRESSED FROM PREVIOUS INSPECTION | JERRYF | JERRYF | | HD | P | 4866596 |
COLORADO SHEET METAL CO., INC. | HD | P | 12/04/2014 | CONTRACTOR TO EMAIL INSTALL MANUAL FOR ERV HAVE QUESTION ON ACCESS TO CONTROL PANEL - OK FOR WRAP - STILL NEED THE FOLLOWING GAS CONTRACTOR ATTACHED - ALL EXHAUST FANS AND FLUES INSPECTED | JERRYF | JERRYF | | HD | P | 4864765 |
DRUMMOND PLUMBING LLC | P= | C | 04/13/2015 | budgie building complete | DICK | DICK | | P= | C | 4934251 |
DRUMMOND PLUMBING LLC | PTO | C | 12/17/2014 | per plan. | DICK | DICK | | PTO | C | 4873469 |
DRUMMOND PLUMBING LLC | PWO | C | 11/18/2014 | | DICK | DICK | | PWO | C | 4855619 |
DRUMMOND PLUMBING LLC | PB | C | 10/21/2014 | per plan. | DICK | DICK | | PB | C | 4838744 |