STAUFFER AND SONS CONSTRUCTION | B= | C | 03/11/2015 | finished basement, rear deck | ED | ED | | B= | C | 4915270 |
STAUFFER AND SONS CONSTRUCTION | BLA | C | 01/05/2015 | | DALE | DALE | | BLA | C | 4880153 |
STAUFFER AND SONS CONSTRUCTION | BFR | C | 12/19/2014 | | DALE | DALE | | BFR | C | 4875432 |
STAUFFER AND SONS CONSTRUCTION | BIN | C | 12/19/2014 | | DALE | DALE | | BIN | C | 4875422 |
STAUFFER AND SONS CONSTRUCTION | BFR | R | 12/17/2014 | 3 3x6 under girders and strap plates under girders / steel shim under beam / ok to insulate | DALE | DALE | | BFR | R | 4873759 |
STAUFFER AND SONS CONSTRUCTION | BFR | R | 12/16/2014 | correction not made | DALE | DALE | | BFR | R | 4872682 |
STAUFFER AND SONS CONSTRUCTION | BFR | R | 12/15/2014 | need A per plan / post and clip girder trusses per plan / strap top plate breaks / block garage door brackets / need stair straps at landing / post under basement beam pocket | DALE | DALE | | BFR | R | 4871719 |
STAUFFER AND SONS CONSTRUCTION | BSP | R | 12/04/2014 | porch piers have not been looked at | DALE | DALE | | BSP | R | 4864723 |
STAUFFER AND SONS CONSTRUCTION | BFD | C | 10/02/2014 | | DALE | DALE | | BFD | C | 4827227 |
STAUFFER AND SONS CONSTRUCTION | BFT | C | 10/02/2014 | ok per eng. | DALE | DALE | | BFT | C | 4827215 |
STAUFFER AND SONS CONSTRUCTION | BFN | C | 10/02/2014 | ok per eng. / all paperwork on file / float / ufer in per eng. | DALE | DALE | | BFN | C | 4827207 |
STAUFFER AND SONS CONSTRUCTION | BFI | C | 10/02/2014 | | DALE | DALE | | BFI | C | 4827195 |
STAUFFER AND SONS CONSTRUCTION | BFN | P | 09/16/2014 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFN | P | 4816656 |
STAUFFER AND SONS CONSTRUCTION | BFT | P | 09/16/2014 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFT | P | 4816655 |
ROWAN ELECTRIC LLC | E= | C | 03/10/2015 | | CRAIG | CRAIG | | E= | C | 4914175 |
ROWAN ELECTRIC LLC | E= | R | 03/02/2015 | uf cable to well controller needs to be protected and install nm connector for the uf cable ------------ install back porch outlet ------------- install outlet for water heater pump --------------------- in master bath ground ex fan switch -------------- install j box cover in generator -------- need paper work from owner that the generator won't hold the entire house ------------ 100 amp 4/w generator ok | CRAIG | CRAIG | | E= | R | 4910430 |
ROWAN ELECTRIC LLC | ES | C | 12/12/2014 | Residential Underground: 200 amp 3/w: new res------ meter is set and sealed | MATTHEW | MATTHEW | | ES | C | 4871073 |
ROWAN ELECTRIC LLC | ER | C | 12/12/2014 | | MATTHEW | MATTHEW | | ER | C | 4871064 |
ROWAN ELECTRIC LLC | ER | R | 12/11/2014 | add outlet in hall by office, add outlet in office by pocket door, add outlet within 6' outside wet bar, outlet under vegetable sink can't be on small appliance circuit --------------#2al sub-panel ok; will need load calc on sub-panel if 50 amp breaker is permanent, finished basement, no mcc's, #6al to cooking | MATTHEW | MATTHEW | | ER | R | 4869683 |
ROWAN ELECTRIC LLC | ES | R | 12/11/2014 | not ready | MATTHEW | MATTHEW | | ES | R | 4869682 |
ROWAN ELECTRIC LLC | ESL | C | 10/09/2014 | 1 - pvc floor box basement slab west end | TOMC | TOMC | | ESL | C | 4831971 |
ROWAN ELECTRIC LLC | EUG | P | 10/08/2014 | 10-3 uf well wire and 250 al service lateral from pedestal to home | MATTHEW | MATTHEW | | EUG | P | 4831099 |
BRUNO'S MECHANICAL INC. | H= | C | 03/05/2015 | All corrections completed, final ok. | MARK | MARK | | H= | C | 4912457 |
BRUNO'S MECHANICAL INC. | H= | P | 03/03/2015 | Large f/p on main lvl:mantle does not meet mfg requirements for clearance. see pg 24. 8 1/2" max. water heater vent connectors that are single wall, require min 6" clearance to combustibles (Including plastic piping) double wall requires 1". Lower lvl laundry closet requires min 100" make up air transfer. Rest ok. Note: 2- sealed comb furnaces. Hi/Lo grills. Line set rough only and has a fin. bsmnt. | MARK | MARK | | H= | P | 4910764 |
BRUNO'S HEATING & COOLING | HC | C | 12/11/2014 | RELEASE METER | MARK | MARK | | HC | C | 4869627 |
BRUNO'S HEATING & COOLING | HRR | C | 12/11/2014 | Fan installed, all ok | MARK | MARK | | HRR | C | 4869626 |
BRUNO'S HEATING & COOLING | HRR | P | 12/09/2014 | Missing fan in master bath. Plans show door at toilet rm. rest ok. 2- DV furn, Fin Bsmnt.no a/c has OSA. | MARK | MARK | | HRR | P | 4867831 |
DOUBLE J GAS, INC. | HI | C | 12/04/2014 | 10# test ok. 1 1/2" main to 2-furn, 2-w/h, 2-fp, range, deck heater, future fire pit on lower level. | MICHAELS | MICHAELS | | HI | C | 4864985 |
UNIQUE RADIANT HTG. & PLBG. | HO | C | 10/09/2014 | 60# test ok. existing 2" reduced to 3/4" for 2lb. system to house. Note: letter from BHE on file. BY FINAL: need reg and labeling. | MICHAELS | MICHAELS | | HO | C | 4832217 |
UNIQUE RADIANT HTG. & PLBG. | P= | C | 03/02/2015 | NOTE : FINISHED BASEMENT , PVB INSTALLED | GABE | GABE | | P= | C | 4910523 |
STAUFFER AND SONS CONSTRUCTION | PWO | C | 02/23/2015 | POTABLE WATER CERT TO SCANNING | GABE | GABE | | PWO | C | 4906735 |
UNIQUE RADIANT HTG. & PLBG. | PTO | C | 12/11/2014 | CORRECTIONS MADE | GABE | GABE | | PTO | C | 4869792 |
UNIQUE RADIANT HTG. & PLBG. | PTO | P | 12/09/2014 | wet venting is limited to bath group fixtures only | TIM | TIM | | PTO | P | 4867811 |
UNIQUE RADIANT HTG. & PLBG. | PB | C | 10/10/2014 | WATER LINES SLEEVED THROUGH FOUNDATION | GABE | GABE | | PB | C | 4832872 |
UNIQUE RADIANT HTG. & PLBG. | PWO | C | 10/09/2014 | 2 lines ( 1 from well head to house, 1 from house out to yard ) need certificate of potable water by final | TED | TED | | PWO | C | 4831830 |